Siemens SLFS and SLFSS Series – Low-Frequency Sounders Sounder-Strobes, data sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-slfs-and-slfss-series-low-frequency-sounders-sounder-strobes-data-sheet-2539816047.pdf |
---|---|
Type | |
Size | 1.44 MB |
Downloads |
Text Preview
Notification Appliances and SLFSS Series Low Frequency Sounder Strobes Indoor Wall Only Product Overview is now offering low frequency sounder strobes to its notification portfolio Formed as the SL these technologically sounder strobes meet National Fire Protection Association NFPA for recognized sleeping areas within a commercial building NFPA 72 for fire alarm NFPA 72 for Carbon Monoxide CO alarm a single device the SL can provide tones for dual applications Temporal 3 pattern T3 FIRE Temporal 4 pattern T4 CO each Model SL sounder strobe has an advanced power saving diode LED technology with three 3 modes of 520 Hertz for the sounder portion of these notification appliances T3 FIRE T4 CO Continuous coded dual sync T3 T4 control for FIRE and CO signaling to the current Siemens LFS of sounder only notification the SL of sounder strobes are produced in a sleek modern Its fitting provides high quality energy efficiency in an aesthetically low profile design that is consistent to the look of the interior of the building application inclusive trim plate makes for easy installation for retrofit projects that have backboxes installed The SL is apt for indoor wall mount Moreover the Series SLFS and SLFSS models which operate on are designed specifically for indoor wall mount applications Architect Engineer Specifications of notification Sophisticated that meets fire industry codes regulations for commercial building Compatible with the Siemens 50 point 252 and 504 point addressable fire alarm panels FACPs and with Siemens Modular FACPs Siemens PAD series of NAC extenders FireFinder XLS XLSV FACPs Siemens dual sync control DSC modules Innovative LED strobe technology provides an means for a significantly current draw Means to have existing Xenon and new LED in the same field of view 110cd Candela setting for Model SLFSS sounder strobes is labeled on the outer edge side just above the temporal adjustor Straightforward installation coupled with modern design Built in level adjustment component with grille front cover Manual index finger slide adjustor Four 4 temporal pattern settings in each appliance T3 for FIRE setting T4 for CO setting Continuous coded dual sync setting T4 for FIRE with CO Dual low frequency sounder codes in appliance Meets NFPA 72 for Fire Alarm and Monoxide UL 2034 1971 464 Listed S525 ULC S526 Listed ADA NFPA ANSI OSHA compliance Technologies Division Model SLFSSWW N Model SLFSSWR N Data Sheet 2592 inches 15.8 cm H inches 11.9 cm W inches cover 4.5 cm D and inches in total 7.16 cm D Specifications terms of composition and functionality Models SLFS and SLFSS added value to the installer for the types of applications for operation SLFSS Serieso Compact sleek low profile design Comprehensive feature list Convenient mounting options Multiple 520 Hz modes of operation Easy to adjust selection slider switch for Temporal Pattern No tools required for setting changes All Model sounder strobes include an 110cd setting Reduced current draw via cutting edge LED technology LED portion of the Siemens SL of sounder strobes meets the 20 millisecond light pulse requirements of the 2016 edition of NFPA 72 By meeting this latest requirement existing Xenon well as the new LED technology devices can now be in the same field of view In addition to the product line of Siemens SL of sounder strobes Siemens also offers an existing range of with low and high Candela settings that meet retrofit and new construction applications Siemens SL of sounder strobes have received UL ULC Listed status by attaining compatible standards with all of the Siemens fire alarm control panels FACPs and accessories that have determined to be aligned with existing Siemens strobe based appliances would include the following existing model types CH HS MTH S HQ AS SE SEF ST STH ZR and ZH Series notification appliances The regulatory listing also includes capability for installing the Siemens SL sounder strobes in the same notification and field of view with any existing Siemens Notification Appliance Xenon based strobes types of these low frequency sounders and sounder strobes are UL Listed for indoor under Standard 1971 and 464 as well as ULC S525 ULC S526 Listed Siemens SL sounder strobes also have FCC RoHS and ICES approval Technologies Division Electrical Ratings Current Draws Current Ratings Current DC in Amps 33.0 VDC 3 4 3 4 3 Temporal 4 Current Ratings Direct Current DC in Amps 33.0 VDC 110cd 3 Temporal 4 current ratings are per UL maximum RMS method max current rating is the maximum RMS current the listed voltage range 16 33V For strobes the UL max current is usually the minimum listed voltage For audible appliances the max current usually at the maximum listed voltage For unfiltered FWR ratings see installation instructions NOTES Sounder Sounder Strobes Sound Pressure Level SPL and and Sound Output Ratings dBA Reverberant per UL464 10 feet VDC 24.0 VDC 33.0 VDC 3 Temporal 4 76 85 76 85 76 85 Sound Output Ratings dBA Anechoic per ULC S525 16 3.05 meters VDC 24.0 VDC 33.0 VDC 3 4 3 4 3 Temporal 4 Code 4 CO temporal setting rated per UL2034 For dwelling use only Strobes are designed to flash at 1 flash per second minimum over their Regulated Voltage Range NFPA 72 specifies a flash rate of 1 to 2 flashes per second and guidelines the Americans with Disabilities Act ADA specify a flash rate of 1 to 3 flashes per second All Candela ratings represent minimum effective Strobe intensity based on UL 1971 The 520 Hz tone is generated within the actual notification appliance When the selector switch is set for T3 or T4 the sound pattern is also generated within the notification appliance When the selection switch is set to Continuous the product is listed for coded operations The T3 T4 pattern or any of the three other patterns pattern must be generated by the FACP according to the FIRE or CO Alarm condition initially received by the Siemens FACP Technical Data Properties SL 32 0 to 122 50 fo