Siemens SLHC, SLSC and SLHSC-series of Ceiling-Mount Horns and Horn Strobes of Notification Appliances, data sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-slhc-slsc-and-slhsc-series-of-ceiling-mount-horns-and-horn-strobes-of-notification-appliances-data-sheet-5628473910.pdf |
---|---|
Type | |
Size | 1.46 MB |
Downloads |
Text Preview
Appliances Series Horns Strobes Horn Strobes Indoor Ceiling Only Architect Engineer Specifications Product Overview as the SL Siemens is now offering horns strobes and horn strobes LED based strobes to its notification appliances portfolio the SL Siemens now offers an additional range of products with low high candela settings that makes these sophisticated notification appliances for new installs and retrofit applications light emitting diode LED strobe technology provides an energy efficient for a significantly reduced current draw strobe portion of these appliances meets the 20 millisecond light pulse duration of the 2016 edition of NFPA 72 This feature allows existing Xenon and new LED devices to be used in the same field of view a single device the SL can provide alarm signaling tones for dual All strobe models in the series feature multi candela settings 15 30 95cd on a single appliance there are two 2 modes of operation for the audible portion of these appliances T3 coded Continuous SL of horns strobes and horn strobes devices are produced in a sleek design Its structure and design provide high quality energy efficiency in an pleasing low profile design that is consistent to the look of the interior of the building application SL is exclusive to indoor ceiling mount applications The Model SLHC horn appliances work in either 12V or 24VDC whereas the Series SLSC and strobe and horn strobe devices are specifically for 24V operation Sophisticated series of notification that meets fire industry applications Compatible with the Siemens 50 point and 504 point addressable fire control panels FACPs and with Siemens Modular FACPs Siemens PAD series of NAC extenders FireFinder XLS XLSV FACPs Siemens dual sync control DSC modules Innovative LED strobe an energy efficient means a significantly reduced current Capability to have existing Xenon and LED strobes in the same field of Fewer power supplies required wire gage reduced wire runs Straightforward installation with compact modern No visible mounting screws Manual index finger adjustor Four 4 field selectable in one 1 device 30cd 75cd 95cd Faceplates ship in four distinctive types ALERT AGENT blank Two 2 audible settings in notification appliance Temporal or steady horn output High or Low setting UL 2034 1971 464 and ULC Listed S526 CSFM Approved ADA NFPA FCC ANSI OSHA compliant Model SLHSCR F Model SLSCW AL Model SLHCR N Infrastructure Building Products Data Sheet 2594 screw 3.81 cm SLHSC Serieso Horn Strobe SLHC Serieso Horn Specifications terms of composition and functionality Models SLHC SLSC and SLHSC provide added value the installer for the types of applications for operation 6.26 2.84 cm Compact sleek low profile design Comprehensive feature list Convenient mounting options Easy to adjust selection slider switch for candela settings No tools required for setting changes Multi level settings 15cd 30cd 75cd 95cd High and Low audible outputs Reduced current draw via cutting edge LED technology LED portions of the Siemens SL of strobes and horn strobes meet the 20 millisecond light pulse duration of the 2016 edition of NFPA 72 By meeting this latest requirement existing Xenon as well as the new devices can now be in the same field of view horn strobe and horn strobes ULC Listed status by attaining compatible testing standards with all of the Siemens fire alarm control panels FACPs accessories that have been determined to be aligned with existing Siemens strobe based appliances of notification appliances have Siemens would include the following existing model types CH HS MTH S HQ AS SE SEF SET ST ZR and ZH Series notification appliances The regulatory listing also includes the capability for installing the SL sounder strobes in the same notification zone and field of view with any existing Siemens Appliance Xenon based strobes these horns strobes and horn strobes models are UL Listed for indoor use under Standard 1971 and 464 as well as ULC S526 Listed The Siemens SL sounder strobes also have ADA RoHS and ICES approval Infrastructure Building Products Electrical Ratings Horn Strobes Output Current Draw Mount Horn Output Ratings UL Current Ratings HIGH dB in Amps Sound Output Ratings dBA 33.0 VDC 33.0 VDC 3 Current Ratings LOW dB in Amps 3 Horn Only Ratings Code 3 in Amps Current 24 Volts DC Range VDC 17.5 VDC 33.0 VDC Strobe Only Output Current Draw Ratings in Amps RMS Current 24 Volts DC Range 33.0 Volts DC 0.040 0.171 0.256 NOTES Strobes are designed to flash at 1 flash per second over their Regulated Voltage Range NFPA 72 specifies a flash rate of 1 to 2 and guidelines for the with Disabilities Act ADA specify flash rate of 1 to 3 flashes per second All candela ratings represent minimum Strobe intensity based on UL 1971 Technical Data General Properties Reverberant per UL464 10 feet SLHC 12VDC SLHC and SLHSC 24VDC 24.0V 33.0V 3 dBA 3 dBA dBA dBA 3 dBA 3 dBA dBA dBA Ceiling Mount Horn Output Ratings ULC Sound Output Ratings dBA Anechoic per ULCS525 16 3.05 meters SLHW 12VDC SLHW and SLHSW 24VDC 24.0V 33.0V current ratings are per UL maximum RMS method max current rating is the maximum RMS current the listed voltage range 16 33V for 24V units For audible appliances the max current is usually the maximum listed voltage 16 33V for 24V units For unfiltered FWR ratings see installation instruction 12 VDC for Model SLHC only TYPE strobe situated in a rug