Siemens SM-30 System 3 Switch Control Module, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-sm-30-system-3-switch-control-module-data-sheet-5142936807.pdf |
---|---|
Type | |
Size | 827.43 KB |
Downloads |
Text Preview
Data 3TM Control Module SM 30 Dual circuit control Placement supervised Light emitting diode LED indicators AND ENGINEER SPECIFICATIONS Single pole double throw SPDT switches UL 864 9th Edition Listed and ULC Listed FM CSFM NYC Fire Department Approved Overview System 3 switch control module Model SM 30 Siemens Fire Safety is designed to provide two SPDT manually operated switches in order to several system control functions function would include but not be limited some of the following system operations Audible signal silence for each individual audible circuit Manual activation of relays audible signals etc Engineered fire suppression system release Timer coder or municipal tie bypass Shunt type city box disconnect System disconnect Fan relay override Zone disconnect Alarm drill in system operating position the provide a SPDT contact via screw terminals yellow LED indicators mounted on the face of module one for each switch are not When the switches are manually to position the SPDT contact is reversed and yellow LED indicators are The contact rating of the switches is 0.5 at 30 VDC or 120 VAC desired circuitry is also provided within the to indicate a system Trouble condition when switch is in an abnormal position Industry Inc Technologies Division SM 30 is placement supervised and provides system Trouble signal upon removal from the unit is Underwriters Laboratories 864 9th Listed and is Factory Mutual California State Marshall and New York City Fire Department 2 manually operated switches shall be mounting in a single module assembly for purpose of opening or closing circuits in which operating functions are required module the Siemens Fire Safety Switch Control Model SM 30 shall contain two 2 SPDT one to each circuit connected to screw terminals mounted on the face of the module addition the module shall contain a yellow LED lamp for each circuit and the LED shall when the switch is thrown from a position into a system position The module shall be system via a 10 pin plug and harness and shall be operable with the main fire control panel The switch control module shall placement supervised 3TM Switch Control Module 3162 and Humidity Range SM 30 is UL 864 9th Edition Listed for indoor locations within a temperature range of 49 2 to 32 3 0 2 and a humidity of 93 2 at a temperature of 32 2 Rating Requirement switch switch each for Ordering Lb 0.45 Kg Lb 0.45 Kg Control Control Canada This marketing data sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www SBT Siemens com FIS in U S A Safety Kenview Boulevard Ontario 5E4 Canada 905 799 9937 905 799 9858 2011 sheet dated 8 05 1