Siemens SRC-8 Eight Relay Output Module, Data Sheet

File Preview
File Preview
Click below to download for free

File Data

Name siemens-src-8-eight-relay-output-module-data-sheet-0975486231.pdf
Type PDF
Size 815.96 KB
Downloads

Text Preview

s SXL EX Fire Control Panels Output Module SRC 8 AND ENGINEER SPECIFICATIONS Eight 8 Form relay outputs Two 2 Amp relay rating Relays programmable with alarms Available for Class A or Class B UL Listed ULC Listed FM CSFM and NYMEA Overview SRC 8 from Siemens Industry Fire Safety is an 8 module that provides output control for the SXL SXL EX fire alarm control panels FACPs Each relay be programmed to change state when any initiating is activated Hence any multiple zones can activate a relay while any initiating zone can alternatively any combination of relays Form relays are rated 2 Amps at 30 VDC or 120VAC can be used to operate field devices or to control a graphic annunciator SRC 8 is mounted in the SXL FACP and can be used any four 4 or 8 eight zone system SXL firmware 2.2 or higher is required to program and operate SRC 8 installation and programming is detailed in the Instructions part number 315 092968 Relay Output Module Model SRC 8 shall be available controlled output by the initiating zone Model SRC 8 contain 8 form relays which shall be to operate with any combination of zones initiating device circuit shall have the capability to be to any optional output via the system SRC 8 shall be expandable to eight 8 zones via an module Model SZE 4X which shall contain an four 4 conventional zones four 4 general relay outputs and four 4 general purpose open outputs FACP shall be a Siemens Fire Safety SXL and SXL EX utilize conventional zones be micro processor based fully field programmable The base panel shall include 4 initiating zones relay outputs for general alarm trouble events and two 2 power limited notification capable for a total of 3Amps of power for appliances FACP shall also have the following features alarm and trouble events 1 one person test protection and 24 or 60 hour battery backup FACP shall also have the following selectable features zones alarm verification by zone non latching zone alarm trouble and supervisory history coding non silenceable alarm trouble 24 hour reminder and zone output Output Module 7902 Industry Inc Technologies Division Diagram 1 The SXL Control Panel meets NFPA 72 local system requirements All wiring must be in accordance with NFPA 70 Form relay contacts are shown de energized and are suitable for resistive load only Refer to the Battery Calculations table on the next page to determine battery needs Ratings 18mA per relay Relays Amps at 30 VDC VAC resistive only for Ordering Output Module for SXL Fire Alarm Control Panel 4 Zone Expander with outputs This marketing catalog sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www SBT Siemens com FIS in U S A Safety Kenview Boulevard Ontario 5E4 Canada 905 799 9937 905 799 9858 2010 sheet dated 4 2007 1

Related Files