Siemens ST- Mass Notification Clear and Amber Lens Standalone Strobe Appliances, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-st-mass-notification-clear-and-amber-lens-standalone-strobe-appliances-data-sheet-4597263018.pdf |
---|---|
Type | |
Size | 1.65 MB |
Downloads |
Text Preview
s Sheet Safety Products Appliances Mass Notification Clear Amber Lens Standalone Strobe Appliances Application Indoor Strobe Wall Mount Strobe Ceiling Mount Retrofit Strobe Wall Mount Overview The Model ST series of strobes used in correlation to mass notification appliances are a cost way to retrofit colored lens strobe appliances Each Model ST series strobe easily mounts standard 4 backboxes or for surface mount use with Siemens Model SBL2S surface backbox Listed for use with UL2572 Listed mass notification systems Strobes are available in AMBER and CLEAR lens Devices specific to mass notification will have the word appear its cover in red or white text Strobes operate from 16 to 33VDC using filtered or Full Wave Rectified FWR voltage options for AMBER lens strobes include multi Candela models with four 4 Candela settings or 110 Candela models Strobes can be synchronized using the Siemens DSC sync modules and are utilized mass notification devices per UL 2572 The 252 504 point addressable intelligent voice communication system from Siemens FireFinder XLSM panels PAD series NAC Extenders with built in sync protocol Available with a CLEAR lens or AMBER lens option for mass notification Ceiling models are available with field selectable CLEAR lens Candela settings of 15 30 75 95cd Wall mount models are available with field selectable CLEAR lens Candela settings of 15 30 75 110cd Ceiling models are available with field selectable AMBER lens Candela settings of 11 22 56 71cd Wall mount models are available with field selectable AMBER lens Candela settings of 11 22 56 82cd Standard 1971 Listed with Occupational Safety and Health Administration OSHA 29 Part 1910.165 Industry Inc Technologies Division for MNS Series Notification Appliances 2588 appliances are Siemens Series ST Strobes or approved equals to be used UL 2572 Listed mass notification systems All inputs shall employ terminals that accept 12 to 18 AWG sizes Strobe intensity where multi Candela appliances are specified shall have field selectable and are rated per UL Standard 1971 for Ceiling models are available with field selectable CLEAR lens Candela settings of 15 30 75 95cd Wall mount models are available with field selectable CLEAR lens Candela settings of 15 30 75 110cd Ceiling models are available with field selectable AMBER lens Candela settings of 11 22 56 71cd Wall mount models are available with field selectable AMBER lens Candela settings of 11 22 56 82cd Selector switch for selecting the candela is tamper resistant The strobe portion when synchronization is required is compatible with DSC sync modules are utilized as UL 2572 Listed mass notification devices The 252 504 point addressable intelligent voice communication system from Siemens FireFinder XLSM panels PAD series NAC Extenders with built in sync protocol The strobes shall not drift out of synchronization at any time during operation Strobes feature a low current draw Strobes produce one 1 flash per second over the regulated voltage range Strobes shall revert to a non synchronized flash rate if the sync module or power supply fail to operate i e contacts remain closed Ceiling mount strobe appliances are designed for indoor flush mounting Strobe appliances shall incorporate a strobe mounting plate with a snap on grille cover Available with CLEAR lens or AMBER lens option with text on the outside of each device All strobe appliances shall listed for Applications Strobes are designed to flash at 1 flash per second minimum over their Input Voltage Range Note NFPA 72 specifies a flash rate of 1 to 2 flashes per second and ADA specify a flash rate of 1 to 3 flashes per second candela ratings represent minimum effective Strobe intensity based on UL Standard 1971 Diagram Industry Inc Technologies Division Diagram Options Refer to Siemens data sheet 2585 for the full list of mounting options E and Z are shown with an optional 6 bell Audible Speakers for ST MC RETRO MNS Strobe Plate table for other appliance combinations Notes Strobes are designed to flash at one 1 flash per second minimum over their Voltage Range All candela ratings represent minimum effective Strobe intensity based on 1638 and UL Standard 1971 All notification appliances are listed for Applications NFPA 72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second Industry Inc Technologies Division Data Series Clear Strobe Ceiling Mount Ratings AMPs RMS Current Voltage 16.0 33.0VDC 16.0 33.0VRMS 0.117 Series Clear Strobe Wall Mount Ratings AMPs Voltage 16.0 33.0VDC 16.0 33.0VRMS 0.108 RMS Current Series Amber Strobe Ceiling Mount Ratings AMPs RMS Current Voltage 33.0VDC 16.0 33.0VRMS Series Amber Strobe Wall Mount Ratings AMPs RMS Current Voltage 33.0VDC 16.0 33.0VRMS CNMA Series Used for mass notification Ratings AMPs RMS Current Voltage 16.0 33.0VDC 16.0 33.0VRMS derated approximately 25 for amber lens Candela is measured on axis Multi Candela settings have for Ordering MNS Amber Strobe multi Candela Wall Mount White MNS Amber Strobe multi Candela Ceiling Mount White S54301 Z77 A1 MNS Amber Strobe multi Candela Wall Mount White RETRO PLATE MNS Amber Strobe multi Candela Wall Mount Red MNS Amber Strobe multi Candela Ceiling Mount Red S54301 Z87 A1 MNS Amber Strobe multi Candela Wall Mount Red RETRO PLATE ST MC CNMA Amber Strobe multi Candela Wall Mount White Amber Strobe multi Candela Wall Mount White RETRO PLATE MNS Clear Strobe multi Candela Wall Mount White MNS Clear Strobe multi Candela Ceiling Mount White S54301 Z97 A1 MNS Clear Strobe multi Candela Wall Mount White RETRO PLATE MNS Clear Strobe multi Candela Wall Mount Red MNS Clear Strobe multi Candela Ceiling Mount Red S54301 Z107 A1 MNS Clear Strobe multi Candela