Siemens SXL-EX Conventional Zone Fire Alarm Control Panel, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

s Fire Alarm Control Panel Zone Fire Alarm Control Panel AND ENGINEER SPECIFICATIONS Sheet Safety Products Four 4 zones expandable to eight 8 zones Series and compatible detectors and accessories Microprocessor based control Factory programmed field configurable Two 2 Style Y notification appliance circuits 3 Amps notification and auxiliary power 24 and 60 hour battery backup Eight 8 C relay output option 220 240 VAC 50 Hz power supply option Remote serial annunciator option Sprinkler supervisory service Non silenceable bell service Alarm verification by zone One person test feature Zone output bypass feature Subsequent Alarm and Trouble with 24 hour reminders Alarm Trouble and Supervisory last event records UL 864 9th Edition Listed ULC Listed CSFM Approved Overview SXL EX from Siemens Fire Safety is a fire alarm control panel FACP with four 4 conventional zones and is to eight 8 conventional zones Model also contains features such as field power limited circuits test remote annunciation and sufficient to meet ADA requirements for signaling SXL EX is designed to meet the varied fire needs for small office buildings apartment department stores hotels strip malls or a cost efficient general purpose FACP is Asterisks shown in the second column denote Models DI 3C and PE 11TC respectively in Canada Industry Inc Technologies Division the SXL EX can be used to supply remote power for larger systems such as the MXL FACP Circuits SXL EX has four 4 conventional Style B Class zones which are typically compatible with the detector Model DI 3 the photoelectric Model PE 11 and the photo thermal Model PE 11T Siemens Fire Safety thermal and beam detectors and the MS Series of stations Please refer to the detector list in the wiring diagram for specific questions FACP 7906 Overview continued combination of 30 compatible smoke detectors can combined on a given zone Any number of thermal manual stations or other compatible direct devices may be connected to each zone All of initiating devices can be mixed on the same zone the total power requirement of the zone does exceed 9mA supervisory current Model SXL EX has additional capacity to support detector accessories as relays remote alarm lamps and audible bases zones can be programmed for many Alarm verification allows detector in sensitive areas with or without stations mixed on the zone as allowed by Manual station operation shall not be delayed verified zones Generic zone function allows the in Model SXL EX to follow the action of a fire alarm panel in the facility zones can also be bypassed as required for during construction on the premises The system expanded through the 4 four zone expander Model which has an additional four 4 initiating in addition to relays and open collector outputs Appliance Circuits SXL EX has two 2 Style Y Class B NACs each at 1.5 Amps The total power output of the panel the two 2 notification circuits and the auxiliary is limited to 3 Amps which is sufficient to provide for many applications requiring appliances to ADA specifications The SXL EX notification are power limited to reduce installation costs the addition of any hardware can be programmed for various codes These include march time simplified zone code and number of They can also be inhibited during test and functions two 2 circuits can be individually programmed as This steady operation can be used for that must continue operation after audible are silenced and Outputs SXL EX has C relays for general alarm and commands rated at 1 Amp 30VDC The 4 four zone expander module Model SZE 4X an additional four 4 general purpose relays at 2 Amps 30VDC 120VAC remote operations in the fire alarm system are from Model SZE 4X or the relay module each of which is situated within the actual SXL EX enclosure and Audible Indicators SXL EX has visible LED annunciation by zone for and trouble prompts Industry Inc Technologies Division there is a system alarm light emitting diode and a system trouble LED Supervisory zones utilize zone trouble LED flashing in sync with a system LED to indicate an abnormal system event for AC power bypass and test program mode are with the system alarm trouble and supervisory A 7 seven segment display used during testing programming functions reports a code for each trouble event Trouble conditions are also by a piezo electric sounder housed inside SXL EX annunciation is accomplished through a serial with Model LED 3 or Model LED 4 8 eight LED annunciators Models LED 3 and LED 4 display supervisory and trouble conditions for eight 8 A total of two 2 modules can be attached to system Model LED 3 comes with a black while Model LED 4 uses a white enclosure Power SXL EX contains a 1 2 Amp auxiliary power circuit is used to drive remote devices The total power for SXL EX between the auxiliary output and the two 2 is 3 Amps Supply Battery Charger power supply accepts a 120VAC 60 Hz Input or a 220 240VAC 50 Hz Input On loss of AC the system switches to battery operation indicating loss of power by flashing the AC power LED on the display capacities of 24 and 60 hours are available Controls SXL EX has four 4 switches for acknowledging supervisory and trouble conditions silencing NACs the system and for the drill function These are also used when programming the control unit Programmability and Test Functions following functions of Model SXL EX are field and are generally not programmed in the since the each unit is shipped received from the Field programming is accomplished through the and does not require the use of a computer or any tools Circuits Alarm Verification by Zone Zone Bypass Supervisory Zone Generic Zone when Model SXL EX is used to provide NACs The default mode is an alarm causing zone Appliance Circuits Non silenceable Simple Zone Coding March Time Silence Inhibit Cutoff Timers and Reminders The default mode is a steady signal Overview continued Bypass Outputs Relays Programming Zone to Output Matrix and Password Maintenance features include one person test feature lamp test search and clear of the alarm trouble and history buffer fire alarm control panel FACP shall be a Siemens Safety SXL EX shall utilize conventional zones and be microprocessor based and fully field The base panel shall include four 4 zones relays for general alarm and trouble and 2 power limited notification circuits capable of a of 3 Amps of power system shall be expandable via an expander model SZE 4X which contains an additional 4 conventional zones four 4 general purpose and four 4 general purpose open collector fire alarm system shall have the following subsequent alarm and trouble prompts one test feature brown out protection and 24 or hour battery backup Model SXL EX also has the selectable features supervisory zones verification by zone non latching zones alarm and supervisory history NAC coding alarm 24 hour reminder and zone output bypass initiating device circuit shall have the capability of mapped to any optional output via the system function FACP shall be UL ULC Listed and meet the of NFPA 72 for local fire alarm control automatic or manual service and for sprinkler and waterflow service SLX EX shall mee

Related Files