Siemens System 3 Typical Wiring Diagram, Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-system-3-typical-wiring-diagram-installation-instructions-9142603785.pdf |
---|---|
Type | |
Size | 634.76 KB |
Downloads |
Text Preview
Typical Wiring Diagram BI 35 use as Auxiliary Power Supply OF LINE RESISTOR 1 4W P N 140 820185 20 20 INCH 3 WIRE INTERCONNECT CABLE 24 24 INCH 7 WIRE INTERCONNECT CABLE 315 085062 BI 35 PLACEMENT ANYWHERE ENCLOSURE WITHIN 20 INCHES OF AND BC 35 COMMON OR AS 315 085060 INPUT 24 VDC 6.5 mA NO EXTERNAL ARE CONNECTED TERMINALS 5 6 MMB 1 ALD 2I LOOP POWER 50 60 Hz 3.5A MAX TERMINAL OF PS 35 RATING 125VAC RESISTIVE 30VDC RESISTIVE CONNECTION WIRE CONNECTION NOTE 6 SUPERVISED NOTE 6 OUTPUT VDC FULL RECTIFIED POWER SUPPLY OPERATED RATED VDC 1A NOTES 3 11 OUTPUT 24 VDC MAX TROUBLE OUTPUT 24 VDC 100mA MAX WHEN TROUBLE SUPERVISED MXL ALARM AND TROUBLE INTERFACE SEE NOTE 1 NOTE 5 PIN 3 OF P1 PLUG PIN 5 OF P1 PLUG PIN 10 OF P1 PLUG PIN 9 OF P1 PLUG PLACEMENT SUPERVISION RETURN SUPERVISED PIN 5 OF P2 ON LAST MODULE MODULE RETURN PIN 5 OF LAST IN SYSTEM 3 P1 CONNECTION USE JA 24 EQUIVALENT AND REMOVE AND ONE PLUG AS 120VAC 30VDC 3A 3 ALARM AND TROUBLE INTERFACE SEE NOTE 1 Transfer of BI 35 trouble contact will transmit a trouble to the main system Main system alarm contact will the AE 30U audible devices and deactivate battery charger When using TRI 60R or TRI B6R to to MXL MXL IQ System refer to TRI 60R Installation Instructions P N 315 092329 or TRI B6R Instructions P N 315 093315 as applicable When operating ADB X3 audibles refer to Installation Instructions P N 315 086239 Polarity shown is in mode Use only approved compatible devices Refer to audible module instructions for models BI 35 trouble relay IK1 is shown in normally energized supervisory state May use AA 30U for Class A audible device operation Other emergency supply arrangements are permissible in lieu of batteries Refer to NFPA 72 standards information To provide ground fault detection connect the PS 35 Terminal 6 shown above to System MXL MXL IQ minus supply MMB 1 2 TB 5 Terminal 9 or SMB 1 2 TB 5 Terminal 9 or PSR 1 TB3 Terminal 2 to System 3 DC minus supply Terminal 6 of the System 3 PS 35 System input to BI 35 activates audible circuits and deactivates battery charger normally zero volts to activate audible circuits and deactivate battery charger All equipment except notification appliances must be in the same enclosure Mount in EB series enclosure A maximum of 10 AE 30 modules can be connected to the BI 35 module Note that only 9 amps is from the PS 35 AE 30U rated Special Application 16 32V unfiltered fullwave rectified 0.5mA max Supervisory 1.5A Alarm Note For a list of notification appliances refer to P N 315 096363 For synchronized use of a DSC or DSC W is required Industry Inc Technologies Division Park NJ Building Technologies Ltd Safety Security Products Kenview Boulevard Ontario L6T 5E4 Canada 315 086257 10 TB positions 1 10 are power limited WIRE INSTRUCTIONS P N 315 085099 P N 315 085061 7 NOTES 9 AND 10 OF LINE RESISTOR ASSEMBLY 1 2W P N 140 049898 INDICATING DEVICE CIRCUIT 24 VDC AUDIBLE DEVICES SEE NOTES 2 AND 4 OF LINE RESISTOR ASSEMBLY 1 2W P N 140 049898 Wiring Diagram PLUG 3 AMP POWER SUPPLY WIRE CABLE INSTALLATION BC 35 315 085060 20 315 086257 10 A 315 085062 24 315 085062 POWER VAC 50 60 HZ 3.2A MAX OUTPUT VDC 9 AMPS WAVE RECTIFIED CONDUCTOR CABLE P N 500 695393 TO PIN 1 OF P2 PLUG TO PIN 5 OF P2 PLUG TO PIN 10 OF P2 PLUG TO PIN 9 OF P2 PLUG MODULE RETURN PIN 5 OF LAST IN SYSTEM 3 PS 35 TERM 5 BI 35 TERM 7 3A 3 ALARM AND TROUBLE INTERFACE SEE NOTE 1 OF LINE RESISTOR 1 4W P N 140 820185 MMB 1 ALD 2I LOOP TERMINAL OF PS 35 RATING 125VAC RESISTIVE 30VDC RESISTIVE MXL ALARM AND TROUBLE INTERFACE SEE NOTE 1 OUTPUT VDC 9A WAVE RECTIFIED POWER VAC 50 60 HZ 3.2A MAX OUTPUT VDC 9A WAVE RECTIFIED POWER VAC 50 60 HZ 3.2A MAX Transfer of BI 35 trouble contact will transmit a trouble to the main system and deactivate battery charger When using TRI 60R or TRI B6R to interface to MXL MXL IQ System refer to TRI 60R Installation P N 315 092329 or TRI B6R Installation Instructions P N 315 093315 as applicable BI 35 trouble relay IK1 is shown in normally energized supervisory state To provide ground fault protection connect the PS 35 Terminal 6 shown above to System MXL DC minus supply MMB 1 2 TB 5 Terminal 9 or SMB 1 2 TB 5 Terminal 9 or PSR 1 TB3 Terminal 2 or to 3 DC minus supply Terminal 6 of the System 3 PS 35 System input to BI 35 activates audible circuits and deactivates battery charger normally zero volts high to deactivate the battery charger The calculated loading of the common battery for the 3 combined PS 35s must not exceed the maximum listed ratings for a single battery as shown in the BC 35 Installation Instructions P N 315 085060 TB positions 1 10 are power limited 315 086257 10