Siemens TPR-300 Polarity Reversal and City Tie Module Installation
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-tpr-300-polarity-reversal-and-city-tie-module-installation-7812056349.pdf |
---|---|
Type | |
Size | 1.36 MB |
Downloads |
Text Preview
TPR 300 Polarity Reversal and City Tie Module Installation hole for screws hole for screws 1 TPR 300 Polarity Reversal and City Tie Module the TPR 300 to the FACP following table describes which connection to attach the TPR 300 to on each FACP CONNECTS TO CONNNECTION Used Used 1 TPR 300 P1 Connections to different FACP Alarm Transmit signal to the TPR 300 can be programmed to turn OFF when signal silence is active This allows the Tie Box to be manually reset On subsequent alarms the silenceable signals will resound and the City Tie Box will be Trouble Transmit signal to the TPR 300 can be programmed to delay AC power fail 0 1 2 or 3 hours if this the only system trouble Kenview Blvd Ont L6T 5E4 905 799 9937 905 799 9858 Industry Inc Fernwood Florham Park 07932 U S A 973 593 2600 905 547 6902 Rev 3 May 2013 Reversal and City Tie Module Wiring TPR 300 Polarity Reversal and City Tie Module if used as shown in Figure 2 below Power Limited cable type FPL or FPLP must be used For USA installation the installer must use Atlantic Scientific Tel 407 725 8000 Model Protective Device or similar UL Listed QVRG secondary protector as shown For use in Canada the Protective is not required but still recommended TIE LOCAL ENERGY 24VDC FILTERED COIL 14 Ohms 270mA RIPPLE line resistance 20 Ohms LIMITED REVERSAL ALARM OPEN AT 3.5mA MAX SHORT LIMITED REVERSAL SUPV OPEN AT 3.5mA MAX SHORT TO NEMA STANDARD INTENDED FOR TO POLARITY CIRCUIT OF A REMOTE RECEIVING UNIT HAVING RATINGS RAIL CONNECTION EARTH GROUND LIMITED A SHORTING WIRE THE CITY TIE IS USED RAIL CONNECTION EARTH GROUND LIMITED CABLE TYPE FPL or FPLP MUST BE USED TPR 300 PROTECTORS 2 TPR 300 Polarity Reversal and City Tie Wiring Specifications Tie Power Limited Reversal Power Limited Reversal Supv Terminal Reversal Alarm Terminal Consumption DC unfiltered DC open DC supervisory DC normal mA max DC at 3.5mA 0V trouble DC alarm city tie in use ohms trip coil 8.5mA max shorted 0V trouble Rev 3 May 2013 the TPR 300 to a Keltron 95M3158 Transmitter Ground Unit Transmitter in same room at a distance of no than 20 feet to Main Board FACP Series FACP 3 Connecting the TPR 300 to a Keltron 95M3158 Transmitter Rev 3 May 2013 Fernwood Florham Park NJ 07932 U S A 973 593 2600 Fax 908 547 6902