Siemens TRI-B6M Intelligent Device Interface Module, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-tri-b6m-intelligent-device-interface-module-data-sheet-2615047983.pdf |
---|---|
Type | |
Size | 865.60 KB |
Downloads |
Text Preview
Sheet Safety Security Products Interface Module use with FireFinder XLS and MXL Panels TRI B6M Interfaces and supervises normally open N O Fire Detection or AND ENGINEER SPECIFICATIONS closed N C contacts Security Detection Compact size allows mounting in single gang box behind equipment Innovative technology supports comprehensive system and communication SensorLINK programmer tester FPI 32 upgrade kit programs and device address as well as tests device functionality Electronic address programming is easier and more dependable Microcomputer chip technology Dynamic supervision Two wire operation UL Listed ULC Listed and NYCFD Approved Overview Intelligent Interface Module Model TRI B6M Siemens Fire Safety is designed to provide means of interfacing direct shorting devices to FireFinder XLS panel Model MLC or the MXL Model ALD loop circuit TRI B6M provides the most advanced of address programming and supervision combined with sophisticated fire alarm control FACP communication Each Model TRI module incorporates microcomputer chip with sophisticated bi directional capabilities to either the FireFinder or MXL FACP The device microcomputer has the capacity of storing in memory information as well as important data TRI B6M is designed to monitor a N O or dry contact and reports the contact status either the FireFinder XLS or MXL panel technology from Siemens Fire Safety each Model TRI B6M module to be and tested via the SensorLINK Tester Model FPI 32 upgrade kit Industry Inc Technologies Division upgrade kit is a compact portable and menu accessory that makes programming and testing interface device faster easier and more than previous methods FPI 32 eliminates the need for mechanical mechanisms such as program jumpers switches or rotary dials since the upgrade kit sets the interface address into the non memory of Model TRI B6M microcomputer corrosion and other conditions that mechanical addressing mechanisms are no a cause for concern Model TRI B6M is to the FPI 32 upgrade kit with the cable provided with the tester This cable Part No 110 694927 utilizes two alligator clip connectors to attach to each Interface Module TRI B6M is fully compatible on the same circuit all intelligent Model IL and Model ID 60 Series Model MSI Series addressable manual or any other addressable intelligent modules as Model CZM or Model ICP Interface Module 6170 and Humidity Range TRI B6M is UL 864 9th Edition Listed for indoor locations within a temperature range of 120 3 to 32 3 0 2 and a relative humidity of 93 2 at a temperature of 90 3 for Ordering Weight 500 894546 500 894993 Interface B6 Chip Interface B6 Chip only Intelligent Interface Module Model TRI B6M incorporate a custom microprocessor based circuit that provides communication its compatible control panel Model TRI B6M be a Siemens Fire Safety module that shall compatible with FireFinder XLS or MXL FACP TRI B6M shall provide the means of direct shorting devices to the circuits and shall report the contact to the FireFinder XLS or MXL FACP TRI B6M shall be UL and ULC Listed and TRI series devices shall be listed and have capability of interfacing N C security to the FireFinder XLS or MXL FACP per 1076 addressable interface module shall be supervised and uniquely identifiable the control panel addressable interface module address shall programmed with the use of a portable accessory The portable accessory shall be a Siemens Fire Programmer Tester FPI 32 upgrade kit portable programming accessory shall be driven once the desired address is the programmer shall set and verify the The programming accessory shall also capable for testing the functionality of Model addressable interface module address shall be set by electronic means No mechanical such as programming pins DIP switches or dials shall be required TRI B6M shall be compatible on the same with other intelligent Model IL and Model Series detectors Model TRI Series interfaces Model MSI Series manual stations or any other intelligent modules such as Model or Model ICP Industry Inc Technologies Division Diagram Point Installation WARNING CIRCUITS INTENDED FOR 24 HOUR ALARM MONITORING ONLY 1076 requires a Model HTSW 1 tamper switch a Model TSP 40A printer A Communication command that is triggered with a Model TRI device configured for a Security prompt will in the Security Alarm and Communication commands to activate installing a Model TRI Series device into the programming tool or into the MXL panel CSGM be sure to set the device usage to the command When setting the device using the FPI 32 upgrade kit select the alarm causing input only one 1 switch per Model TRI Series As part of the normal installation practice Model TRI Series device must be functionally including testing the supervision through end of line resistor are the sequential steps required for each TRI Series device installation Open the end of line resistor Check that the system annunciates the programmed message Return the resistor to its proper connection Change the state of the switch to confirm that the programmed response is executed Return the switch to the Normal state Industry Inc Technologies Division This marketing data sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www usa Siemens com Fire in U S A Safety Kenview Boulevard Ontario 5E4 Canada 905 799 9937 905 799 9858 2012 sheet dated 1 11