Siemens VESDA CPY-HLI Intelligent Interface, Data Sheet

File Preview
File Preview
Click below to download for free

File Data

Name siemens-vesda-cpy-hli-intelligent-interface-data-sheet-3956481702.pdf
Type PDF
Size 837.04 KB
Downloads

Text Preview

Catalog Series Interface CPY HLI Supports a VESDA network with up to 31 VESDA detectors for continuous operation Allows for a single point of alarm and trouble reset commands at the MXL IQ panel Model XL IQ will visually and audibly display Alert and Action alarms of the VESDA network as Trouble pre alarms commands and will visually and audibly display Fire 1 as a latching Alarm event Provides for graphical displays of smoke levels and airflow levels on the Model MXL IQ LCD display Supervised connection between Models CPY HLI and NIM 1W Surfaced mounted within 6 feet of the Model MXL IQ enclosure fixed conduit Installer only required to utilize one 1 communication cable to connect VESDA network with Model MXL IQ Overview High Level Communication Interface Model from Siemens Fire Safety is a bi directional module that interfaces Siemens Safety Model MXL IQ control panel with a detection network Model CPY HLI converts communication language to a language can be understood between the VESDA and the MXL IQ panel utilizes an RS 485 communication network which Model CPY HLI converts this signal to the communication that is needed for Model to communicate with Model NIM 1W in a MXL IQ panel Model MXL IQ will 31 VESDA detectors Standard or Scanner and will be notified of alarm and trouble by address VESDA zone matches MXL IQ address VESDA Zone 1 is mapped to MXL IQ address 00X 001 is device loop number Industry Inc Technologies Division RS 232 connection between Models MXL IQ and CPY HLI Required for AT T installations UL 864 9th Edition Listed ULC Listed CSFM and NYMEA Approved VESDA detectors utilize four 4 indicators of alarm action fire 1 and fire 2 commands Alert and Action are indicated by Model MXL IQ as commands and Fire 1 is indicated by Model as an alarm event All VESDA trouble are indicated by Model MXL IQ by zone dimensions for Model CPY HLI are 9.5 length 7.3 width by 2.167 depth The enclosure must mounted on the wall within 6 feet of the Model enclosure A cable Model CPY HLICABLE is to connect Model NIM 1W with Model CPY The cable is included with Model CPY HLI CPY HLI cable must be installed within rigid and Models CPY HLI and MXL IQ must within the same room CPY HLI is connected to the VESDA network a RS 485 connection already utilized by the network Intelligent Interface 1176 for Ordering VESDA Intelligent includes fully boards mounted in enclosure and is shipped the appropriate cable Replacement cable for Model MXL IQ connection Overview continued CPY HLI can be located up to 4000 ft from VESDA detector in which it is connected All connections between Models MXL IQ and as well as the VESDA network are MXL IQ provides many additional features to VESDA network such as a single point reset displays and history printing capabilities single point reset allows the VESDA network and or alarm commands to be reset from MXL IQ rather than at each individual LCD display for Model MXL IQ provides a illustration by address zone of either the networks smoke levels or airflow levels Model MXL IQ provides the added capability printing all alarm and trouble events as well as level and airflow alarm trip points for each detector zone Diagram Shown In Inches This marketing catalog sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www SBT Siemens com FIS in U S A Safety Kenview Boulevard Ontario 5E4 Canada 905 799 9937 905 799 9858 2010 sheet dated 1 03 1

Related Files