Siemens XCI2001-U1 Cerberus PRO Releasing Module, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-xci2001-u1-cerberus-pro-releasing-module-data-sheet-8360914725.pdf |
---|---|
Type | |
Size | 855.54 KB |
Downloads |
Text Preview
PRO Module XCI2001 U1 Architect Engineer Specifications Provides releasing for pre deluge sprinkler as as Sinorix clean agent Product Overview Releasing Module Model XCI2001 U1 is an optional module that is connected to peripheral boards Models FCI2016 U1 and FCI2017 U1 providing optional capabilities to the 252 point and 504 point addressable fire systems Double interlock function pre action systems each releasing module protects the releasing circuits from accidental during maintenance Two 2 releasing zones Releasing valve monitoring Built in manual disconnect service maintenance Monitors for open line and conditions Suitable for use with indoor UL 864 10th Edition Listed Listed FM CSFM and NYC Fire Approved XCI2001 U1 supports activation of releasing valves in pre action deluge systems double interlock pre action systems or Sinorix Engineered Fire Suppression Activation can be event controlled or performed by addressable stations installed on a Model FC922 or Model FC924 Cerberus PRO fire alarm control panel the releasing module contains an integral manual disconnect switch for circuits 1 end of line resistor Model REL EOL is used specifically for Class A wiring and 2 Model REL EOL resistors must be used for Class B wiring can be accomplished via cross zoning of automatic detectors or manual activation pre discharge countdown timer is available for display at the operating units Model Model XCI2001 U1 is FM 3010 CSFM 7165 0067 0259 and FDNY Approved and Humidity Range XCI2001 U1 is UL 864 10th Edition and ULC S527 Listed for indoor dry locations a temperature range of 120 3 49 2 to 32 3 0 2 and a relative of 93 2 at a temperature of 90 3 32 2 Infrastructure Building Products usa siemens com fire Data Sheet 9809 Data Ratings current 24VDC per circuit current 24VDC per circuit Terminals terminal blocks 18 American Wire cable AWG Properties W H 6 cm x 15.2 cm Lbs 590g for Ordering on 252 point 504 point Releasing Module systems End Of Line Documentation Sheet PRO System Operating Unit FCM2018 U3 PRO Operating Unit with LEDs FCM2019 U3 Board on 252 point addressable FACPs FCI2016 U1 Board on 504 point addressable FACPs FCI2017 U1 Solenoids For a system operating unit with LEDs used in ULC installations Model FCM2035 U3 must be ordered and See Datasheet 9801 9801C for more information To see the comprehensive list of solenoids compatible these products please review the Solenoid Compatibility on document listed above NOTICE The information contained in this data sheet document is intended only a summary and is subject to change without notice product s described here has have a specific instruction sheet s cover various technical limitation and liability information of install type instruction sheets as well as the General Product and Limitations document which also contains important data provided with the product and are available from the Manufacturer contained in the aforesaid type of documentation should be consulted a fire safety professional before specifying or using the product further questions or assistance concerning problems that might arise relative to the functioning of the equipment please contact Manufacturer PRO Industry Inc Infrastructure Building Products Fernwood Road Florham Park NJ 07932 973 593 2600 2021 6