Siemens XDACT Desigo Fire Safety Modular Communications Transmitter, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-xdact-desigo-fire-safety-modular-communications-transmitter-data-sheet-2509687431.pdf |
---|---|
Type | |
Size | 990.84 KB |
Downloads |
Text Preview
Fire Safety system XDACT Assembly XDACT ASSY use with Model FCA2015 U1 Engineer Specifications Holds the dialer used on Desigo Fire Modular panels FACPs Product Overview as a component in Siemens Desigo Fire Safety Modular control panels the Assembly Model XDACT ASSY is the blank plate used for holding the Digital Alarm Communication Transmitter DACT Model FCA2015 U1 For use with a Siemens Model digital alarm transmitter DACT Compatible with current and GSM dialers Accounts can either Ademco ID or SIA One 1 Model XDACT ASSY as as one 1 Model FCA2015 U1 are required for purchase A Model XDACT and power of one plate and one Configured directly from the custom programming tool Zeus D Global or local configuration For global configurations via Zeus the Model XDACT ASSY must be in the Global OI cabinet Firmware upgradeable similar to Desigo Fire Safety modules Initial upgrade required Adjustable connection test timing Mounts on the inner door of a Desigo Safety Modular system panel to the OI UL864 CAN ULC S576 Listed Technologies Division XDACT ASSY can be mounted on all Desigo Fire Safety Modular systemCAB enclosures The XDACT assembly vertically mounts on the back left hand of an inner door of a Desigo Fire Safety Modular system panel adjacent to a Interface OI Each XDACT assembly plate is only available in black turn the DACT mounts onto the XDACT assembly face first with its back end facing outward a DACT can be configured globally or locally a Model XDACT ASSY be located in the Global OI cabinet for global configurations communication protocols on a given DACT module include DCS 8 DCS 20 Ademco Contact ID Temperature and Humidity Range XDACT ASSY as well as Model FCA2015 U1 UL 864 9th Edition Listed for indoor dry locations a temperature range of 120 3 49 2 32 3 0 2 and a relative humidity of 93 2 at a temperature of 90 3 32 2 XDACT ASSY Assembly Assembly 7361 Details for Ordering TYPE S54400 A63 A1 Fire Safety Modular XDACT Assembly One 1 XDACT assembly XDACT ASSY One 1 power cable connection between a FCA2015 U1 and Operator Interface OI Alarm Key for FCM2041 U2 Operator Interface Technical Data W H D PROPERTIES 14.81 0.37 cm 37.6 cm 0.9 cm 1.8 lbs 817g Compatibilities of Compatible Alarm Communicators ModelXDACT ASSY via the use of a Model dialer can utilize different communication including Internet Protocol IP and on Siemens fire alarm control panels in to connect to compatible central station receivers off premises monitoring Mobile Station Receiver Compatible Table following table shows a of central station that are compatible with Desigo Modular FACPs DCS 8 DCS 20 ID KNIGHT Multiple central station receivers are compatible with Fire Safety Modular control panels Although table above illustrates central station receivers that been verified by Siemens additional receivers and can also be used with each of these systems After completing the installation Transmitter Model FCA2015 U1 and Station Receiver must be tested verified NOTICE The information contained in this data sheet document is intended only a summary and is subject to change without notice product s described here has have a specific instruction sheet s cover various technical limitation and liability information of install type instruction sheets as well as the General Product and Limitations document which also contains important data provided with the product and are available from the Manufacturer contained in the aforesaid type of documentation should be consulted a fire safety professional before specifying or using the product further questions or assistance concerning problems that might arise relative to the functioning of the equipment please contact Manufacturer Fire Safety Industry Inc Technologies Division Fernwood Road Florham Park NJ 07932 973 593 2600 2017 New Issue 0