Siemens XEA-1 2 and XED-1 XED-2 Adapter Plate and Door, Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

INTRODUCTION OF MXL SYSTEM Instructions XEA 1 2 and XED 1 2 Plate and Door the Models XEA 1 2 and XED 1 2 to existing installed XL3 backboxes EBX 1 or EBX 2 to accommodate System hardware With this conversion the maximum size that can be used in the is 31AH If a larger battery required use a BB 55 battery box convert an EBX 1 2 backbox from an XL3 to an MXL System you must first the XL3 and then assemble the This two part procedure is described in below OF XL3 SYSTEM all system power battery and then AC Remove the front panel door and save the Disconnect the input and output power from the line filter Mark the input power wires Remove the filter from the backbox Disconnect the wiring to all modules and identify wires Remove the PSX MBX 1 s and batteries the backbox and save the hardware Place the adapter plate either the XEA 1 or onto the studs in the backbox Install washers nuts that were removed during disassembly procedure on the third row studs from the top of the enclosure on both left and right sides There are two L shaped brackets One bracket has a magnet in the top One bracket has 3 tapped holes in the top Both brackets have slots in the lower Place the L shaped bracket with the magnet in top flange on the left side of the backbox the adapter plate See Figure 1 Position the 2 slots in the lower flange the center of the backbox and place onto the two top left studs of the the washers nuts making sure that bracket slots are against the studs tightening the nuts Place the L shaped bracket with three tapped in top flange on the right side of the over the adapter plate See Figure 1 Position the 2 slots in lower flange facing center of the backbox and place them the two top right studs of the backbox the washers nuts making sure that bracket slots are against the studs tightening the nuts Industry Inc Technologies Division Park NJ 315 093608 4 Building Technologies Ltd Safety Security Products Kenview Boulevard Ontario 5E4 Canada Mount the MKB 4 Refer to Figure 1 Mount the enclosure door Model XED 1 or Place the MKB 4 on the right bracket the hardware supplied with the Do not tighten the screws at this Adjust the position of the MKB 4 so that module opens smoothly and closes against the magnet Tighten the screws the washers nuts onto the remainding that project through the adapter plate Use the hardware saved from the procedure to secure the door to backbox Place the MXL configuration label P N 575 over the existing configuration label the MKB 4 the MXL modules and batteries in the Wire the modules in accordance their respective installation instructions To power up the system connect the AC and then the battery the MKB 4 Annunciator Keyboard in the EBX 1 2 Backbox 1 315 093608 4

Related Files