Siemens XTRI-D, XTRI-R, XTRI-S Intelligent Device Interface Modules, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

and Detection Initiating Devices Device Interface Modules XTRI D XTRI R XTRI S Engineer Specifications Siemens ISOtechnology Provides Class X operation wiring NFPA 72 SLC Product Overview Siemens Fire Safety XTRI series Intelligent Interface Modules are designed to the means of interfacing direct shorting devices to the fire alarm control FACP SLC All modules take up one 1 address on the loop Supports 252 ISOtechnology ready per loop and in mixed mode to 30 devices between isolated Dual input on Model XTRI D via single address Integral single pole double throw relay on Model XTRI R Up to 4 Amps Low current draw Polarity insensitive in non isolation via SureWire technology Modern technology supports system and communication Multi color light emitting diode LED system status GREEN AMBER RED Mounts in a 4 inch 10.2 cm square 2 5.7 cm deep single gang or back box Non obstructive front end access to port and wiring terminals Device Programmer Test Unit programs verifies address as well as tests functionality Restriction of Hazardous Substances compliant UL864 UL2572 UL2017 Listed CAN ULC CAN ULC S576 Listed File S24304 Vol 3 XTRI series interface module provides the ISOtechnology feature dual isolation meeting NFPA 72 Class X Style 7 wiring requirements Up 252 isolators per loop and up to 30 devices between isolators wired in polarity mode Additionally the devices between isolators can either be the more contemporary detection devices Specifications Siemens Fire Safety XTRI series Intelligent Interface Modules are available in 3 individual types One 1 Dual Input XTRI D Two 2 Single Inputs XTRI R with relay XTRI S single input versions are each designed to monitor a normally N O or N C normally closed dry contact XTRI R XTRI S incorporates ISOtechnology the configurable built in dual function Additionally an XTRI series interface module supports NFPA 72 X Style 7 survivability requirements for shorts while providing reliable alarm to the Siemens FACP The isolation feature found on the XTRI series Interface Modules gives information as to the location of the fault When short occurs the panel can identify the fault automatically and the module the short location in front of the device or behind the device the built in isolators improve the diagnostics and location of the problem a short modules are configurable by a Siemens compatible FACP or panels in an polarity sensitive or non isolator polarity insensitive mode When a XTRI interface module is configured as an isolator that module has the capacity of as both an in out device as well as an isolator troubleshooting is provided by compatible by identifying when a XTRI series interface is configured as an isolator but is wired in a polarity insensitive mode Model XTRI series device has a multi color LED flashes when GREEN operating in Normal mode if the unit is in a Trouble condition and RED indicate a change of status XTRI S single input interface module can only monitor report the status of a N O or N C contact XTRI R XTRI S Device Module Data Sheet 6167 Infrastructure Building Products usa siemens com fire XTRI D XTRI R XTRI S Device Module Specifications continued Data XTRI R the use of an addressable C relay the XTRI R relay and contact device input are at the same address The relay and input can be controlled as a separate function from a compatible FACP The relay is typically used control or shunting of external equipment is XTRI D XTRI D is a dual input module that is designed supervise and monitor two 2 sets of dry contacts XTRI D only requires one 1 address but independently to each input Model XTRI D ideal for monitoring a water flow switch and its valve tamper switch 4 10.2 cm box 2 1 8 cm back box 3.5 8.9 cm double back box 5 12.7 cm switch supplied Each interface module directly to a user switchbox electrical boxes seen are supplied by others XTRI D XTRI R and XTRI S directly onto a 4 inch 10.2 cm 2 5.7 cm box back or to a user supplied double gang 3 deep back box 5 12.7 cm square off white faceplate included in each shipment of a Siemens XTRI series module Operation Programmer Test Unit Fire Safety innovative technology allows Model XTRI series intelligent interface modules to be programmed via the field device programmer test unit Model DPU which is a compact portable and menu driven accessory for programming and testing Siemens peripheral modules and devices promptly and reliably For instance the technician selects the accessory program mode and enters the desired address XTRI series interface module is connected to Model DPU with the programming cable provided with the tester Since the XTRI series of interface modules are advanced initiating devices the latest Model DPU firmware update is required DPU eliminates the need for cumbersome unreliable mechanical programming methods e g dials and rotary and reduces installation and service costs by electronically programming and testing the module prior to When set in test mode Model DPU will perform a series of diagnostic tests without altering the address or stored data allowing technicians to determine if the module is operating properly field device programmer test unit operates on AC power or rechargeable batteries providing flexibility and in the programming testing of fire safety equipment from practically any location Additionally with the use a Model DPU unit there is no longer a cause for concern with any vibration corrosion and other deteriorating conditions could negatively affect any electro mechanical addressing mechanism X modules may be used along with Model H intelligent detectors Model HMS addressable stations or any other H addressable intelligent module e g Model HZM or Model HCP Additionally the X modules are compatible with all Desigo and Cerberus Pro detectors and peripherals of the same circuit X H devices on the same loop is mostly permitted but there are exceptions Models HLIM isolation and SBGA 34 audible base cannot be used with X devices on the same loop Infrastructure Building Products usa siemens com fire and Humidity Range XTRI D XTRI R XTRI S intelligent interface modules are UL Listed ULC Listed Environmental operating conditions each interface module is 32 0 to 120 49 with a relative humidity of no greater than 95 non condensing Indicators supervisor y operation

Related Files