Siemens XTRI-M Intelligent Interface (Mini) Module, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-xtri-m-intelligent-interface-mini-module-data-sheet-5824037169.pdf |
---|---|
Type | |
Size | 952.64 KB |
Downloads |
Text Preview
and Detection Devices Device Device Interface Mini Module XTRI M Architect Engineer Specifications Siemens ISOtechnology Provides Class meeting NFPA 72 SLC wiring requirements Product Overview Siemens Fire Safety Intelligent Interface Module Model XTRI M is designed provide the means of interfacing direct shorting devices to the fire alarm control FACP loop circuit The module uses one 1 address on the loop Supports 252 ISOtechnology devices per loop and in mode up to 30 devices isolated devices Low current draw Restriction of Hazardous RoHS compliant Compact size allows mounting in box behind equipment Supervises and controls open N O and closed N C contacts Polarity insensitive in non isolation via SureWire technology Modern technology comprehensive and interface Device Programmer Test Unit and verifies address as well tests device functionality UL864 UL2572 UL2017 Listed CAN ULC S576 Listed File S24304 Vol 3 XTRI series interface module provides the ISOtechnology feature dual isolation meeting NFPA 72 Class X Style 7 wiring requirements to 252 isolation ready devices per loop and in mixed mode a maximum of 30 devices between isolated devices wired in polarity insensitive mode the devices between isolators can either be or the more detection devices XTRI M is designed to supervise and control a N O or N C contact and the contact status to the FACP Specifications XTRI M incorporates ISOtechnology the configurable built in dual feature Additionally an XTRI series interface module supports True Class operation meeting current NFPA 72 SLC performance requirements for short while providing reliable alarm communication with the Siemens FACP isolation feature on a Model XTRI M Mini Module provides the location of the fault command sent to the FACP When a short occurs the panel can the fault automatically Concurrently the module recognizes the location the fault in front of the device or behind the device ISOtechnology protects and maintains system while also significantly improving the capability to allow simple location of the including a wire to wire short Mini Module is configurable by the FACP in an polarity sensitive or non isolator polarity mode When a XTRI M module is configured an may serve a dual purpose by functioning as an input output device an isolator troubleshooting is provided by the FACP that interfacing with Model XTRI M That panel can even when a Model XTRI M is configured as an but that same Mini Module is wired incorrectly a polarity insensitive mode Infrastructure Building Products Data Sheet 6166 usa siemens com fire XTRI M Interface Module Mini Module Model XTRI M directly to a user supplied switch box the appropriate wires using nuts Tuck the Mini module inside the UL ULC Listed electrical box and dress wiring as required Blank single gang plate Single gang switch box supplied XTRI M Interface Module Operation Programmer Test Unit Model XTRI M Mini Module is programmed with the Siemens field device programmer test unit Model DPU is a compact portable and menu driven accessory for electronically programming and testing Siemens peripheral and devices promptly and reliably For instance the field technician selects the accessory program mode enters the desired address XTRI M programming cable P N 110 694927 utilizes two 2 alligator clip connectors to attach to the XTRI M Model DPU with the programming cable provided with the tester connected Since the Mini Module Model XTRI M is an advanced initiating device the latest Model DPU firmware update is required DPU eliminates the need for cumbersome unreliable mechanical programming methods e g dials and rotary and reduces installation and service costs by electronically programming and testing the module prior to When set in test mode Model DPU will perform a series of diagnostic tests without altering the address or stored data allowing technicians to determine if the module is operating properly field device programmer test unit operates on AC power or rechargeable batteries providing flexibility and in the programming testing of fire safety equipment from practically any location Additionally with the of a Model DPU unit there is no longer a cause for concern with any vibration corrosion and other deteriorating that could negatively affect any electro mechanical addressing mechanism Data Mini Module Model XTRI M has five 5 flying leads that are wired with user supplied wire nuts for connection to addressable circuit with a compatible Siemens FACP using a Siemens compatible FACP Model XTRI M may be used along with Siemens Model intelligent Model addressable manual stations or any other addressable intelligent module e g HZM or Model HCP Additionally the X series modules are compatible with all Desigo and Cerberus Pro and peripherals on the same circuit any and module device on the same loop is possible The only exceptions are the Isolation Module Model HLIM as well as the Siemens Model SBGA 34 audible base Refer to installation manual P N A6V101055487 to ensure Model XTRI M compatibility with the Siemens FACPs for use in the given application Temperature and Humidity Range intelligent interface modules are UL Listed ULC Listed operating conditions for each Mini Module is 32 0 to 120 49 with a relative humidity of no than 95 non condensing Infrastructure Building Products usa siemens com fire Data RANGE 32VDC 95 OR STANDBY MAX WIRE AWG AWG max AWG min for Ordering X Mini Input Device Module built in isolator Device Programmer Unit NOTICE The information contained in this data sheet document is intended only a summary and is subject to change without notice product s described here has have a specific instruction sheet s cover various technical limitation and liability information of install type instruction sheets as well as the General Product and Limitations document which also contains important data provided with the product and are available from the Manufacturer contained in the aforesaid type of documentation should be consulted a fire safety professional before specifying or using the product further questions or assistance concerning problems that might arise relative to the functioning of the equipment please contact Manufacturer Industry Inc Infrastructure Building Products Fernwood Road Florham Park NJ 07932 973 593 2600 October 2020 2