Siemens ZIC-8B Desigo Modular Zone-Indicating Cards (with Model ZIC-2C mounted), Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-zic-8b-desigo-modular-zone-indicating-cards-with-model-zic-2c-mounted-data-sheet-3172408569.pdf |
---|---|
Type | |
Size | 1011.53 KB |
Downloads |
Text Preview
Fire Safety system Cards Model ZIC 8B with Model ZIC 2C mounted Architect Engineer Specifications Operates circuits NACs Three 3 unique signals each circuit Operates 25V or 70VRMS speakers One 1 or 2 two voice operation Eight 8 Class B Y circuits Fully programmable Coded audibles available On board microprocessor Automatic manual control Selectable degrade operation March time Uniform Code 3 Built in strobe synchronization Built in ground fault Circuits power limited NEC 760 Silence non silence option Output power rated 2.0 Amps 24 VDC per circuit UL 864 9th Edition Listed Listed FM NYC Fire Approved Technologies Division Product Overview Zone Indicating Card Model ZIC 8B provides eight 8 fully supervised output circuits for use on each Desigo Fire Safety Modular system control panel FACP ZIC 8B supplies eight 8 B Style Y output circuits power to 2.0 amps maximum per circuit Each circuit can be independently for use with listed audible or visual notification appliances or listed speakers the use of the Model EBA2004 A1 booster amplifier ZIC 8B can also send audio to additional speaker zones ZIC 8B plugs into one 1 slot in the Model CC 5 or Model Card Cage and has on board light emitting diodes LEDs system status and troubleshooting Model ZIC 2C mounts onto Model ZIC 8B and allows each of the Model ZIC 8B circuits to be used for 2 two channel voice applications of power communication operation and conditions are provided as well as indication of circuit or trouble conditions All system status conditions are reported to the system Operating Interface OI circuit or output may be time based as well as automatically with Desigo Modular system logic via ZEUS D programmable custom configuration setting is accomplished from the OI keypad found at front of the Desigo Fire Safety Modular system control may also be time based circuit or output can be manually Armed Disarmed through the keypad of the OI ZIC 8B is UL 864 9th Edition Listed ULC as well as Factory Mutual FM 3010 NYCFD 6160 Approved any circuit or output has been display for the OI will indicate the affected or output and the Disable will illuminate until the circuit or output has returned to the Armed condition Model circuits can also be manually energized or when in the Disarmed state via of the OI Model ZIC 8B Indicating Card Model ZIC 2C Sheet 7343 usa siemens com desigo fire safety Product Overview continued ZIC 8B contains an on board microprocessor which allows notification circuit outputs to function in degrade mode even if the main Desigo Modular processor or the local network communication link has failed degrade mode Model ZIC 8B will respond to an Alarm or Trouble command from any intelligent initiating device or conventional zone initiating device connected in the same local enclosure NAC Zone Each of the eight 8 circuits on ZIC 8B can be configured for use as a standard NAC NAC output can be used as a steady coded horn strobe synchronized horn strobe with silence able horn strobe synchronized or unsynchronized strobe output available coding includes ANSI Temporal March Time 120 pulse per minute PPM Time 60 PPM March Time 30 PPM Canadian Two stage 30 PPM Canadian Two stage PPM and custom coding the horn strobe synchronized setting for the outputs allows Siemens horns strobes and strobes to synchronize all horns in a temporal pattern The horn strobe synchronized for the outputs also allow all strobes to flash simultaneously The silenceable setting will the operator to silence the horns while keeping the strobes active may be programmed through logic to transmit up to three 3 different signal depending on event priority For instance the same circuit can be programmed to the ANSI Temporal pattern for evacuation March Time 120 PPM for tornado and a custom code for recall of the eight 8 circuits on Model ZIC 8B can be configured for use as a standard circuit in single or dual channel systems Dual channel operation requires the Model ZIC 2C module which is mounted to a connector directly on Model ZIC 8B additional mounting space is required for the ZIC 2C Model ZIC 8B can be used with Model ZAM 80 180 bulk amplifier or the Model ZAC 40 amplifier card Model ZIC 8B limited to 25 Watts max zone at 25V when the zone is active 70V Model ZIC 8B is limited to 30 Watts max zone Zone Controls and Indicators SWITCH only Model ZIC 8B LED LED power is applied the Model ZIC 8B card when the card has failed LED when the HNET communication and Model ZIC 8B is in degrade mode LED the detection of a ground fault either negative or positive Model ZIC 8B field wiring LEDs LEDs to indicate that the zone or manually is one 1 LED for each zone the presence of a Trouble either an open circuit or a circuit on the zone is one 1 LED for each zone Technologies Division Ratings Model ZIC 2C per active output CURRENT DRAW Plane CURRENT DRAW Terminal CURRENT DRAW Plane CURRENT DRAW S1 in POWER position S1 in POWER position per active output S1 in POWER position S1 in POWER position Ratings Model ZIC 8B BACK PLANE CURRENT DRAW Power CURRENT DRAW Terminal CURRENT DRAW Plane CURRENT DRAW Note Below Device Current The 24V current is dependent on the usage and wiring of each ZIC circuit Listed in the left hand column the next page are the required current draws for each usage and wiring type Temperature and Humidity Range are UL 864 9th Edition Listed for indoor dry within a temperature range of 120 3 to 32 3 0 2 and a relative humidity 93 2 at a temperature of 90 3 32 2 Current Requirements Per Output Zone for Ordering REQUIREMENT OR Eight Circuit Indicating Card Two Channel Card USAGE USED SYNC UNSYNC 2 CHANNEL ZONE 1 CHANNEL SPEAKER ZONE CODED Standby Current 91mA Technologies Division NOTICE The information contained in this data sheet document is intended only a summary and is subject to change without notice product s described here has have a specific instruction sheet s cover various technical limitation and liability information of install type instruction sheets as well as the General Product and Limitations document which also contains important data provided with the product and are available from the Manufacturer