5499 Power Module 5499 is a 9 amp notification power expander that provides its own AC connection battery charging circuit and backup battery for use with and security controls that have 9 32 VDC outputs such as the Silent Knight Model 5208 Fire Control Communicator The is the cost effective solution for powering notification appliances by the Americans with Disabilities Act ADA The 5499 has ANSI cadence pattern which can upgrade older control panels that cadence capability TO LOCAL FIRE CONTROL 5499 may be connected to a local fire control which utilizes Class A or B type notification circuits operating between 9 and 32 VDC The panel notification circuit is connected to one of the inputs on the The control panel notification circuit end of line resistor is also across two terminals on the 5499 which provides supervision the 5499 and the fire control panel Polarized audible and or notification devices are then connected to the 5499 signal circuits the 4.7kW end of line resistors provided Since the 5499 draws very power from the control it is possible to connect one 5499 to each circuit on the control panel and still provide full supervision of notification circuits all the way back to the control panel UL Listed for 9 amps notification power Built in for from Sensor Gentex and Power supply Four power limited Ground fault detector Lightweight design switch mode reduces heat and power up to more efficiently other systems DIP switches allow for reconfiguration 24 VDC filtered output outputs 2 A or 4 Class B or Class A and 2 Class Additional continuous output 3 amps per output A 2 inputs 2 Class B or 2 Independent trouble AC loss delay option off power to like door holders Stand alone operation to ease of and shipping Operates with most UL Listed devices ANSI Cadence pattern capability BENEFITSfirealarmresources com a complete listing of all approvals and please visit Windows and Windows Logo are trademarks trademarks of Corporation Sensor and are registered of Honeywell Inc document is not to be used for purposes We to keep our product up to and accurate We cover all specific or anticipate requirements All are subject change without notice Technical Support 800 446 6444 Technical Specifications 5499 supervises a variety of functions Low AC power Low battery condition Earth ground fault Auxiliary output power limit condition EOL supervision trouble or power limited at an output a trouble condition occurs Firepower 5499 a trouble condition on the host control circuits to which it is connected Firepower still maintains the ability to be activated by host control In addition the 5499 provides a C trouble relay output as an alternative to the notification circuit trouble 12.25 W x 16 H x 3 D 30.88 cm W x cm H x 7.62 D cm Temperature 32 to 120 0 to 10 93 non condensing Input 120 AC at 3.0A 24VDC at 9A 75mA 205mA Power Circuit 1 Circuits 4 Configuration Class A Class B Class A 2 Class B Silent Knight Clintonville Road CT 06472 more information more about Honeywell Silent Knight and other by visiting www silentknight com Per Output 3.0 9.0 amps total circuit output Alarm Current for voltages drawn from main panel appliance circuits VDC 6.5mA VDC One input circuit 15 mA Both input 30 mA of Inputs 2 Configuration 2 Class B or 2 Class A Voltage Range 9 32VDC charging Capacity 35.0 AH LIGHTS power on Green trouble Yellow fault Yellow trouble Yellow troubles 1 4 Yellow INFORMATION Distributed Power Module Seismic Compliance Kit LISTINGS UL listed CSFM 7300 0559 123 Meets NFPA 72 requirements MEA 429 92 E Vol XII OSHPD CA OSP 0065 10 350396 Rev H 05 18 2018 Honeywell International Inc

Related Files