INTELLIKNIGHT FIRE ALARM CONTROL PANEL 5808 Loop Addressable Alarm Control System convenience of an addressable fire control panel in a cost effective to use package Model 5808 is a 127 point class leading single loop addressable fire alarm control communicator 5808 provides you with the revolutionary value and performance of addressable sensing technology with exclusive built in digital communication distributed intelligent power easy to use interface features such as drift compensation and maintenance alert are delivered in this powerful FACP from Knight more information about the IntelliKnight system or to locate your nearest source please call basic 5808 system can be enhanced by adding such as 5860 remote annunciator 5824 printer interface module for printing system and 5496 intelligent power module 5808 supports or SK protocol devices 5808 also features a powerful dual line fire communicator that allows for reporting all system activity to a remote monitoring location Built in support for up to 99 SK detectors and 99 SK Built in support for 127 SD devices Up to 125 zones and 125 output groups Uses standard wire shielded or twisted pair required Built in digital communicator Central station reporting by point or by zone Supports Class B Style 4 and Class A Style 6 or 7 for SLC Distributed intelligent power Drift compensation 13 pre programmed output cadences including ANSI and 4 programmable outputs Notification circuits can be configured as 2 Class A Z or 4 Class B Style Y or auxiliary power for constant or door holder power Built in annunciator with 80 character LCD display RS 485 bus provides communication to system a PC Built in RS 232 and USB interface for programming Upload or download programming event history or status via remote or direct connection Improvements in SKSS deliver five times faster Built in synchronization for appliances from AMSECO Faraday System Sensor and Wheelock One Form C trouble relay rated at 2.5A at 27.4 VDC and Form C programmable relays rated at 2.5A at 27.4 5808 Plex 2 door option combines a dead front door with a clear window limiting to the panel while providing single operation of the reset and silence Integrated dead front panel protects operator exposure to electrical components The FACP enclosure features a Plexiglass window to protect annunciator Acknowledge function allows operator to keep of event status 5800 can be surface or flush mounted 5808 signal line circuit SLC supports device types of the same protocol SK SD cannot mix SD and SK SLC devices on a FIRE ALARM CONTROL PANEL AC 120 VRMS at 50 60 Hz Accessory Load 6A 27.4 Power 6A 27.4 VDC Current 170 mA Current 365 mA Auxiliary Circuits 27.4 VDC per circuit power Charging Capacity AH Size 18 AH max allowed in Larger capacity batteries can housed in an RBB accessory Mount Dimensions W x 24.75 H x 3.5 D W x 62.9 H x 8.73 D cm Dimensions W x 26.4 H x 4.65 D W x 67 H x 11.8 D cm 28 lbs 12.8 kg Red Requirements Part 15 and Part 68 approved of Jack RJ31X two required 13 NFPA 15 NFPA 16 NFPA NFPA 72 Central Station Signalling Local Protective Systems Auxiliary Premises Unit Water Deluge Service Suitable for automatic waterflow sprinkler supervisory non coded signalling services Listed 7165 0559 0142 429 92 E Vol XIV CA OSP 0065 10 Accessories Remote Fire Annunciator the same 80 character backlit display keypad and firefighter key as the 5808 5860 is gray and is red Intelligent Power Module 6 amp notification power expander that four additional power limited appliance circuit outputs LED IO Module 40 LED outputs 8 normally open contact inputs and one piezo output and 5865 4 LED Annunciator 30 programmable LED 15 red 15 yellow outputs and a piezo The 5865 4 adds a silence and switch to the package Serial Parallel Printer Module one parallel and one RS 232 port for connecting a printer to 5808 to print a real time log of system detector status reports and event Relay Board 10 general purpose Form C Used with 5880 module Accessories Silent Knight Software Suite software for FACP Upload and view panel information event history and status Silent Knight Software Suite facility management software viewing of detector status and history via modem or direct Door front cabinet door with clear to limit access to the FACP Battery Box Accessory Use if backup batteries are large to fit into FACP cabinet 16 W x 10 H x 6 D mm W x 254 mm H x 152 mm D Compliance Kit and SK Devices the specification sheets listed for a complete listing of the SD SK devices SD Devices data sheet SK Devices data sheet JumpStart are Registered of Silent Knight Flexput is a of Silent Knight document is not intended to be used for installation purposes We try to our product information up to date and accurate We cannot cover all applications or anticipate all requirements All specifications are to change without notice For more information contact Silent Knight Clintonville Road Northford CT 06472 1610 Phone 800 328 0103 203 484 7118 For Technical Support Please call 800 446 6444 IN AMERICA Rev L 2013 Honeywell International Inc

Related Files