6808 Fire Alarm Control Panel 6808 is an addressable fi re alarm control panel FACP can be confi gured to achieve an overall point capacity up to 198 points It has one built in signaling line circuit which can support 99 System Sensor SK sensors and SK modules or 127 Hochiki SD devices per loop common communications and annunciation link allows up to 17 to be connected via copper or fi ber optic cable A designated is confi gured as the communicator for all panels in the link for single point communications It also has a built in dual POTs and IP communicator and optional cellular side cars 6808 system can be enhanced by adding modules such as the remote annunciator which also has four programmable function to help automate tasks and reduce time spent at the panel wireless compatibility provides options for wireless detection a Class A mesh network It is ideal for hard to wire locations where new wiring is not allowed or to provide an easy fi re system for new construction projects SWIFT devices can combined with other hard wired 6808 compatible devices 6808 also has Form C trouble relay and two programmable Form relays along with powerful features such as drift compensation pre maintenance alert a built in sensor test to comply with NFPA calibration testing requirements and calibration trouble alert supports a variety of devices including the 5860 and 6855 remote annunciators serial parallel printer interface module for system reports the 5496 NAC expander power module and SK or SD devices E AT U R E S B E NE F I T S Capable of providing Convenient eld upgradeable rmware Integrated dual path and POTs and cellular for reliable to 198 points to smaller needs Connect up to 17 on one site with single access using the Network Card panels can mixed compatible models 125 software zones 125 output for exible options 6860 annunciator with 4 x 40 large display 4 programmable buttons time spent at panel Program for simple or tasks Built in USB interface convenient and programming Programmable date for automatic convenient Saving Time Built in dual phone and digital alarm DACT for signaling services UL Listed CSFM 7165 0559 0502 FDNY COA 6246 FM approved Seismic CA pending INFORMATION Addressable Fire Alarm Panel Red cabinet ANNUNCIATORS 4x40 LCD remote fire 4 lines and up to characters per system four buttons 4x20 LCD remote fire 5860 is gray 5860R is red 4x20 LCD remote fire or 5865 4 LED annunciators display up to 30 LEDs 15 red and yellow The 5865 4 has key switches silence and reset and a system LED LED IO module has 40 LED outputs and eight dry contact inputs which are for custom applications You can up to eight 5880 modules on one panel for maximum flexibility compact size allows mounting inside annunciator or in an accessory Product Information LINE CIRCUIT SLC 6808 SLC loop supports multiple types maintenance alerts and a sensor test to comply with NFPA calibration testing requirements LIGHTS General Alarm Red Flashes if in solid when alarm is silenced Supervisory Yellow Flashes if a condition exists solid supervisory is silenced System Troubles Yellow Flashes a trouble condition exists when trouble is silenced System Silenced Yellow when an alarm trouble or condition has been but not yet cleared System Power Green Flashes AC failure solid when systems are normal INTERFACE 6808 built in 4 x 20 annunciator 80 character LCD display large easy to use tactile can be used for system programming and It has five LEDs for supervisory system trouble silenced and system power operations include silencing and troubles resetting alarms the display of alarm troubles and The system non volatile history buffer stores 1,000 for viewing from the built or remote annunciator System can be initiated with a firefighter key or a 4 to 7 digit operator code 6808 KEYPAD 6808 system offers several options simplify and speed up programming AutoProgramming programming required to a new system The built in keypad the 6860 5860 or 6855 remote give you on site access current system programming You also program the system using Honeywell Fire Software Suite which is Windows based TOOLS Silent Knight Selection Tool the installer or design architect a Windows software system tool to create a detailed of Material BOM and battery Honeywell Fire Software Suite communication and panel detector status event and additional data Requires a computer INFORMATION pair is recommended 6808 also has 13 preset cadence patterns ANSI 3.41 LISTINGS AND APPROVALS 13 NFPA 15 NFPA 16 NFPA NFPA 72 Central station remote Local Protective Signaling Auxiliary Protected Premises Water Deluge releasing service for automatic manual sprinkler supervisory DACT COMPATIBLE DEVICES AND the data sheets listed below for a listing of the SK SD or SWIFT SK Devices Data Sheet SD Devices Data Sheet 350616 350618 SWIFT devices a complete and current listing of devices and accessories go to You cannot mix SK and SD in the same fire alarm system COMPATIBLE ADDRESSABLE Multi criteria smoke detector with thermal fixed temperture Reflected beam smoke detector test feature Reflected beam smoke with test feature Supervised control module Six circuit supervised module Photoelectric duct smoke with extended air speed range Four criteria fire and carbon detector Fixed thermal detector 135 Fixed rate of rise detector Fixed high temperature detector 190 Fault isolator module Mini monitor module Monitor module Dual input monitor 10 input monitor module Photoelectric smoke detector Photoelectric smoke with thermal 135 fixed Photoelectric detector with test capability Addressable single action station Addressable dual action pull Addressable relay module Addressable Six relay control Addressable Dual relay module Addressable zone interface Six zone interface module 6 mounting base 4 Flangeless mounting base Intelligent sounder base Low frequency intelligent base Relay base Isolator base COMPATIBLE ADDRESSABLE Addressable 6 base Addressable 6 short circuit base Addressable 6 relay base Addressable 6 sounder base Addressable input module input Addressable notification Addressable relay module Remote test switch and indicator for the SD505 DUCTR Addressable Duct Smoke Addressable Duct housing with relay base Absolute temperature detector Trip point range from 0 Addressable Line isolator Addressable Mini input module switch input Photoelectric smoke Addressable Single or action pull station Addressable smoke detector DEVICES AV devices are all 2 wire Color red

Related Files