Silent Knight A05-0395 Advance Horns & Strobes

File Preview
File Preview
Click below to download for free

File Data

Name silent-knight-a05-0395-advance-horns-strobes-4786250139.pdf
Type PDF
Size 2.54 MB
Downloads

Text Preview

Selectable Output Strobes and Advance selectable output horns strobes horn strobes are rich with features guaranteed to installation times and maximize pro Electrically compatible with existing SpectrAlert products Automatic selection of 12 or 24 volt operation at 15 and 15 75 Plug in design Field selectable candela settings on wall and ceiling units 15 15 75 75 95 110 115 135 150 177 185 Same mounting plate for wall and ceiling mount units Shorting spring on mounting plate for continuity check before Tamper resistant construction Outdoor wall and ceiling products rated from to 151 Design allows minimal intrusion into the back box Horn rated at 88 dbA at 16 volts Rotary switch for horn tone and three volume selections Outdoor products UL listed to UL 1638 strobe and UL 464 horn requirements Outdoor products NEMA 4X rated Compatible with MDL sync module Listings indoor strobes outdoor strobes horn strobes horns chimes SpectrAlert Advance series to simplify installations with features such as plug in instant feedback messages to ensure correct installation of ceiling strobes and horn strobes to a four inch square four inch octagon or double gang box The two wire mounting plate attaches to a single gang box on the mounting plate attach the horn strobe or horn strobe to the mounting plate inserting the product tabs in the mounting plate grooves The will rotate into position locking the product pins into the plate terminals The device will temporarily hold in place a catch until it is secured with a captured mounting screw Outdoor strobes and horn strobes two wire and four are available for wall or ceiling Outdoor horns are available for only All System Sensor outdoor products are rated between 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or applications Current Draw Data Max Strobe Current Draw mA RMS Range Range Volts Volts Max Horn Current Draw mA RMS Pattern Volts Volts Max Current Draw mA RMS 2 wire Horn Strobe Standard Candela Range 15 cd Volts Volts Input High Medium Low High Medium Low Input High Medium Low High Medium Low Max Current Draw mA RMS 2 wire Horn Strobe High Candela Range 135 cd Input High Medium Low High Medium Low Volts Input High Medium Low High Medium Low Volts not use below 32 rating at Derating K series products used at low temperatures listed candela must be reduced in accordance with this table Output cd Candela Tones and Sound Output Data and Horn Strobe Output dBA 74 Medium 78 78 Sound Pattern dB 7 8 and 9 are not available on 2 wire horn strobe DC Volt Nominal Anechoic DC DC Advance Specifications Advance horns strobes and horn strobes shall mount to a standard 4 4 1 back box 4 inch octagon back box or double gang back Two wire products shall also mount to a single gang 2 4 17 8 inch back box A universal mounting plate shall be used for mounting ceiling and wall circuit outputs shall operate between 17 and 33 volts Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit 95 110 115 135 150 177 185 Combination These options are set by a multiple position switch On four wire products the strobe shall be powered independently of the sounder The horn on models shall operate on a coded or non coded power supply Products Advance outdoor horns strobes and horn strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 Fahrenheit The products shall be listed for use with a System Sensor outdoor weatherproof back box with half inch and three fourths inch conduit Module strobes at 1Hz and horns at temporal three Also while operating the strobes the module shall silence the horns on horn strobe models over a pair of wires The module shall mount to a 411 16 411 16 21 8 inch back box The module shall also control two Style Y class B circuits or one Style Z A circuit The module shall synchronize multiple zones Daisy chaining two or more synchronization modules together will synchronize all the zones they The module shall not operate on a coded power supply Operating Temperature Series Operating Temperature Range Flash Rate Voltage Voltage Range2 terminal wire gauge mount dimensions including lens mount dimensions including lens dimensions back box skirt dimensions BBS 2 BBSW 2 back box skirt dimensions BBSC 2 BBSCW 2 weatherproof back box dimensions SA WBB weatherproof back box dimensions SA WBBC trim ring dimensions TR HS TRW HS trim ring dimensions TRC HS TRCW HS P S PC and SC products will operate at 12 V nominal only for 15 and 15 75 cd to 120 0 to 49 to 151 to 66 to 93 non condensing indoor products 12DC FWR or regulated 24DC FWR1 to 17.5 V 12V nominal or 16 to 33 V 24 nominal to 18 AWG diameter 2.5 high 173 mm diameter 64 mm high 4.7 2.5 142 mm L 119 mm W 64 mm D 4.7 1.3 142 mm L 119 mm W 33 mm D 5.0 2.2 151 mm L 128 mm W 56 mm D diameter 2.25 high 180 mm diameter 57 mm high 5.1 2.0 145 mm L 130 mm W 51 mm D diameter 2.0 high 180 mm diameter 51 mm high 4.812 0.35 146 mm L 122 W mm 9 D mm diameter

Related Files