Silent Knight IDPbeamT spec

File Preview
File Preview
Click below to download for free

File Data

Name silent-knight-idpbeamt-spec-0286934175.pdf
Type PDF
Size 749.40 KB
Downloads

Text Preview

IDP Beam IDP Beam T IDP Beam and IDP Beam T are addressable beam smoke detectors use with Silent Knight IFP series fire alarm control panels FACPs are uniquely suited for protecting open areas with high ceilings where methods of smoke detection are difficult to install and maintain The also includes an integrated sensitivity test feature of the single ended reflective design is much easier than dual projected beam detectors Alignment is quickly accomplished using optical sight and a two digit signal strength meter incorporated into the and IDP Beam T for operation from 22 to 131 30 to 55 the IDP Beam and can be used in applications to provide early warning in where temperature extremes exceed the capability of other of smoke detectors IDP Beam and IDP Beam T consist of a transmitter receiver unit and a When smoke enters the area between the unit and the reflector it a reduction in the signal When the smoke level reaches the threshold an alarm is activated beam smoke detectors have four sensitivity selections along with Acclimate settings When either of the two Acclimate settings are the detector will automatically adjust its sensitivity using advanced algorithms to select the optimum sensitivity for the specific IDP Beam T is equipped with an integral sensitivity test feature that of a test filter attached to a servo motor inside the detector optics the remote test station SSRTS451 System Sensor PN RTS451 motor is activated and moves the filter in the pathway of the light beam tests the detector sensitivity This integral sensitivity test feature the user to quickly and easily meet the annual maintenance and test of NFPA 72 16 to 328 foot protection range Single ended reflective design User friendly alignment procedure Six user selectable sensitivity levels Optional integral NFPA 72 sensitivity test feature Removable plug in terminal blocks Digital display for easy alignment Built in automatic gain control compensates for signal deterioration from build up Optional remote test station Rotary address switches for fast installation Paintable cover Beam Smoke Detectors Vol II IDP Beam and IDP Beam T can be mounted over a junction box or surface mounted using Silent Knight surface mounting kit PN System Sensor PN BEAMSMK reflector is surface mounted For in which the reflector cannot be at the necessary angle the multi kit is required PN SSBEAMMMK Sensor PN BEAMMMK IDP Beam and IDP Beam T are compatible the following FACPs IFP 2000 RPS 2000 Intelligent Fire Panel IFP 1000 Intelligent Fire Panel IFP 100 Intelligent Fire Panel IFP 50 Intelligent Fire Panel Meridian Circle Suite 100 Grove Mn 55369 4927 or 800 328 0103 763 493 6475 350282 Rev D 2008 Honeywell International Inc Range 16 328 5 100 m Angle horizontal vertical optics move of the unit Levels Level 1 Level 2 Level 3 4 Acclimate Level 1 to 50 Acclimate 2 to 50 Condition Trouble 96 or more obscuration blockage in mode improper alignment self compensation limit Aid Optical gunsight integral signal strength 2 digit display Normal green Yellow Red Feature Integral sensitivity test filter IDP Beam T sensitivity filter incremental scale on reflector local test local reset switch remote test and reset switch with SSRTS451 and SSRTS451KEY test station 10 H 25.4 cm x 7.5 W 19.1 cm x 3.3 D 8.4 cm for 16 230 7.9 H 20 cm x 9.1 W 23 cm for Beyond 230 15.7 H 40 cm x 18.1 W 46 cm Weight 3.9 lbs 1.8 kg Temperature 22 131 30 55 10 93 non condensing Voltage 15 32 VDC Current Average 2 mA max During Testing Average 500 mA max Current 8.5 mA max Current 4.5 mA max Mode Current 20 mA Electrical Specifications Voltage 15 32V 450 mA max 34V per reflector Consumption 7.7W 24V 15W 32V per reflector Electrical Specifications Voltage 15 32V 92 mA 32V Consumption 1.6W 24V 3W 32V Information Smoke Detector Smoke Detector with Test Feature Range Accessory Kit Required for in excess of 230 ft 70m Kit Provides ceiling or wall capability with increased angular for either the beam or the When installed with the unit SSBEAMSMK also be used Mount Kit Test Station Used to initiate the sensitivity test function Test Station with Key Lock Kit for Transmitter Receiver Unit electrical requirements in the Kit for Reflector See electrical in the Specifications section For ordering purposes an SS has been added to the System Sensor numbers Example Sensor PN for SSB501 is B501 document is not intended to be used for installation purposes We try to keep our information up to date and accurate We cannot cover all specific applications anticipate all requirements All specifications are subject to change without notice more information contact Silent Knight 7550 Meridian Circle Suite 100 Maple Mn 55369 4927 Phone 800 328 0103 Fax 763 493 6475 in the U S A

Related Files