Silent Knight IDPmonitor2 isheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | silent-knight-idpmonitor2-isheet-9126430785.pdf |
---|---|
Type | |
Size | 695.84 KB |
Downloads |
Text Preview
Mounting directly to 4 square electrical boxes see Figure The box must have a minimum depth of 21 8 mounted electrical boxes SMB500 are available Silent Knight All wiring must conform to applicable local ordinances and regulations This module is in for power limited wiring only Install module wiring in accordance with the job draw and appropriate wiring diagrams Set the address on the module per job drawings Note Monitor module L using terminals 6 and 7 re at the address set on the code switches Monitor H using terminals 8 and 9 will automatically at the next higher address For example if the switches are set to 76 module L will respond at 76 and module H will respond at address 77 caution to avoid duplicate addressing of modules the system Secure module to electrical box supplied by installer shown in Figure 2A 1 Controls and Indicators 2A mounting 865 6 7 8 9 2B 0 E N S 0 N E S D D R E S S AND MAINTENANCE Monitor Module mA LED on Operating Voltage 15 to 32 VDC Current Draw Operating Current 750 LED flashing Resistance Ohms IDC wiring resistance 1,500 Ohms Range to 120 0 to 49 to 93 Non condensing H x 4 W x 11 4 D to a 4 square by deep box Electrical Box Installing information is included as a quick reference instal guide Refer to the control panel installation man for detailed system information If the modules will installed in an existing operational system inform the and local authority that the system will be tem out of service Disconnect power to the control before installing the modules This manual should be left with the owner of this equipment Description Dual Monitor Module is intended for use in intel two wire systems It provides two independent initiating device circuits IDC at two separate addresses It is capable of monitoring nor open contact fire alarm and supervisory devices or normally open or normally closed security devices module has a single panel controlled red LED Requirements ensure proper operation this module shall be con to a compatible Silent Knight system control panel available from Silent Knight 3 Typical 2 wire initiating circuit configuration NFPA Style B INITIATING DEVICE CIRCUITS L H POWER LIMITED TO 230 A 12VDC MAX NEXT K EOL K EOL NUMBER OF UL LISTED CONTACT CLOSURE MAY BE USED DO NOT MIX FIRE INITIATING SUPERVISORY OR SECURITY DEVICES ON THE SAME INITIATING DEVICE CIRCUIT CONTACT CLOSURE DEVICES PER INSTALLATION INSTRUCTIONS PANEL OR DEVICE MODULES TO LISTED COMPATIBLE KNIGHT CONTROL PANELS ONLY WIRING SHOWN IS SUPERVISED AND POWER LIMITED 8 5 LINE CIRCUIT SLC VDC MAX PAIR RECOMMENDED A TERMINALS 6 7 RESPONDS AT ADDRESS ON CODE SWITCHES MONITOR B TERMINALS 8 9 AT NEXT HIGHER ADDRESS Meridian Circle Grove MN 55369 4927 800 328 0103 763 493 6475 2006 Silent Knight