IDP Pduct IDP Pduct R IDP Pduct and IDP Pduct R are addressable photoelectric air duct detectors for use with Silent Knight IFP series fire alarm control FACPs IDP Pduct and IDP Pduct R feature low flow technology that enables smoke detection throughout a broad range of airflow environments difficult to solve HVAC applications occur in low airflow duct where reliable smoke detection is critical These duct detectors detect smoke at air speed velocities of 100 feet per minute or greater continuing the same reliable performance to 4000 feet per minute sampling air currents passing through a duct and giving dependable for shutdown of fans blowers and air conditioning systems IDP Pduct and IDP Pduct R prevent the spread of toxic smoke and fire through the protected area intelligent duct detectors communicate and are continuously through the FACP signaling line circuit SLC loop Detector changes caused by dirt temperature or humidity are reported to FACP allowing compensation algorithms to maintain the detector set An advanced indication at the panel identifies the detector allowing for selected maintenance to be performed as needed IDP Pduct and IDP Pduct R are designed for simplified installation and maintenance The modular construction allows for easy cleaning and field replacement of the UL recognized power and sensor Air velocity rating from 100 to 4000 feet per minute 0.5 to 20.32 meters second Support for Class B or Class A wiring Patented telescopic sampling tube Outside mounting tabs Easy and quick mounting to round or rectangular ducts from 1 foot to 12 0.3 to 3.7 meters Easy to clean Rotary address switches for fast installation UL recognized field replaceable power and sensor boards Transparent cover for convenient visual inspection UL 268A listed 3 year warranty Photoelectric Smoke Detectors Vol IV Features Powered outputs for remote LED remote test remote sounder Configure as relay version or jumper to mimic non relay IDP Pduct Patented cover tamper trouble signal Requires both communication line power and of the following 24 VAC VDC or 120 220 for operation Easy and quick mounting to round or ducts from 1 foot to 12 feet 0.3 to meters IDP Pduct and IDP Pduct R are designed use in air handling systems that have air or 100 to 4000 feet per minute 20.3 m s IDP Pduct and IDP Pduct R are compatible the following FACPs IFP 2000 RPS 2000 Intelligent Fire Panel Features Outputs for remote LED display and remote test Incorporates zener diodes to conserve power for communication to other Requires communication line power only IFP 1000 Intelligent Fre Panel IFP 100 Intelligent Fire Panel IFP 50 Intelligent Fire Panel Meridian Circle Suite 100 Grove Mn 55369 4927 or 800 328 0103 763 493 6475 350284 Rev D 2008 Honeywell International Inc 5.5 14 cm 14.4 37 cm 2.8 7 cm Weight 3.4 lbs 1.5 kg IDP Pduct R 3.9 lbs 1.8 kg Temperature 32 120 0 49 10 93 non condensing Velocity to 4000 ft min 0.5 20.3 m s Current 87 mA 20 30 VDC 182 mA RMS 24 52 mA RMS 120 VAC 30 mA RMS 220 240 VAC Electrical Voltage 15 32 VDC Current 300 24 VDC Electrical Aux Contacts DPDT 10 30 VDC 10 277 VAC power factor 240 VA 249 VAC 0.4 power factor 1 8 120 VAC 1 4 HP 240 VAC Contacts SPST 2.0A 30 VDC resistive Supply Voltage 20 VDC 24 VAC 50 Hz 120 50 Hz 220 240 VAC 50 Hz Current 26 mA 20 VAC 65 mA RMS 24 44 mA RMS 120 VAC 25 mA RMS 220 240 VAC Response Time 3 10 sec Up Time 2 sec Information Smoke Detector Smoke Detector with Relay Sampling Tube Duct Widths 1 2 Sampling Tube Duct Widths 2 4 Sampling Tube Duct Widths 4 8 Sampling Tube Duct Widths 8 12 Photoelectric Sensor Board Power Board for IDP Pduct relay LED Annunciator Power Board for with relay Remote Test Remote Test Filters Test Magnet Magnet with Telescoping Handle Photo Insect Screen End Cap for Plastic Tube End Cap for Metal Sampling Unless otherwise noted specifications apply to IDP Pduct and For ordering purposes an SS has been added to the System part numbers Example Sensor PN for SSB501 is document is not intended to be used for installation purposes We try to keep our information up to date and accurate We cannot cover all specific applications anticipate all requirements All specifications are subject to change without notice more information contact Silent Knight 7550 Meridian Circle Suite 100 Maple Mn 55369 4927 Phone 800 328 0103 Fax 763 493 6475 in the U S A

Related Files