Silent Knight IDPpull spec
File Preview
Click below to download for free
Click below to download for free
File Data
Name | silent-knight-idppull-spec-5938164702.pdf |
---|---|
Type | |
Size | 735.81 KB |
Downloads |
Text Preview
Addressable Single Action and Dual Action Stations Vol IX IDP Pull DA IDP Pull DA IDP Pull DA IDP Pull SA is a single action pull station requiring only one to activate the station The IDP Pull DA is a dual action pull requiring two motions to active the station Both pull stations designed to work with Silent Knight IFP series fire alarm control FACPs Installer can open station without causing an alarm condition Dual color LED is visible through handle of station blinks green to normal operation and remains steady red in an alarm Key operated test and reset lock using lock plate actuator Key matches compatible FACP locks Meets the Americans with Disabilities Act Accessibility Guidelines controls and operating mechanisms guidelines Section Meets ADA requirement for 5 lbs maximum pull force to active Shell door and handle molded from durable LEXAN Reliable analog communications for trouble free operation Braille text on station handle Handle latches in down position and the word Activated appears indicating the station has been pulled Rotary address switches for fast installation UL Listed including UL 38 Standard of Manually Actuated System IDP Pull SA and IDP Pull DA can be surface mounted to an surface back box or semi flush mounted on a standard with a minimum depth of 2.13 cm or double gang 4 10.61 cm square electrical box You can also use the SSBG TR System Sensor PN BG TR trim ring if the is being semi flush mounted IDP Pull SA and IDP Pull DA are with the following FACPs IFP 2000 RPS 2000 Intelligent Fire Panel IFP 1000 Intelligent Fire Panel IFP 100 Intelligent Fire Panel IFP 50 Intelligent Fire Panel 350286 Rev D 2007 Honeywell International Inc Meridian Circle Suite 100 Grove Mn 55369 4927 or 800 328 0103 763 493 6475 5.5 14 cm 4 10.2 cm 5.4 oz 3.7 cm LED Green Normal Red Alarm Material LEXAN polycarbonate resin Single pole single throw SPST normally open N O which closes upon activation of the pull station Voltage 15 VDC Current LED flashing 300 Gauge Up to 12 AWG 3.1 mm2 Temperature 32 120 0 49 10 93 non condensing Information Action Pull Station Action Pull Station trim ring backbox indoor outdoor Unless otherwise noted specifications apply to IDP Pull SA and For ordering purposes an SS has been added to the System Sensor numbers Example Sensor PN for SSB501 is B501 document is not intended to be used for installation purposes We try to keep our information up to date and accurate We cannot cover all specific applications anticipate all requirements All specifications are subject to change without notice more information contact Silent Knight 7550 Meridian Circle Suite 100 Maple Mn 55369 4927 Phone 800 328 0103 Fax 763 493 6475 in the U S A