Silent Knight IDPpullsa isheet

File Preview
File Preview
Click below to download for free

File Data

Name silent-knight-idppullsa-isheet-5963028471.pdf
Type PDF
Size 1.25 MB
Downloads

Text Preview

Wiring 2 3 4 GAUGE Addressable Pull Station U S Patent No Des 428,351 6,380,846 Other Patents Pending K200 19 00 IDP Pull SA Addressable pull station is a non coded single action manual pull station a key lock reset feature It provides Silent Knight intelligent fire alarm control panels with one addressable alarm initiating input The addressable module is housed inside pull station The IDP Pull SA is compatible with all Silent Knight intelligent panels that the Intelligent Device Protocol IDP Refer to the FACP Installation Manual to determine the Intelligent Device Protocol is supported The IDP Pull SA meets the ADAAG controls operating mechanisms guidelines section 4.1.3 13 and the ADA requirement for a 5 maximum pull force to activate the pull station Operating instructions are molded into pull station handle along with Braille text Molded Terminal numbers are also present Operating Voltage 24VDC Operating Current LED Flash 300 Range 32 120 0 49 Humidity Range 10 93 non condensing IDP Pull SA Addressable pull station can be surface mounted to a SB I O surface or semi flush mounted on a standard single gang double gang or 4 10.16 cm electrical box The optional BG TR trim ring can be used if the IDP Pull SA is to semi flush mounted activate the single action pull station simply pull down the handle The word appears after the handle is pulled down This will remain until the pull station is reset pull station includes one Single Pole Single Throw SPST Normally Open N O which closes upon activation of the pull station the Pull Station Insert the key into the lock and rotate 1 4 turn counterclockwise Open the door until the handle returns to normal Close and lock the door Pull Station K200 19 00 I56 2736 002 Closing the door automatically resets the switch to the position Opening door will not activate or deactivate the alarm switch Do not detach the door of the pull station during installation The door of pull station cannot be reattached to the backplate after the backplate has already been onto an electrical box the Silent Knight IDP Pull SA addressable pull station in accordance with these instruc applicable NFPA standards national and local Fire and Electrical codes and the require of the AHJ Authority Having Jurisdiction Regular testing of the devices should be con in accordance with the appropriate NFPA standards Failure to follow these directions result in failure of the device to report an alarm condition Silent Knight is not responsible for that have been improperly installed tested or maintained Compliance ADA compliance if the clear floor space only allows forward approach to an object the forward reach height allowed is 48 inches 121.92 cm If the clear floor space parallel approach by a person in a wheelchair the maximum side reach allowed is inches 137.16 cm for Programming information the IDP Pull SA Address IDP Pull SA Addressable pull station is factory preset with address Set the address the pull station by turning the rotary address switches on the addressable module mounted the pull station Only one device per address is allowed Multiple modules may not set to the same address on the Signaling Line Circuit Once the address is set record it the space provided on the product ID label located inside the pull station 1 3 2 1 1 O R M A L 50997 REV A IDENTIFICATION LABEL Approved Label Here 12 Series ALARM BOX TO DOCUMENT Opening the pull door will not activate or the alarm switch OPERATION RED Smartscan GREEN LED is through handle 1 1 ADDRESS SWITCHES

Related Files