Silent Knight IDPrelay spec

File Preview
File Preview
Click below to download for free

File Data

Name silent-knight-idprelay-spec-8759340261.pdf
Type PDF
Size 750.19 KB
Downloads

Text Preview

Addressable Relay Module Vol V IDP Relay is an addressable relay module for with Silent Knight IFP series fire alarm control FACPs The IDP Relay allows a Silent FACP to switch discrete contacts by code The relay contains two isolated sets of C contacts which operate as a DPDT switch supervision is provided for the notification circuit IDP Relay contacts can be used for virtually any open or normally closed application Each is programmed with a unique signaling circuit SLC loop address When an event that controls the IDP Relay the relay is by the FACP sets of Form C contacts are rated for a variety of amps see controlled status LED that flashes green in state and is solid red in alarm programming is completely flexible be to zone conditions LED visible through the cover plate ivory cover plate address switches for fast installation screws for easy wiring Listed IDP Relay mounts directly into a 4 square box The box must have a minimum depth 2 1 8 A surface mount electrical box SSSMB500 System Sensor PN SMB500 is from Silent Knight IDP Relay is compatible with the following Intelligent Fire Panel Intelligent Fire Panel Intelligent Fire Panel Intelligent Fire Panel Information Relay Module 4 Square Surface Mount Electrical Module Barrier For ordering purposes an SS has been added to the System part numbers example System Sensor PN for SSB501 is Meridian Circl e S uite 100 aple Grove Mn 55369 4928 or 800 328 0103 ax 763 493 6475 350290 Rev D International Inc the IDP Relay Module 4.5 11.4 cm 4 10.2 cm 1.3 3 cm Weight 6.3 oz 196 g Temperature 32 120 0 49 10 93 non condensing Voltage 15 32 VDC Draw 6.5 mA max LED on Current LED flashing direct poll LED flashing group poll Resistance Not used Current max 24 VDC one communication 5 sec with LED enabled Current 5.5 mA with LED latched on Loop Resistance 40 maX Contact Ratings Voltage A A A A A A A A A VDC VDC VDC VAC VDC VDC VAC VAC VAC 5 ms 2 ms 35 35 35 A VAC document is not intended to be used for installation purposes We try to keep our information up to date and accurate We cannot cover all s pecific application anticipate all requirements All specifications are subject to change without notice more information contact Silent Knight 7550 Meridian C ircle Suite 100 Maple MN 55369 4927 Phone 800 328 0103 fax 763 493 6475 in the USA

Related Files