Silent Knight IDPzone spec
File Preview
Click below to download for free
Click below to download for free
File Data
Name | silent-knight-idpzone-spec-4083512769.pdf |
---|---|
Type | |
Size | 714.52 KB |
Downloads |
Text Preview
IDP Zone IDP Zone is an addressable two wire interface for use with Silent Knight IFP series fire control panels FACPs The IDP Zone allows Silent Knight FACP to interface and monitor two conventional smoke detectors This means you retrofit an existing building and use existing devices IDP Zone is addressed through the signaling circuit loop of the FACP It transmits the status of full zone of two wire detectors to the FACP conditions are reported as normal open or The IDP Zone supervises the zone of and the connection of the external power two wire detectors being monitored must be UL with the IDP Zone a conventional two wire loop to an SLC supervised for Style B and Style D wiring controlled status LED that flashes green in state and is solid red in alarm ivory cover plate address switches for fast installation screws for easy wiring Listed IDP Zone mounts directly into a 4 square box The box must have a minimum depth 2 1 8 A surface mount electrical box part SMB500 is available from Silent Knight Meridian Circle Suite 100 aple Grove Mn 55369 4928 or 800 328 0103 763 493 6475 Two Wire Interface Module V IDP Zone is compatible with the following Intelligent Fire Panel Intelligent Fire Panel Intelligent Fire Panel Intelligent Fire Panel Information Two Wire Interface Module 4 Square Surface Mount Electrical For ordering purposes an SS has been added to the Sensor part number Example System Sensor for SSB501 is B501 350292 Rev D International Inc two wire conventional detectors NFPA Style B two wire conventioanl detectors NFPA Style D 4.5 11.4 cm 4 10.2 cm 1.3 3.2 cm Weight 6.3 oz 196 g Temperature 32 120 0 49 10 93 non condensing Operating Voltage 15 32 VDC Current Draw 5.1 mA LED on Current 300 average LED flashing Resistence 3.9K Ohms IDC wiring Resistence 25 Ohms Power Supply 18 28 VDC power limited 28 VDC when used with intrinsically safe applications Voltage 0.1V RMS max 90 mA per module document is not intended to be used for installation purposes We try to keep our information up to date and accurate We cannot cover all s pecific application anticipate all requirements All specifications are subject to change without notice more information contact Silent Knight 7550 Meridian C ircle Suite 100 Maple MN 55369 4927 Phone 800 328 0103 fax 763 493 6475 in the USA