Silent Knight ifp100csfm
File Preview
Click below to download for free
Click below to download for free
File Data
Name | silent-knight-ifp100csfm-4502819736.pdf |
---|---|
Type | |
Size | 617.16 KB |
Downloads |
Text Preview
CALIFORNIA DEPARTMENT OF FORESTRY FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL ENGINEERING BUILDING MATERIALS LISTING PROGRAM SERVICE 1 of 2 Unit High Rise Knight Security 7550 Meridian Circle Maple Grove MN 55369 Michael McIsaac 763 493 6400 FAX 763 391 5464 5808 IFP 100 Fire Alarm Control Units Power limited automatic manual local station central station waterflow water releasing and sprinkler supervisory service to listee s data sheet for additional detailed product description and operational System components IFP 100 SDM 122723E VAC Primary 24 VDC Secondary Units Resistor User Interface User Interface Module Interface Expander Supply Annunciator IO Module Interface Board Notification Module Isolation Module Base Detector Module Annunciator Polarity Module Connect Module accordance with listee s printed installation instructions applicable codes and ordinances and a manner acceptable to the authority having jurisdiction name model number electrical rating and UL label 08 17 2006 jw No No 7170 0559 142 2 of 2 as control units for use in high rise structures when used in conjunction with Model Voice Tone Evacuation Unit CSFM Listing No 6912 0559 122 EVAX Audio System Models EVAX 25 CSFM Listing No 06911 1446 100 EVAX 50 or EVAX CSFM Listing No 06911 1446 102 EVX 2ZA or EVX 4Z Zone Splitters CSFM Listing 06912 1446 101 HMX MP or HMX DP Voice Evacuation System CSFM Listing No two way firefighter telephone and separately listed electrically and compatible initiating and indicating devices Also suitable for non high rise applications where the voice evacuation and two way telephone are not required Refer to listee Installation Instruction Manual for control units can generate a distinctive three pulse Temporal Pattern Fire Alarm Signal for total evacuation in accordance with NFPA 72 2002 Edition control unit meets the requirements of UL 864 8th Edition Standards Fire Alarm Verification Feature delay of fire alarm signal the maximum period shall not exceed 30 seconds listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results other data but does not make an independent verification of any claims This listing is not an endorsement or of the item listed This listing should not be used to verify correct operational requirements or installation Refer to listee data sheet installation instructions and or other suitable information sources 08 17 2006 jw Expires June 30 2009 Issued By 6 2008 HO Chief Engineering Division