Silent Knight IFP2000spec

File Preview
File Preview
Click below to download for free

File Data

Name silent-knight-ifp2000spec-9540876132.pdf
Type PDF
Size 849.25 KB
Downloads

Text Preview

IFP 2000 RPS 2000 IFP 2000 is an intelligent analog addressable fire alarm control FACP The basic IFP 2000 panel contains one built in line circuit SLC which can support 159 IDP sensors and IDP modules Additional SLC loops can be added using the 5815XL SLC expander to increase the overall point capacity a maximum of 636 points per panel has the interconnection capability for up to 8 panels The has two modes of operation Multiple panels covering one building or multiple independent buildings is used in a networked system where at least one IFP is in the system It is the same as an IFP 2000 without the has eight on board Flexput circuits that can be for auxiliary power notification outputs or for smoke detector inputs Class A or Class B The FACP has a built in dual line digital fire communicator Form C relay and two programmable Form C relays IFP 2000 has features such as detector sensitivity day night thresholds compensation pre trouble maintenance alert and calibration alert supports a variety of devices including RA 2000 remote 5824 serial parallel printer interface module for event system reports RPS 1000 intelligent power module and Device Protocol IDP devices Built in support for up to 159 IDP sensors and 159 IDP modules to 636 points per IFP 2000 panel RPS 2000 is used in a networked system where at least one IFP is in the system Up to eight IFP 2000 or RPS 2000 panels can be networked up to 5088 total points Networked panels can be configured to emulate a large virtual or can be segmented into separate sites for multiple applications Built in UL listed digital communicator for remote reporting of activity and system programming 9.0A of output power is available through 8 sets of terminals for and auxiliary applications per panel Supports Class B Style 4 and Class A Style 6 or Style 7 for SLC and SBUSs Flexput I O circuits configurable for auxiliary power notification or conventional smoke detector inputs Notification can be configured as Class A Style Z or Class B Style 2 and 4 wire smoke detectors can be configured as Class A D or Class B Style B Two RS 485 buses provide communication to system Clintonville Road CT 06472 1610 or 800 328 0103 203 484 7118 Analog Addressable Alarm Control System Built in USB interface for programming Dedicated Form C trouble relay and two purpose Form C programmable rated at 2.5 amps at 24 VDC System automatically tests IDP devices 13 preset notification cadence patterns ANSI 3.41 and four user patterns Programmable to automatically display event first or display tally of system Four line LCD display with 40 characters line Built in synchronization for appliances AMSECO Gentex System and Wheelock 999 software zones and 999 output Programmable date setting for Daylight Time JumpStart auto programming allows for set up time by selecting default for many programming tasks The IFP 2000 RPS 2000 can be surface flush mounted Four programmable function keys 350028 Rev B 09 520 2009 Honeywell International Inc Mount Dim 14.75 x 25 x 4 W x 63.5 H x 10.16 D cm Dimensions 16 x 26.4 x 4.65 W x 67 H x 11.8 D cm 28 lbs 12.8 kg Red Temperature 32 120 0 49 10 93 non condensing AC 120 VAC 50 60 Hz 5.0A AC 240 VAC 50 60 Hz 2.5A Accessory Load 9A 24 VDC power limited Current 290 mA Current 530 mA Charging Capacity 17 to 55 AH Size 18 AH max allowed in control panel cabinet capacity batteries can be housed in RBB or AB 55 cabinet Circuits circuits that can be programmed individually as Circuits 3A per circuit 24 VDC power limited Power Circuits 3A per circuit 24 VDC power Circuit 100 mA per circuit 24 VDC power limited Lights Alarm Red On when in alarm Yellow On when a supervisory condition exists Troubles Yellow On when a trouble condition exists Silenced Yellow On when an alarm trouble or condition has been silenced but not yet cleared Power Green Off for AC failure On when power are normal FCC Part 15 Part 68 approved RJ31X two required 13 NFPA 15 NFPA 16 NFPA 70 NFPA 72 Central Remote Signalling Local Protective Signalling Auxiliary Protected Premises Unit Water Deluge Service Suitable for automatic manual waterflow supervisory DACT non coded signalling services Approvals UL Listed FM Approved City of New York CSFM Current Freq VDC 3 A max 0 Hz VDC 3 A max 0 Hz number Releasing Solenoids Information Fire Alarm Control Panel Voltage 240VAC Intelligent Fire Control Panel Fire Alarm Control Panel built in display Voltage 240VAC Intelligent Fire control Panel without built in display Accessories Remote Annunciator Four line LCD with 40 characters per line Remote Annunciator Four line LCD with 40 characters per line Line Circuit SLC Expander amp Intelligent Power Module with 6 amp intelligent Power Module Printer Interface Module I O Module Fire Annunciators Interface Board 5865 4 Devices the specification sheets listed below for a complete listing the IDP devices Device Protocol devices sheet Accessories repeater board for fiber optic repeater board for twisted pair Wired twisted pair network repeater card cabinet kit optic network repeater card and kit Accessories Knight Software Suite 2 Provides upload download and reporting Battery Box Accessory Cabinet for backup batteries up to 35 AH 16 W x 10 H x 6 D W x 25.4 H x 15.24 D cm Battery Box Accessory Cabinet for backup batteries that are AH 55AH 20 W x 12 H x 7.5 D W x 30.48 H x 19.05 D cm document is not intended to be used for installation purposes We try to keep our information up to date and accurate We cannot cover all specific applications or all requirements All specifications are subject to change without notice For information contact Silent Knight 12 Clintonville Road Northford CT 06472 1610 800 328 0103 Fax 203 484 7118 www farenhyt com in the U S A

Related Files