Silent Knight IntelliKnight System Sensor Device Specification Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

INTELLIKNIGHT ACCESSORY Devices SK Protocol Devices with SK Protocol Module devices are intelligent addressable devices for use the following IntelliKnight addressable fire alarm control FACPs 5820XL 5808 and 5700 detectors modules and accessories communicate to the over the signaling line circuit loop SLC loop using a two connection Shielded or twisted wire is not required Up to addressable SK detectors and 99 SK modules can with the FACP on a single SLC loop Any of addressable SK devices and SK modules can be on a single SLC loop assortment of SK detectors modules and accessories that compatible with IntelliKnight addressable FACPs are below For detailed information on SK devices see device specification sheet plug in photoelectric smoke detector offers a unique optical chamber that is engineered to smoke produced by a wide of combustion sources 6 base base Included plug in photoelectric smoke detector with thermal offers a unique optical sensing chamber that is to sense smoke produced by a wide range of sources Dual electronic thermistors add 135 thermal technology to maximize detection Base plug in ionization smoke detector SK ION incorporates a single source dual chamber design to respond quickly to broad range of fires 6 base included fixed temperature thermal detector uses a thermistor sensing circuit produce 135 57 fixed detection Base included variable high temperature that provides high temperature detection at 135 57 88 Base included base included fixed temperature and rate of rise thermal detector that a thermistor sensing circuit to produce 135 thermal protection Rate of rise detection occurs 15 per minute 9 per minute Base included beam smoke detector that is suited for protecting areas with high ceilings other methods of smoke are difficult to install maintain and beam smoke detector that an integrated sensitivity test feature The SK is uniquely suited for protecting open areas with ceilings where other methods of smoke detection difficult to install and maintain Intelligent photoelectric air smoke detector used with included provides detection of smoke in air through HVAC SK housing contains a vacant for SK RELAY sold The SK DUCT requires communication line only both thermal and photoelectric technologies interact to maximize detection The SK ACCLIMATE an on board microprocessor with advanced software focuses on rejecting nuisance alarms Base SK FIRE CO is a plug in device that provides fire and carbon monoxide detection The SK FIRE CO be used in conjunction with B200S intelligent sounder base monitor module that acts as an interface to contact such as waterflow switches and pull stations SK MONITOR supports Class B supervised or Class supervised wiring ACCESSORY compact and light weight monitor module that acts as an to contact devices such as waterflow switches and stations The SK MINIMON supports Class B supervised monitor module with two initiating circuits that acts as an to contact devices such as waterflow switches and stations Because the SK MONITOR 2 is capable of two separate Class B circuits it is ideal for tamper switch and flow switch monitoring 10 point monitor module that acts as an interface to devices such as waterflow switches and pull Conventional 4 wire smoke detectors can be for alarm and trouble conditions The SK supports ten Class B or five Class A contact inputs relay module that allows an FACP to switch discrete by code command The relay contains two isolated of Form C contacts which operate as a DPDT switch relay module that has six Form C relays The SK RELAY 6 an FACP to switch discrete contacts by code and can be used by virtually any normally open or closed application SK RELAYMON 2 combines two relay outputs and two inputs into one module device The module is of Class B supervised wiring to the monitored It also contains Form C relay contacts allowing the to switch the contacts on command notification module that has six modules for maximum allowing you to add circuits wherever they are on an FACP SLC loop The provides supervised of wiring to load devices that require an external supply or amplifier to operate such as bells horns strobes The SK CONTROL 6 supports Class B and A wiring and has a short circuit protection monitor for module to protect external power supplies against short conditions on the NAC notification module that lets you add notification circuits they are needed on an FACP SLC loop The SK provides supervised monitoring of wiring to load such as bells horns and strobes two wire interface module that allows an FACP to interface and monitor two wire conventional smoke detectors means you can retrofit an existing building and use existing devices The SK ZONE supports Style B and Style wiring two wire interface module that has six integrated modules and an FACP to interface with and monitor two wire smoke detectors This means you can retrofit an building and use existing conventional devices The SK supports Class B and Class A wiring line isolator module that acts as an switch that opens when the line on the SLC loop drops below four Isolator modules are spaced between of sensors or modules in a loop to the rest of the loop If a short occurs any two isolators then both immediately switch to an open state and isolate the devices between them SK PULL SA is a single action pull station requiring only motion to activate the station The SK PULL DA is a dual pull station requiring two motions to active the station B210LP B501 is a 4 mounting base B201LP is a 6 mounting Both have built in remote annunciator connections B200SR is designed for new and dwelling unit applications It offers flexibility in installation and operation to meet or UL 268 and UL 464 requirements sounder base in to the communication between the sensor head and the fire alarm control panel FACP to the same address as the detector but as a unique device on the loop The B200S has support for CO detection the SK FIRE CO 6 mounting base with a built in Form C relay contact Lets control a wide variety of normally open and normally closed The B224RB supports Class B and Class A wiring 6 mounting base with a built in isolator for SK series The B224BI prevents an entire communication loop being disabled when a short circuit occurs by isolating any of a loop that has a short from the rest of the loop the entire loop when the cause of the short circuit is Supports Class B and Class A wiring Sounder document is not intended to be used for installation purposes We try to our product information up to date and accurate We cannot cover all applications or anticipate all requirements All specifications are subject change without notice For more information contact Silent Knight 12 Road Northford CT 06472 1610 Phone 800 328 0103 203 484 7118 For Technical Support Please call 800 446 6444 53623 Rev D 2013 Honeywell International Inc

Related Files