Silent Knight PS-SA PS-DA PS-DASP Fire Alarm Pull Stations Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | silent-knight-ps-sa-ps-da-ps-dasp-fire-alarm-pull-stations-data-sheet-2379841650.pdf |
---|---|
Type | |
Size | 1.22 MB |
Downloads |
Text Preview
CONVENTIONAL FIRE CONTROL PANEL ACCESSORY and PS SA Pull stations to Install and Operate PS DA PS SA Pull Stations are non coded manual pull stations which provide a Fire Alarm Control Panel with a single alarm initiating input signal The PS DA PS SA pull stations includes both single action and models equipped with key lock reset It was designed to meet multiple applications with the installer end user in mind Its innovative design durable construction and multiple mounting options make the PS and PS SA simple to install maintain and operate single action pull station is by a single pull down of alarm handle The dual action require pushing in the then pulling the handle for activation The PS manual pull stations are listed and meet the ADA of a 5 lbs maximum force to activate Operating are molded into the along with Braille text terminal numbers can be adjacent to the wiring termi Single action with and a key lock reset wires are provided for con to the Fire Alarm Control FACP initiation circuit Dual action model with terminal connections and a lock reset Same as PS DA except hex lock reset Same as PS DA with use listing Includes SB backbox and sealing gasket Same as PS DA with both English and operating instructions UL Listed CSFM Listed Meets ADA requirements Operating instructions are mold into the handle along with text Made of durable Lexan Available in Spanish Key resettable Easy to Install and operate Single or dual action Surface mount box available Contact 13.97 cm 10.16 cm 3.65 cm to 120 to 49 A 30 VAC VDC Mount Ring FIRE CONTROL PANEL ACCESSORY and PS SA Pull Stations Specification Fire Alarm Stations shall be non code with a key operated reset lock in order that they may be tested so designed that after actual Emergency Operation they cannot be restored to normal except by use of a An operated station shall automatically condition itself so as to be visually detected as activated Manual shall be constructed of red colored LEXAN or polycarbonate equivalent with clearly visible operating provided on the cover The word FIRE shall appear on the front of the stations in white letters 1.00 25.4 mm or larger Stations shall be suitable for surface mounting on matching back box SB 10 or mounting on a standard single gang double gang or 4 10.16 cm square electrical box and shall installed within the limits defined by the Americans with Disabilities Act ADA or per national local require Manual Stations shall be Underwriters Laboratories listed The words on the PS DASP shall appear on the front of the station in white letters 3 4 high Front View Front View Rear View Rear View document is not intended to be used for installation purposes We try to our product information up to date and accurate We cannot cover all applications or anticipate all requirements All specifications are sub to change without notice For more information contact Silent Knight 12 Road Northford CT 06472 1610 Phone 800 328 0103 203 484 7118 www silentknight com IN AMERICA 350241 Rev D 2011 Honeywell International Inc