Silent Knight SK-2 Conventional FACP 2 Zone
File Preview
Click below to download for free
Click below to download for free
File Data
Name | silent-knight-sk-2-conventional-facp-2-zone-1238459067.pdf |
---|---|
Type | |
Size | 651.19 KB |
Downloads |
Text Preview
SK 2 E SK 4 E Fire Alarm Control Panel Instructions Only the GREEN A C POWER LED is on other LED are off KEY The key to open the panel can be found at the location AUDIBLE DEVICES ARE SOUNDING AN ALARM Evacuate the protected area Notify the monitoring service and or the Fire Department immediately Tell them briefly what happened and your current status Fire Department Monitoring Service If the Fire Department is responding be prepared to provide directions to arriving firefighters TROUBLE ONLY Notify the monitoring service and or Fire department if this panel is connected to either one and tell them what is Silence audible devices by unlocking and opening the panel and pressing the ACKNOWLEDGE key for a minimum of one The yellow SYSTEM TROUBLE LED will remain on Contact authorized service personnel immediately See NOT ALLOW TROUBLE CONDITIONS TO REMAIN LOGGED IN THE SYSTEM THE PROTECTION SYSTEM OFFERS HAS BEEN COMPROMISED OR ELIMINATED WHEN A TROUBLE CONDITION return to normal after an alarm Do not enter the protected area until safe to do so Clear all initiating devices Smoke detectors will not reset if there is still smoke in the area Reset the control panel PRESS the RESET key failure or brownout AC power drops too low or fails the AC POWER LED will go out SYSTEM TROUBLE LED will turn on the POWER TROUBLE LED turn on and the panel buzzer and any other audible trouble will sound Contact authorized service personnel See below the event of trouble contact the local Silent Knight Service Representative Number activation Fire Drill or otherwise Appliance Circuits NACs can be activated by a Manual Pull Station You may want to disconnect municipal box by sliding switch located on SK 4XTM module to disconnect position to the right If a DACT is notify the monitoring service before any fire drills or tests Silencing Appliance Circuits may be silenced by pressing the key and then the ALARM SILENCE key The SILENCE LED will turn on Subsequent alarms will circuits Press the RESET key to clear the silenced Notification Appliance Circuits may be programmed as Also Signal Silence Inhibit if enabled will silencing of NACs for one minute after an alarm see test the lamps and piezo sounder and release the RESET key and check all LEDs Every LED be on and the piezo should sound more information refer to the SK 2 E SK 4 E Manual 52604 It is kept in the following location SHEET SHALL BE FRAMED ADJACENT TO CONTROL PANEL 52607 Rev A 08 08 05 ECN 05 276