SIlent Knight SK-Control-6 Six Circuit Notification Module Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

SK CONTROL 6 Circuit Supervised Control Module SK CONTROL 6 is an addressable notification module for use with Silent Knight series fire alarm control panels FACPs The provides supervised monitoring of wiring to load devices require an external power supply or amplifier to operate such as bells and strobes It is capable of supporting Class B and Class A wiring command from the FACP the SK CONTROL 6 will disconnect the and connect the external power supply across the load device disconnection of the supervision provides a positive indication to the that the control relay actually turned on The external power supply is relay isolated from the SLC loop so that a trouble condition on the supply will never interfere with the rest of the system needed you can disable a maximum of three unused modules on the board Each module has terminals for connection to an supply circuit for powering devices on its notification appliance NAC One or more multiple power supplies can be used SK CONTROL 6 has a short circuit protection monitor for each module short circuit protection monitor protects external power supplies short circuit conditions on the NAC In addition an algorithm is to find a short when the module is active The module will all circuits that are not shorted to find the NAC with the problem SK CONTROL 6 mounts directly into the Silent Knight IDP ACB The IDP ACB cabinet has a built in chassis that will accommodate or two SK CONTROL 6 modules Flexible solution for notification where needed Two module mounting Mounting hardware the IDP ACB UL Listed Removable 12 to 18 Unused modules can plug in terminal Support for Class B or A wiring disabled Rotary address for fast Individual LED for module BENEFITSfirealarmresources com Technical Specifications 6.8 17.3 cm 5.8 14.7 cm 1.25 3 cm Weight 6.3 oz 6.5 lbs 38.7 cm 31.8 cm 7.6 cm Voltage 15 32 VDC Power Supply 8mA max in standby 20mA max in alarm Standby Alarm Current 2.25mA max NAC circuit line loss 4VDC Loop Resistance 47KW Temperature 32 120 0 10 93 non condensing INFORMATION Six Input Notification Module SK Module Cabinet Cabinet holds two SK CONTROL 6 is compatible with the Honeywell Silent Knight fire alarm panels Addressable fire alarm control panel Addressable fire alarm control panel an emergency mass notification system Addressable fire alarm control panel Addressable fire alarm control panel Addressable fire alarm control panel Addressable fire alarm control panel Addressable fire alarm control panel Addressable fire alarm control panel an emergency voice system a complete listing of all approvals and please visit Windows and Windows Logo are trademarks trademarks of Corporation Knight System and Honeywell registered of Honeywell Inc document is not to be used for purposes We to keep our product up to and accurate We cover all specific or anticipate requirements All are subject change without notice Technical Support 800 446 6444 more information more about Honeywell Silent Knight and other by visiting www silentknight com Silent Knight Clintonville Road CT 06472 350126 Rev F 11 17 2017 Honeywell International Inc

Related Files