Silent Knight SWIFT Instructional Manual for WSK-RELAY
File Preview
Click below to download for free
Click below to download for free
File Data
Name | silent-knight-swift-instructional-manual-for-wsk-relay-7094256813.pdf |
---|---|
Type | |
Size | 1.00 MB |
Downloads |
Text Preview
I Clintonville Road Northford CT 06472 1610 203 484 7161 Fax 203 484 7118 AND MAINTENANCE INSTRUCTIONS Relay Module Operating Voltage Current Draw Operating Current Transmit RF Power Frequency Range Range Type Life Replacement CONTACT RATINGS VDC mA LED on MHz to 120 0 to 49 to 93 Non condensing Panasonic CR123A or 4 Duracell DL123A year minimum TROUBLE BATTERY LOW display and or during annual maintenance H x 4 W x 1 D Electrical Box preferred mounting option RATING VOLTAGE DESCRIPTION A A A A A A A A VAC VDC VDC VDC VAC VDC VAC VAC 20ms 0.35 0.35 0.75 0.35 1 CONTROLS AND INDICATORS INSTALLING information is included as a quick reference installation guide Refer to control panel installation manual and the SWIFT Wireless Manual for de system information If the modules will be installed in an existing op system inform the operator and local authority that the system will temporarily out of service Disconnect power to the control panel before the modules This manual should be left with the owner user of this equipment DESCRIPTION WSK RELAY Relay Module is intended for use with a wireless gateway or fire alarm control panel FACP It allows a compatible control panel switch discrete contacts by code command The relay contains one isolated of Form C contacts which operate as a SPDT switch and are rated in ac with the table in this manual A single relay module may be used to only one output device Two relay modules must be used in parallel to multiple devices such as a NAC expander Circuit connections to the are not supervised by the module The device communicates through a bi directional mesh network to the gateway and or FACP Rotary dial are provided for setting the module address The module has a controlled LED indicator Figure 1 faceplate includes a magnet for activation and tamper resistance Figure The faceplate magnet activates communication to the panel therefore the must be installed for the module to work properly The magnet also a supervisory tamper fault at the panel if the nameplate is removed NOT remove this magnet The faceplate for a wireless module CANNOT be with the faceplate of a standard wired module 2 FACEPLATE INTERIOR LOCATION NOT REMOVE REQUIREMENTS ensure proper operation this module shall be connected to a compatible Knight system control panel list available from Silent Knight REPLACEMENT battery levels on the wireless devices are displayed as a trouble on an Therefore when the message BATTERY LOW is dis replace the battery in the device This message is an indication that one week of battery life remains relay switch contacts are shipped in the standby state open state but may transferred to the activated closed state during shipping To ensure that switch contacts are in their correct state modules must be made to com with the panel before connecting circuits controlled by the module interfacing with an emergency control function that function must re in 1 second or less replace the batteries in a wireless device use the following steps 4 MODULE MOUNTING Have 4 CR123A or DL123A batteries available Remove the faceplate from the module Open the battery compartment refer to Figure 3 Remove the used batteries and replace with new batteries The battery com is designed such that the batteries can only align in the appropri direction Do not force the batteries into the openings Replace the battery compartment cover Replace the faceplate 3 BATTERY COMPARTMENT technologies can exhibit communication disruption if devices are too close together To avoid this form of disruption SWIFT devices not be placed closer than 2 feet 60 cm apart without an intervening WSK RELAY mounts directly to an SMB500 electrical box see Figure 4 avoid interference with the wireless network metal electrical boxes are NOT Non metal surface mounted electrical boxes SMB500 are from Silent Knight If not using an SMB500 the minimum mounting dimensions for the WSK RELAY are 4in X 3 x 1 deep Do not attach the module to temporary structures such that the place could be altered All wiring must conform to applicable local codes ordinances and For applications interfacing with Emergency Control Functions wiring shall be limited to 3 or 20 in non metallic conduit Install module wiring in accordance with the job drawings and appropri wiring diagrams the address on the module per job drawings Secure module to electrical box supplied by installer as shown in 4 5 TYPICAL MONITORING CONFIGURATION DOES NOT SUPERVISE CIRCUITS NOT USED NORMALLY OPEN COMMON NORMALLY CLOSED ANY WIRING TO TERMINALS 1 4 IS LIMITED A NONPOWER LABEL MUST BE PLACED THE POWER LIMITED TERMINAL ON THE NAMEPLATE INSTALL CONTACT CLOSURE PER MANUFACTURER INSTRUCTIONS IN APPLICATIONS INTERFACING WITH EMERGENCY CONTROL FUNCTIONS WIRING SHALL BE LIMITED TO 3 FEET OR 20 FEET IN NON METALLIC CONDUIT of these products in combination with non Honeywell products in a wireless mesh or to access monitor or control devices in a wireless mesh nework via the inter or another external wide area network may require a separate license from Sipco LLC more information contact Sipco LLC or Ipco LLC at 8215 Roswell Rd Building 900 950 Atlanta GA 303350 or at www sipocollc com or www intusiq com device complies with part 15 of the FCC Rules Operation is subject to the following two conditions This device may not cause harmful interference and This device must accept any interference received including interference that may cause undesired operation Do not make changes to the equipment Changes or modifications not expressly approved by the manufacturer could void the user authority to operate the equipment Knight and Honeywell are registered trademarks of Honeywell International Inc Honeywell 03 02 STATEMENT STATEMENT