Simplex 2080-9056, -9057, -9067, -9068, -9059, -9060, & -9061 Releasing System Peripherals, Abort and Maintenance Switches (B) (C) (D)

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed NYC Acceptance System Peripherals Fire Suppression System Abort Switches and Releasing Circuit RAC Maintenance Switches switches provide a manual Fire Suppression release abort request Pushbutton momentary switch is mounted on a steel single gang plate A protruding collar protects the switch from contact collar is removable if required Available flush or surface mount Flush mounting requires standard single gang box Surface mounting includes a red mounting box Models are available with internal 1.2 k resistor for limited operation switches provide a secure and visible means for servicing Fire Suppression Releasing Appliance Circuits RACs Maintained position keyswitch is mounted on a steel double gang plate Key is removable in either normal or disabled Disabled position opens connection to output circuit places a 16.2 k resistor across the input circuit initiate a supervisory condition at the host panel Disconnect indicator lamp is a bright incandescent with red lens powered from separate 24 VDC Available for flush or surface mount Flush mounting requires a standard double gang box Surface mount models includes a red mounting box listed to Standard 864 systems typically require maintenance disconnect and often require abort switches These abort and switches are clearly labeled and combine easy with rugged construction for high integrity Refer to page 2 for specific product listings NOTE MEA is not applicable to Switches FM is not applicable to Abort Switches As indicated on page 2 these products have been approved by the California State Fire CSFM pursuant to Section 13144.1 of the California Health and Safety Code See Listing 7300 0026 313 for allowable values and or conditions concerning material in this document Abort switches are accepted for use City of New York of Buildings MEA35 93E Maintenance switches were not approved by FM as document revision date Additional listings may be applicable contact your local Simplex supplier for the latest status Listings and approvals under Simplex Time Recorder are the property of Tyco Safety Products Westminster SUPPRESSION ABORT AND HOLD Switch 1 2 size SUPPRESSION DISABLE Switch with Disconnect Indicator Lamp 1 2 size 11 2006 Product Selection see page 3 for specifications Switches Flush mount Surface mount includes mounting box Status ULC CSFM MEA NYC size includes 3 position contact block housing one contact block installed Switches for 4004R Series Suppression Release Panel Current Limited Operation Flush mount Surface mount includes mounting box Status ULC CSFM MEA NYC size includes 1.2 k 1W resistor for current operation and 3 position contact block housing with contact block installed Switches with Disconnect Indicator Lamp Status ULC CSFM size includes 3 position contact block housing 2 contact blocks installed disabled position opens to output and places a 16.2 k resistor across the circuit resistor is removable if required for retrofit Flush mount Surface mount includes mounting box for Field Installation Additional Contact Block for Abort or Maintenance Switch 1 Form C contact UL recognized component for use these switches listings and approvals are not applicable Abort Switch Installation Reference width 76 mm box is supplied with surface mount Switch 2080 9057 or 2080 9068 56 mm into box SUPPRESSION ABORT mm Switch 4 1 2 mm AND HOLD recess 5 32 mm height mm Switch 2 3 4 70 mm mm gasket attaches to box installed for flush mount for surface mount For flush mounting use a 2 3 4 deep 70 mm single gang box 11 2006 Maintenance Switch Installation Reference dimensions 122 mm square box is supplied with surface mount Switch 2080 9060 56 mm into box mm SUPPRESSION DISABLE Switch 4 9 16 116 mm mm gasket attaches to box installed for flush mount for surface mount For flush mounting use a 2 3 4 deep 70 mm double gang box Specifications Ratings Switch One Contact block Silver contacts 1 N O 1 N C rated 2 A resistive 30 VDC Switch with Lamp Contact blocks control Silver contacts 1 N O 1 N C rated 2 A resistive 30 VDC control Silver contacts 1 Form C rated 2 A resistive 30 VDC Switch Indicator models 2080 9059 and Connections Switch Switch with Current Limited Switch Ratings Range Range 2 W incandescent bulb 24 to 30 VDC typical 83 mA 24 VDC requires 24 VDC blocks for in out wiring 18 to 14 AWG wire 0.82 mm2 to 2.08 mm2 blocks for first wire connection 18 to 14 AWG wire 0.82 mm2 to 2.08 mm2 AWG wire lead for second wire connection AWG 0.82 mm2 color coded wire leads for suppression circuit terminal blocks for wiring 18 to 14 AWG wire 0.82 mm2 to 2.08 mm2 F to 120 F 0 C to 49 C to 93 at 90 32 C 11 2006 Simplex and the Simplex logo are trademarks of Tyco International Services AG or its affiliates in the U S and or other countries 2006 Tyco Safety Products Westminster All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Safety Products Westminster Westminster MA 01441 0001 USA 11 2006

Related Files