Simplex 2081-9046 Coil Supervision Module Wiring Instructions

File Preview
File Preview
Click below to download for free

Text Preview

Cautions and Warnings of 2081 9046 Coil Module Coil Module Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of the for shipping damage If damage is apparent immediately file a claim the carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives HAZARD Static electricity can damage components Therefore as follows Ground yourself before opening or installing components use the 553 484 Control Kit Keep uninstalled component wrapped in anti static material at all times publication shows how to connect the 2081 9046 Coil Supervision Module a Fire Alarm Control Panel FACP Refer to the 4010 Fire Alarm Front Installing Operating and Programming Instructions 574 052 for information Refer to the 842 058 Field Wiring Diagram for 4010 wiring information For other FACPs see Field Wiring 841 669 for the 4002 841 984 for the 4002 non power limited for the 4020 and 841 941 for the 4100 2081 9046 Coil Supervision Module shown in Figure 1 supervises and power for an electrically compatible suppression release solenoid coil connected to a 24 VDC Notification Appliance Circuit NAC The input from the NAC must be connected between the Red and Black wires of module The output control voltage to the solenoid is taken from the Yellow Black wires of the module The output control voltage to the suppression is activated when the NAC is activated alarm state i e 24 VDC to Red wire and 0 VDC to the Black wire The output control voltage to the solenoid is non active when the NAC is non active in a supervisory i e negative to the Red wire and positive to the Black wire The module for supervision of the connection to the solenoid coil Diode suppression also provided for overvoltage inductive spikes 1 Coil Supervision Module 2000 Simplex Time Recorder Co Westminster MA 01441 0001 USA Specifications and information shown were current as of publication and are subject to change without notice B Coil Supervision Module Specifications lists below show the input power requirements and the output specifications the 2081 9046 Coil Supervision Module Power Requirements Nominal Voltage Specifications Nominal Voltage Maximum Current Stand By Current VDC VDC A 24 VDC mA Maximum REVERSE NAC ALARM SUPERVISION NAC ALARM SUPERVISION NAC Yellow and Black wires connected to the solenoid are limited indicated by shaded area in Figure 2 must maintain 1 4 separation between the Yellow Black wires and the two input Black and Red power wires SUPERVISED FOR AND GROUND FAULTS 1 1 SUPERVISION MODULE LOCATED IN CONNECTION BOX PER CIRCUIT 1 Separate conduit entrances are required for power limited Red and Black non power limited Yellow and Black wire pairs 2 Power limited cabling must be either FPL FPLR FPLP or equivalent type cable the NEC 2 Wiring Connections for Coil Supervision Module B

Related Files