Simplex 2081 Series System Batteries Sealed Lead-Acid, 110 Ah; (B) (D)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-2081-series-system-batteries-sealed-lead-acid-110-ah-b-d-4681057329.pdf |
---|---|
Type | |
Size | 716.37 KB |
Downloads |
Text Preview
CSFM Listed Battery Cabinet Accessories Batteries and Battery Cabinets 110 Ah Sealed Lead Acid and Compatible Battery Cabinet without charger Batteries have UL 924 recognized pressure relief Batteries 2 required for 24 VDC system appearance may vary 12 V 110 Ah rechargeable sealed battery features Output terminals are high current posts connecting is included with battery cabinet UL ULC and FM fire alarm system requirements are when these batteries are used with a charger and compatible battery cabinet Battery Cabinet ordered separately Use when fire alarm control panel internal charger is of charging 110 Ah batteries not applicable ULC listed 4100ES 4100U systems For compatible Simplex 4100ES 4100U systems requires two wires to a 4100 5128 Battery Terminal Block located in the cabinet For compatible 4100 Legacy systems wiring requires wires for charging and two wires for battery Refer to data sheet S4081 0002 for 4100ES 4100U battery cabinet with charger 110 Ah rechargeable sealed lead acid batteries reliable and repeatable discharge and recharge for use in fire alarm and other systems For use with Simplex fire alarm control panels battery chargers capable of up to 110 Ah mount these in external battery cabinet 2081 9280 located to the control panel Details Connections Connect two of these 12 V batteries series to produce 24 V system voltage Battery sets must of identical voltage model number appearance and the same date of manufacture for proper Battery chemicals and materials can be recycled to information shipped with the battery or on its case to the battery manufacturer or to a similarly qualified processing facility for proper disposal Battery cabinet 2081 9280 has been approved by the California State Fire Marshal pursuant to Section 13144.1 of the California Health and Safety Code See CSFM 7315 0026 144 for allowable values and or conditions concerning material in this document It is subject to re examination revision and possible 2081 9280 was not ULC listed or approved by FM or MEA NYC as of revision date Additional listings may be applicable contact your local Simplex supplier for the latest status Listings and approvals under Simplex Time Recorder are the property of Tyco Safety Products Westminster Battery Cabinet Details Continued Battery capacity testing is recommended to be by using a sealed lead acid battery tester to withdraw a minimum of battery charge Testing available through your local Simplex product supplier Information Refer to Installation Instructions for Battery Cabinet installation details See 4100ES panel data sheet S4100 0031 for additional power charger information Simplex Battery Chargers Reference System Power Supplies SPS 4100 9xxx Series Additional SPS Remote Power Supply RPS TrueAlert Addressable Power TPS Legacy power supplies 4100 5127 Specifications Battery Cabinet Battery Reference Information W x 12 H x 12 D mm x 305 mm x 305 mm battery W x 9 H x 10 1 2 D mm x 230 mm x 267 mm and cables for compatibility with batteries 110 Ah 20 hour discharge rate mounted fuseholder with 80 A included V per battery 2 required for 24 V system Terminals 14 AWG to 2 AWG 2 mm2 to 32 mm2 High current terminal posts Red 82 lbs 37 kg per battery 4100ES 4100U Wiring and 2081 9280 Battery Cabinet Detail Reference Wiring Distance Chart Size mm2 A A A A A A A Distance per Battery Discharge Current Range ft 8 m ft 12.5 m ft 9.5 m ft 20 m ft 15 m ft 10 ft 32 m ft 24 m ft 15.8 m ft 11.9 m ft 51 m ft 38 m ft 25 m ft 19 m ft 13.7 m ft 81.7 m ft 61 m ft 40 m ft 30.5 m ft 22 m ft 17 m ft 130 m ft 97.5 m ft 64 m ft 48.7 m ft 35 m ft 27 m ft 24 m Battery Cabinet Additional Wiring Information battery cabinet output fuse is 80 A for battery protection battery fuse requirement To protect the output conductors install a line fuse rated properly to the load current in the plus side of each output pair Wire per applicable local code Battery output connects to multiple conductor terminal block for connections to other panels requiring external battery power is a registered trademark of Tyco International Services GmbH and is used under license Simplex and the Simplex logo are trademarks of Tyco International Ltd and its and are used under license Safety Products Westminster Westminster MA 01441 0001 USA 2011 Tyco Safety Products Westminster All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice wiring to panel connects to 4100 5128 Battery Distribution Terminal Module in panel cabinet ordered separately To other panels configured for external batteries optional External in line fusing for conductor protection by others refer to information in Wiring Distance ChartControl panel with compatible charger 4100ES shown 12 284 mm 26 1 2 673 mm 12 284 mm Locking top is hinged at back and held open with built in supportSide panel is removable for access to battery connections and charger assemblyfirealarmresources com