Simplex 2081-Series System Batteries, Sealed Lead-Acid; with Applications Reference for Battery Cabinets and Battery Cabinets with Charger (A) (B) (C) (D)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-2081-series-system-batteries-sealed-lead-acid-with-applications-reference-for-battery-cabinets-and-battery-cabinets-with-charger-a-b-c-d-2041758936.pdf |
---|---|
Type | |
Size | 621.11 KB |
Downloads |
Text Preview
Alarm Control Panel Accessories Batteries Sealed Lead Acid with Applications for Battery Cabinets and Battery Cabinets with Charger sealed lead acid batteries Lead calcium grid structure with immobilized in absorbent separator Low maintenance with no need to add water Low self discharge characteristics One piece high impact polystyrene cell cover with high dual seal construction UL 924 recognized pressure relief valves in a variety of capacities Batteries for internal mounting range from 6.2 Ah up to Ah depending on control panel cabinet size Larger batteries up to 110 Ah mount in external battery with models available with internal chargers cabinets with chargers Battery cabinets with charger communicate with their fire alarm control panel and are available for Series and 4010 Series panels rechargeable sealed lead acid batteries provide and repeatable discharge and recharge for use in fire alarm and other systems They are designed with immobilized in an absorbent separator allowing them to rated capacity on the first cycle of their sealed construction packaging is allowed the system electronics enclosure see illustration page 2 When this is applicable the quantity of cabinets and the battery wiring distances are both Where required external battery cabinets can close nippled to the control panel to house larger with battery chargers available in some battery sizes Details Charging These batteries are intended to be used with Simplex battery chargers Connections These batteries are required to be in series to produce 24 V system voltage sets must be of identical voltage model number and approximately the same date of for proper operation Battery capacity testing is recommended to be by using a sealed lead acid battery tester to withdraw a minimum of battery charge The tester applies a variety of amplitude and controlled test pulses that compares terminal against those predicted for the specific battery Testing is available through your local Simplex supplier Sealed Lead Acid Batteries can be Inside Fire Alarm Control Panel Cabinets Battery Cabinets are Available for Battery Requirements Details Continued Shipping Sealed lead acid batteries are shipped via or sea transportation only They are not shipped air Battery chemicals and materials can be Refer to information shipped with the battery or its case Return to the battery manufacturer or to a qualified battery processing facility for proper Refer to details on page 4 and to the referenced individual product data for agency listing status of battery cabinets and chargers The batteries in this document meet the requirements of UL ULC and Factory for use with respective equipment battery chargers as listed on page 3 your local Simplex product supplier for proper battery selection per requirements Listings and approvals under Simplex Time Recorder are the property of Tyco Fire Protection Products 1 2012 Battery Construction Reference appearance will vary with battery size connect or post type terminal varies with battery size cover separator used immobilize electrolyte grids group outer cover hole material black for red for positive is also clearly with and relief valve separator case high impact Battery Size Specifications Model 20 Hour Rate case for service case for new Ah Ah Ah Ah Ah Ah Ah Ah Ah 156 mm 153 mm 153 mm 184 mm 168 mm 67 mm 103 mm 102 mm 86 mm 127 mm with 102 mm 102 mm 102 mm 168 mm 178 mm lbs 2.6 kg lbs 4.2 kg lbs 4.1 kg lbs 6.5 kg lbs 8.8 kg 318 mm 86 mm 179 mm lbs 12.1 kg 197 mm 133 mm 171 mm lbs 12 kg 229 mm 284 mm 140 mm 267 mm 225 mm 230 mm lbs 19 kg Lbs 37 kg Dimensions and weight are per battery and are for reference only Exact size may vary Refer to the tables on page 3 for compatibility These batteries are 12 V each and series connected for 24 V system use When wired in series for 24 V output these batteries are to be of identical voltage appearance model number and the same date of manufacture General Battery Specifications Voltage Rating Rating Charge Discharge Cycles Charge Temperature Range Volts per battery Hour Rate to 150 F to 90 F 15.6 to 32.2 C 1 2012 Battery Compatibility for Fire Alarm Control Panel Mounting Refer to individual fire alarm control panel product data sheets for additional battery application information Control Panel Model Series see legend and notes below 4004R 4005 4006 models 4120 4 or 6 Unit 4 or 6 Unit Model Ah Ah 12.7 Ah Ah Ah Ah Ah 3 3 Ext 3 Ext 3 Ext 2 3 3 4 Ah Ah Requires external battery cabinet compatible with 4100ES 4010ES 4100 and 4120 Series only 3 NA or 3 bay 6 3 Can be placed in the respective equipment cabinet External battery cabinet is required refer to selection chart on page 4 Not applicable not compatible These batteries meet the requirements of UL ULC and Factory Mutual for use with respective equipment battery chargers above Contact your local Simplex product supplier for proper battery selection per system requirements 4010 Cabinets will accommodate 2081 9275 18 Ah batteries but will not allow bottom entry conduit Use 4081 series companion cabinet and charger refer to page 4 4020 Cabinets will accommodate 2081 9271 33 Ah batteries but will not allow bottom entry conduit Some control panel models are listed for battery replacement reference only For 2 bay international applications only 50 Ah batteries will fit in the cabinet External Battery Cabinet Compatibility Reference Cabinets without Chargers connects to charger in panel Compatibility Ah Ah 33 Ah 33 Ah Ah Ah 4010ES and 4100 Cabinets with Chargers Ah and 4010 Compatibility Batteries smaller than those listed are normally mounted in the product cabinet 25 Ah capacity was effective as of 7 2005 4010ES 4100U Can be placed in the respective equipment cabinet Not applicable not compatible Ah 33 Ah 33 Ah Ah Ah 1 2012