ULC CSFM Listed Voltage Monitor Relay provides monitoring of operating voltage For use with 4 wire detectors and similar fire system products Model 2098 9735 operates at 24 VDC Model 2098 9736 operates at 120 VAC ULC listed Relay contact provides continuity to end of line while energized loss of power opens path causing a trouble condition at the panel UL listed to Standard 864 steel cover plate allows convenient for easy location Mounts in single gang box 2 51 mm deep Easy to locate for convenient access end of line relays provide zone voltage mounted on a single gang plate for easy Upon loss of voltage the relay contact opens continuity to the end of line zone wiring resistor to data sheet S4081 0003 for 4081 Series Resistor Harnesses to data sheet S4098 0015 for reference to model encapsulated 24 VDC end of line relay NOTE ULC listing is applicable to model 2098 9735 24 VDC only This product has approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 the California Health and Safety Code See CSFM Listing 7300 0026 013 for values and or conditions concerning material presented in this document It is to re examination revision and possible cancellation This product was not FM MEA NYC approved as of document revision date Additional listings may be contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Safety Products Accessories 2098 Series End of Line Voltage Monitor Relays Mounted 24 VDC or 120 VAC ALARM Relay Cover Plate Specifications Rating Box A resistive 24 VDC 120VAC Gang 2 51 mm minimum coded wire leads 18 AWG mm2 24 VDC Nominal Operation Voltage Voltage to 31 VDC 5 VDC must dropout at VDC mA maximum 31 VDC Current 120 VAC Nominal Operation Voltage to 132 VAC 30 VAC must dropout at VAC mA maximum 132 VAC Voltage Current 1 2008 Wiring Reference Fire Alarm Panel 4 Wire VDC 4 Wire Zone 24 VDC Devices to specific devices for exact wiring contact is energized 4 Wire Zone 120 VAC Devices to specific devices for exact wiring 4 Wire contact is energized Fire Alarm Panel VAC per Circuit per Circuit is a registered trademark of Tyco International Services GMBH and is used under license Simplex and the Simplex logo are trademarks of Tyco International Ltd and its and are used under license 2008 Tyco Safety Products Westminster All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Safety Products Westminster Westminster MA 01441 0001 USA 1 2008