Simplex 2099 Series Manual Stations
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-2099-series-manual-stations-8512740369.pdf |
---|---|
Type | |
Size | 629.65 KB |
Downloads |
Text Preview
Multi Application Peripherals and Accessories Manual Stations Series Single and Double Action Operation and annunciator contact options Action Station Listed Single action models Breakglass type double action models option Key operated only lever protrudes when alarmed resistant reset key lock keyed same as fire alarm cabinet or semi flush mounting mounting option stage alarm French or Bilingual Action Stations require a firm downward pull to the alarm switch Completing the action breaks an plastic break rod visible below the pull lever pull lever latches into the alarm position and remains out of the cover to provide a visible indication of station was alarmed Action Stations Breakglass require the operator strike the front mounted hammer to break the glass and the recessed pull lever The pull lever then operates a single action station action stations can be fitted with an institutional kit Institutional Stations are designed to activate key operation only This allows access for manual to be limited to authorized personnel Operation key insertion and opening of the station cover option activates when the lever is pulled alarm initiation requires a key to activate a located behind the pull lever Reset requires use of a key to reset the pull station and deactivate the alarm switch If the break rod is it must be replaced requires physical activation of the pull lever for institutional stations DOWN GLASS Action Breakglass Action Station Institutional Cover 2000 Simplex International Time Equipment Co Ltd 9 00 to the National Building Code a manual pull shall be installed in every floor area near every exit CAN ULC S524 M91 states that stations mounted not less than 1200 mm nor more than 1400 mm the floor level In addition the National Fire Assocation NFPA Bulletin number 72 reference 5 9 gives specific minimum requirements on this When manual station coverage appears limited in any additional units should be installed Stations should be with the bottom of the station not less than 1.07 m ft or more than 1.52 m 5 ft from the floor Usually are mounted at the 1.37 m 4.5 ft level In order to buildings and facilities accessible to and usable by the handicapped some specifications may require that station be installed not more than 1.07 m 3.5 ft from the Manual Station Specification Chart should be located in the normal path of exit and in the protected area so that they are unobstructed readily accessible should be provided on each floor to obtain a travel not more than 61 m 200 ft to the nearest station any point in the building One station should be for each floor where the maximum floor area is m2 10,000 ft 2 or more Covers and pull levers are constructed of chip and dirt resistant high impact Lexan polycarbonate are red with white lettering and pull levers are white red lettering 2099 9819 Black and 2099 9820 Beige are adapter kits designed to flush mount any one of 2099 series stations Action Models Annun Key Gang Box Depth inches Action Models Annun Key Gang Box Depth inches 1.5 2.0 2.0 2.0 3.0 2.0 2.0 3.0 2.0 1.5 2.0 2.0 2.0 3.0 2.0 2.0 3.0 2.0 Normally Open Contact N C Normally Closed Contact C L Current Limited when activated SHOWN ARE ENGLISH LANGUAGE ADD FOR FRENCH FOR BILINGUAL 2099 9754C 2099 9754CF 2099 9754CB breakglass standard English break rod adapter kit black refer to page 4 adapter kit beige refer to page 4 retaining clip for breakglass cover kit surface mount box sheet metal 5 3 16 H x 4 W x 2 3 16 D 127 mm x 102 mm x 56 mm cast aluminum surface mount box 5 H x 3 7 8 W x 2 3 16 D 127 mm x 98 mm x 56 mm surface mount box sheet metal 5 3 16 H x 4 W x 2 11 16 D 127 mm x 102 mm x 68 mm 9 00 Page 2 Breakglass to installation instructions PER 21 502CAN for additional information Information MOUNTING for 3 4 inch conduit top and bottom 102 mm or Box 3 16 mm mm DOWN cover open for access 2 11 16 68 mm 2 3 16 56 mm or Box 25.4 mm 3 4 95 mm View Mounting MOUNTING 4 BOX to selection chart for requirements 102 mm square box 2 1 8 54 mm minimum RACO 231 or equal supplied separately box DOWN side view gang cover plate 3 4 19 mm RACO 773 or equal separately gang cover plate View Semi Flush Mounting 9 00 Page 3 Information continued MOUNTING REFERENCE INFORMATION View View mount adapter kit Black Beige must be recessed into wall to 1 1 8 25.4 mm to 29 mm mm mm DOWN cutout must be a of 6 H x 5 W mm by 127 mm 3 4 121 mm 3 4 171 mm 11 16 119 mm box 2 1 8 mm minimum by others the Simplex logo MAPNET and IDNet are either trademarks or registered trademarks of Simplex Time Recorder Co in the U S and or other countries NFPA 72 and Fire Alarm Code are registered trademarks of the National fire Protection Association NFPA Lexan is a registered trademark of General Electric Co 9 00 Skymark Avenue Mississauga Ontario L4W 5K5 and Representatives Throughout the World us on the world wide web at www simplexnet com specifications and other information shown were current as of printing and are subject to change without notice Printed in Canada