Listed FM and Approved II Communicating Devices Zone Adapter Modules ZAMs Interface to Conventional Circuits MAPNET II ZAMs provide an addressable interface conventional fire alarm zone circuit devices Initiating devices Monitor ZAM Notification appliance circuits Signal ZAM Control relays Control ZAM ZAMs are compatible with the following fire alarm control panels when equipped MAPNET II communications 4100 4100U Series fire alarm control panels 4100 Series Universal Transponders 4120 Series Network node fire alarm control panels 4020 Series fire alarm control panels 2120 Communicating Device Transponders II communications can be wired NFPA Style 4 Class B or Style 6 Class A Style 4 Class B communications may be wired tapped or In Out DIP switch address selection listed to Standard 864 MAPNET II zone adapter modules ZAMs provide addressable interface between conventional zone and the host fire alarm control panel ZAMs provide status monitoring and of an initiating device circuit IDC zone and used for circuits with non addressable detectors and other contact closures such as waterflow and tamper or non addressable manual stations Different of Monitor ZAMs are available for two wire IDCs B or Class A and for four wire IDCs with Class B input Each type required a separate 24 VDC input from a listed fire alarm power supply ZAMs supervise and operate 24 VDC notification speakers and telephone circuits Output is up to 2 A 24 VDC or 50 W of 25 VRMS or up to three simultaneously activated phones The signal ZAM is available for either Y Class B or Style Z Class A operation for appliance circuits This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this It is subject to re examination revision and possible cancellation This product not ULC listed or approved by MEA NYC as of document revision date Additional may be applicable contact your local Simplex product supplier for the latest status ZAM ZAM Continued Control ZAMs provide addressable control functions as elevator capture HVAC control pressurization control and damper control The control relay a DPDT contact contact ratings are shown on 4 Specifications Information Connections Means Range Range by MAPNET II to 40 VDC with data 24 VDC required from listed alarm power supply to reference diagrams on 3 and 4 terminals for in out wiring to 12 AWG wire switch 8 position F to 120 F 0 C to 49 C for indoor operation to 85 RH at 86 F 30 C MAPNET II addressable communications are protected by U S Patent No 12 01 Product Selection Current Current Adapter Modules Monitor ZAMs separate 24 VDC power is required Type ZAM Class A Style D Adapter Modules Signal and Control ZAMs separate 24 VDC power is required Current Detector ZAM Class B IDC input ZAM Class B Style B mA 24 VDC ZAM Class A Style Z mA 24 VDC mA 24 VDC ZAM Class B Style Y mA 24 VDC Relay ZAM DPDT Contacts mA 24 VDC mA 24 VDC Current mA 24 VDC Type Typical ZAM Mounting 119 mm Square box 54 mm deep ZAM assembly cover 5 7 16 138 mm cover 4 15 16 125 mm 119 mm extension ring 54 mm deep 12 01 Monitor ZAM Reference Wiring Diagram Tapped IN OUT VDC II B Style B 2 Wire monitor circuit power of line A Style D 2 Wire monitor circuit Wire detector wiring Signal ZAM Wiring Reference VDC Tapped or wiring II B Style Y appliance speakers for reference input audio or phone A Style Z circuit input audio or phone 12 01 Control ZAM Reference Wiring Diagram VDC Tapped or wiring II ZAM Control ZAM Relay Ratings DPDT Contacts Limited Limited Rating A 28 VDC A 28 VDC A 120 VAC DC Voltage must be from a listed Fire Alarm power supply Inductive loads must be properly suppressed C 1 1 1 C 2 2 2 Rating A 28 VDC A 28 VDC A 120 VAC Simplex the Simplex logo and MAPNET II are trademarks of Tyco International Services AG or its affiliates in the U S and or other countries Massachusetts 01441 0001 USA www simplexnet com 2001 Simplex Time Recorder Co DBA TEPG US a Tyco company All rights reserved specifications and other information shown were current as of document revision date and are subject to change without notice 12 01

Related Files