Simplex 2190-9173 2-Point I O Module, Provides Supervised Input & Control Relay Output
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-2190-9173-2-point-i-o-module-provides-supervised-input-control-relay-output-6279035814.pdf |
---|---|
Type | |
Size | 667.32 KB |
Downloads |
Text Preview
UL ULC CSFM Listed FM Approved NYC Acceptance Model 2190 9173 2 Point I O Module Supervised Input and Control Relay Output II Communicating Devices II addressable module providing a input and a control relay output in one package Low power latching relay design allows MAPNET II to supply both data and module power Module uses two sequential addressable points with designation requiring only one address selection For use with Simplex fire alarm control panels that MAPNET II addressable communications UL listed to Standard 864 input point Monitors status of normally open dry contacts for normal open and contact closure Operation reports to the MAPNET II channel as a supervised Individual Addressable IAM control relay Power limited rating 2 A 30 VDC resistive A 30 VDC inductive Non Power limited rating 1 2 A 120 VAC 1 4 A 120 VAC inductive Operation reports to the MAPNET II channel as a Zone Adapter Module ZAM sealed construction Enclosed design minimizes dust infiltration Mounts in standard 4 square electrical box I O Module The 2190 9173 2 Point I O allows a Simplex MAPNET II communication to monitor an input contact closure and control an relay from a single compact module Module is supplied from the MAPNET II communications eliminating the need for separate power wiring Operation The input and output are and operation is controlled by the host panel selection Points may be directly associated each other such as monitoring the status of the function by the contacts or may be programmed for operation This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this It is subject to re examination revision and possible cancellation Accepted for City of New York Department of Buildings MEA35 93E Additional listings may be contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Safety Products TIME RECORDER CO POINT I O INSTR 574 995 2 Point I O Module approximately 1 2 size Applications Package For smoke control applications this provides an efficient package for fan damper with feedback The monitor point connects to a position indicator switch allowing the host panel to the fan damper status with respect to the requested control operation Applications The monitor and control points be applied for a variety of associated or independent Flexible programming abilities at the host can provide the association logic required for a variety of fire or utility operations and by MAPNET II two addresses required per module Information to diagram on page 2 Assignment Addresses Required Connections address setting selects an even address for the input point and next sequential odd number is automatically assigned to the point terminals for in out wiring to 12 AWG wire 0.82 to 3.31 mm2 H x 4 1 8 W x 1 3 8 D mm x 105 mm x 35 mm Material thermoplastic Plate Material metal galvanized Range F to 120 F 0 C to 49 C for indoor operation Range to 93 RH at 100 F 38 C MAPNET II addressable communications are protected by U S Patent No 1 2006 Wiring Reference Distance to Monitored Contacts For internal wiring run no overvoltage protector 500 ft 152m For wiring external to building using a 2081 9044 overvoltage protector 400 ft 122 m overvoltage use when locate where leaves building separately Limited Contact Ratings A 30 VDC resistive transient loads A 30 VDC for inductive loads p f max Limited Contact A 120 VAC resistive suppressed loads A 120 VAC for inductive 0.35 p f max k cid 58 cid 15 1 2 W 4081 9004 733 886 II host panel II Wiring Distances Up to 2500 ft 762 m from host control panel Up to 10,000 ft 3048 m total wiring distance including T taps Refer to Installation Instructions 574 995 and Field Wiring Diagrams and 841 996 for detailed installation information Mounting Information setting under label 2 gang cover plate by others 102 mm square box 54 mm minimum RACO 231 or equal by others I O module Simplex the Simplex logo and MAPNET II are trademarks of Tyco International Services AG or its affiliates in the U S and or other countries 2006 Tyco Safety Products Westminster All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Safety Products Westminster Westminster MA 01441 0001 USA 1 2006