Simplex 3007-9009 6-Zone Control Communicator
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-3007-9009-6-zone-control-communicator-5704613892.pdf |
---|---|
Type | |
Size | 615.19 KB |
Downloads |
Text Preview
Intrusion Control Communicator Simplex 3007 9009 6 Zone Control Communicator accepts to 15 Personal ID Numbers PINs is keypad or remotely pro supports multiple languages and has a wide range features by up to 4 Programmable Keypads Programmable Key User Interface Alpha Display Personal Identification Numbers PINs Listed CSFM approved EMC 89 336 73 23 and Alpha Keypad Support 3007 9009 can use the 3007 9507 or 3007 9501 keypads and the 3007 9502 Alpha Numeric key The 3007 9507 and 3007 9501 provide one LED zone plus system status LEDs that indicate condi such as armed fire alarm and trouble 3007 9502 provides a two line 16 character backlit keys and backlit display The end user adjust the sounder volume and backlight intensity easy two button commands The keypads pro three programmable emergency keys The 3007 is required for system programming LED and keypads can be mixed in the same system Personal ID Numbers PINs system supports fifteen 4 digit personal ID num PINs The PINs can contain any combination of Function Key User Interface labeled function keys eliminate the need for multi commands Functions such as arming disarm and resetting smoke detectors are performed by entering a PIN followed by the function key This provides the new user with easy to follow pro while allowing the expert user quick access the use of cumbersome menu driven formats Mode only requires a PIN to disarm the to silence alarms and to reset the system Arm Feature Arm allows the system to be turned on without use of a PIN A PIN is required to turn the system to silence alarms or to perform system tests Zones 3007 9009 accepts up to 6 input zones that are flexible and can be programmed to provide different functions 1998 Simplex Time Recorder Co All rights reserved 8 98 3 Telephone Numbers system supports two 32 digit telephone numbers a three or four digit account code for each These phone numbers can be individually configured for type of communication format and for the choice of or tone dialing The third phone number is re for remote programming Options LED Keypad Zone LEDs 4 system status LEDs Mounts to a sin gang box Flip top cover for easy instruction guide LED Keypad zone LEDs 8 system status LEDs Sounder volume controlled via simple two button commands Alpha Numeric Keypad two lines of 16 characters The Alpha infor is remotely downloadable and it can be pro by the installer at the keypad Sounder and backlight intensity are controlled with sim two button commands Bell Supervision Module power and supervision for one end of line su bell circuit Connects to alarm output of Indicates trouble condition using a Form connected to one zone Single Phone Line Monitor one phone line Provides a normally open re output that closes upon phone failure individually programmable outputs can be con by alarms access control ground start smoke reset or the control arming state Detector Alarm Verification 3007 9009 can be used in residential fire alarm ap It can be programmed to perform an auto reset on smoke detectors should an alarm If a second alarm occurs within the verification an immediate fire alarm results This reduces false alarms while still providing fast to an alarm Programmability system is completely keypad programmable using 3007 9502 LCD keypad eliminating the need for hand held programmers Programmability Detection System Remote Programming WDSRP for Windows allows the system to remotely programmed using a PC running Windows a standard Hayes modem Running diagnostics systems and bypassing zones can all be ac using an off site computer Remote pro provides a prompt efficient means to customer assistance while reducing the need service visits Protection or part of the programming can be locked so the cannot be changed should someone attempt take over the account Machine Override 3007 9009 has a built in answering machine over function No external hardware is required Digital Communication communicator can interface with most alarm re that are in use today It supports 3 1 3 1 Ext 4 2 SIA Contact ID High Speed 4 9 Personal Di and Pager digital communicator formats The format allows the control to dial a digital pager and leave a numeric message representing the number and event code 1998 Simplex Time Recorder Co All rights reserved 8 98 Specificatons Power Regulated Power Power Voltage Range Standby Battery Available panel Standby Current Output 1 Output 2 Output 3 Zone Inputs Signal Initiating Circuit Type Wire Length 6 Zone Control Communicator Manufactured from 22 Ga cold rolled steel 10.25 H 9.25 W 3.0 D 26.0 cm H 23.5 cm W 7.6 cm D to 120 cid 176 F 0 cid 176 to 49 cid 176 C VAC 20 VA 50 or 60 Hz VDC 800 mA to 14.1 VDC V 7.0 AH VAC and 220 VAC LED Keypad Standby Alarm Current LED Keypad Standby Alarm Current LED Keypad Standby Alarm Current mA mA mA mA Total current for all devices is 500 mA in standby and 800 mA in alarm state switch to ground 500mA Max state switch to ground 500 mA Max Normally Open contacts that switch to 12 V 800 mA circuits End of line resistor 2.21 kOhms supplied zones support dry contact devices such as 4 wire smoke Number of Keypads 22 AWG ft 304.8m for total system Keypads can be up to 1000 ft 304.8 m from the panel when 22 AWG wire is used and only one keypad is to a particular wire run 1998 Simplex Time Recorder Co All rights reserved 8 98 Listings and Approvals CSFM MEA CE UL Listing S5537 CE EMC 89 336 73 23 UL Listing S5187 Information Control Communicator Control Communicator with 3007 9507 Keypad Keypad Numeric Keypad Keypad Supervision Module Phone Line Monitor the Simplex logo are either trademarks or registered trademarks of Simplex Time Recorder Co in the U S and or other countries is a registered trademark of Microsoft Corporation Hayes is a trademark of Hayes Microcomputer Products Inc Massachusetts 01441 0001 USA www simplex com specifications and other information shown were current as of printing and are subject to change without notice 1998 Simplex Time Recorder Co All rights reserved 8 98