Simplex 4002 ESP Application Guide

File Preview
File Preview
Click below to download for free

File Data

Name simplex-4002-esp-application-guide-3462875019.pdf
Type PDF
Size 4.23 MB
Downloads

Text Preview

4002 Fire Alarm Application Guide 1996 Simplex Time Recorder Co specifications Manuals Online were current as of publication are subject other change without notice l 1 56 574 012 1 96 OF CONTENTS Power of Expanded Simplex Programming of This Guide Rules of ESP ESP Programming Function Definitions Signals By Floor Signals By Zone Signal Operation Floor Above Floor Below Fan Damper Operation Relay Control Bypass Control Switch Operation Tamper Zones Operation 1 Stage 2 Operation Zoning Functions Delay and Abort Delay Functions Code Signal Operation Piezo Operation Operation Power Failure Operation Non Default Operation Switch Non Default Operation Point Matrix Zone Grouping Recall Operation Example A Example B Reset Special Operation Stagger Start Operation Successive Coding Sensing Non Interfering and Hints A Suppression Release Equations B Multiple Tamper Switch Zones C Release Delay Door D Non Alarm Monitors E Elevator Recall Program Manuals Online Power of E S P Simplex Programming 4002 Fire Alarm Control switch programmable and resident in the basic system memory an 8 to 32 zone general alarm system with many operating which are unique specific conditions enhanced operation such as selective signalling selective delays non latching PNIS coding or other possible option must be ordered and programmed by local Simplex Branch Office Personnel Expanded Simplex knowledge of computer programming along with this application guide Ref Publication FA4 4j 153 not required to understand E S P Through the use of a program mode 4002 allows for the loading and editing of E S P 8 bit operating codes which reflect the operating is required For a complete understanding of E S P please read the 4002 Programming of this Guide 4002 ESP Application Guide was developed and their ESP programming a guide when you are drafting a software solution for your particular ESP application alarm your specific but is a means to show you the functional power and flexibility of E S P Please use it show step by step examples of common is by no means definitive answer example contains portions of the 4002 System Programming Work Order Sheet M 1378 1 This sheet is be completed by a Simplex Sales Representative the overall project Section 2 shows an ESP checked off Section 3 shows signal circuit information Section 4 shows zoning information and Section ESP In addition each example has portions of the will include a written example of an application Fire Alarm System ESP Programming Sheet This sheet to be completed by the Simplex Technical system set up and check out The actual ESP equations and op codes are shown the sheet Data Base information may or may not appear in examples depending upon the application at hand IMPORTANT Rules of ESP Any control point used in ESP will not be acted upon in any way by the general alarm functions of the 4002 The control point will follow exactly what is specified by the ESP Equation s This can be overridden by using an ESP function equation Refer to the Programming for additional on the use of the function All monitor points are assumed be general alarm points unless otherwise specified Manual for additional the data base mode of ESP Data Points Refer to the Programming and Points Inputs from the serial annunciator RCU and 2120 communicator module are assumed to be System Reset Alarm Silence Trouble Silence

Related Files