Simplex 4003-0001 Voice Control Panel

File Preview
File Preview
Click below to download for free

File Data

Name simplex-4003-0001-voice-control-panel-4930216578.pdf
Type PDF
Size 678.22 KB
Downloads

Text Preview

CSFM Listed FM Approved NYC Acceptance Fire Alarm Controls Voice Alarm Communications Equipment Series Voice Control Panels voice and tone functions to non voice fire control panels Alarms received from a host panel notification appliance NAC activate general alarm operation Manual operation also sends an alarm to a host panel device circuit IDC Earth fault detection is maintained by host panel Compatible with Simplex model 4004 4005 4006 or 4010 Also compatible for retrofit to installed Simplex model 4001 4002 and 4020 features Amplifier provides 75 W 25 VRMS with output microphone with manual controls Four general alarm Class A or Class B NACs Programmable tone and message sequence selection beige cabinet included features Supervised remote microphone with keyswitch control Additional four circuit general alarm NAC card as Class A or Class B for separate control of notification appliances typically strobes Custom digitally recorded messages Available with 240 VAC input voltage listed to Standard 864 non voice fire alarm control panels require the of voice and tone generation Simplex 4003 Control Panels conveniently supply the required Functions include on board tone generation and announcements 75W of amplifier power supervised audio Notification Appliance Circuits and an internal microphone with local control Operation is accessible by opening the locked door and revealing operating switches status the local microphone and the microphone control of the Remote Microphone option is secured by of a keyswitch This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing 6911 0026 196 allowable values and or conditions concerning material presented in this document It is to re examination revision and possible cancellation Accepted for use City of New Department of Buildings MEA35 93E FM approval requires operation with 120 VAC voltage This product was not ULC listed as of document revision date Additional listings be applicable contact Simplex for the latest status Listings and approvals under Simplex Recorder Co are the property of Tyco Safety Products Westminster and Speaker Visible appliances NAC 4 NACs appliances Voice Panel VOICE CONTROL PANEL IDC wiring NAC wiring VDC NAC from Expansion Module 4 NACs control wiring for Expansion Module AND C POWER Alarm Panel Series Voice Control Panel Wiring Reference Continued NAC Option An optional four circuit NAC module be installed in the 4003 to provide power for 24 VDC appliances The expansion NAC is controlled a second NAC input from the host panel Available power depends on audio power used see table on 3 Applications Reference 4003 connects as the end of line device to a NAC and a dedicated IDC from the host fire control panel Alarms from the host panel will a general alarm to the four 4003 NACs to respond common tones and messages as selected The IDC monitors the 4003 for system troubles and selection of the manual evacuation message to send an alarm signal to the host panel panels require a dedicated Monitor ZAM for IDC connection Response Alarm response can be selected to continuous tones follow coded NAC input control or play digitally pre recorded messages with a combination of digitally generated tones Panel Silence and Reset Alarm Signal Silence Alarm Reset are performed at the host panel 2 2007 4003 Product Selection Models VAC 60 Hz input VAC 50 60 Hz input Control Panel with four audio NACs 75 W amplifier internal supply battery charger and microphone mounted in beige B NACs A NACs B NACs A NACs and Options B NACs A NACs Message Set two messages select 4003 0221 for messages from tape or 4003 0222 for messages transcript or 4003 0223 for messages from archive microphone one maximum per 4003 Voice Control Panel trim beige Ah 12 V Battery two required refer to Simplex data sheet S2081 0006 for additional battery information output NAC wiring 22 k 1 2 W ref 733 985 one per connected output NAC input control NAC wiring 10 k 1 2 W ref 733 894 one per connected input NAC Also used for output NAC wiring when connected to models 4001 4002 4004 or 4020 four circuit NAC module use for DC appliances only when used for 24 VDC strobes external synch module 4905 9914 Class B or 4905 9922 Class A see data sheet for details 4020 Applications Reference used to retrofit to an installed Simplex 4020 fire control panel the 4003 can digitally communicate the Remote Unit Interface RUI bus This allows the to monitor the 4003 status and to control tone and selection A dedicated 4020 NAC is connected to 4003 to activate the 4003 output NACs system WALKTEST service testing is in the 4020 will communicate to the 4003 to a voice message response to the device tested example activating addressable manual station 075 an addressable MAPNET II circuit on Channel one yield Channel One Device Seven Five Voice Control Module Features Selection of Audio Tones The desired of tones and messages are determined at the Voice Control Panel The following audio tones are Continuous or coded operation is determined by host fire alarm control panel NAC output Slow Whoop Tone starts at 200 Hz and rises to 830 Hz 2.5 sec recommended for fire alarm use only High Low Tone is a free running signal with a high of 750 Hz for 0.1 sec and a low frequency of Hz for 0.4 sec Horn Tone at 120 beats per minute Horn Tone at 20 beats per minute Chime Tone is a 600 Hz tone with a 1.5 sec delay time for coded or free running signaling Continuous Bell Tone has a fundamental frequency of Hz with prominent harmonics at 700 Hz and 2100 Hz Bell Tone at 60 beats per minute Temporal Code Selection Selectable Temporal Code horn bell whoop and chime tones 1 2 sec on 1 2 off 1 2 sec on 1 2 sec off 1 2 sec on 1 1 2 sec off Control Module Features Cont digitally recorded messages Evacuation An situation has been detected in this building to the nearest exit and leave the building Do re enter the building until directed to by the proper All Clear Your attention please The emergency condition has been cleared You return to your normal activities digitally recorded messages Messages can be reproduced from high quality supplied tapes professionally recorded to requirements or selected from the archived library Convenience Additional internal status indicating LEDs identify status to assist installation and service A service disconnect switch allows the host panel to be without sending an alarm to the 4003 when the control NAC is reported as a trouble at host panel Module Features NACs Standard 4003 panels provide four alarm operation Class B or Class A model audio NACs rated 2A 25 VRMS 50W page 3 for additional NAC ratings Expansion Modules One optional four circuit module Class B or Class A can be field installed provide additional NACs to separately control 24 VDC applia

Related Files