Simplex 4003 Series 4003EC Emergency Voice Communications Equipment, Control Panels, Booster Amplifiers, and associated accessories (E) (D) (C)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4003-series-4003ec-emergency-voice-communications-equipment-control-panels-booster-amplifiers-and-associated-accessories-e-d-c-2163948057.pdf |
---|---|
Type | |
Size | 1.05 MB |
Downloads |
Text Preview
Approved to ANSI UL 864 Control Unit Accessory CAN ULC S527 to FM Standards CSFM Listed digital voice message capability to non voice alarm control panels Remote booster amplifiers are available to expand area or extend to multiple notification areas Activate up to 8 separate messages by direct to fire alarm control panel NACs using the Interface Module option or via supervised to relay contact closures 4003EC Voice Control Panel status alarm system or separate AC trouble is via isolated contact allowing compatibility with a wide range of brand and other fire alarm systems Multiple 4003EC control panels can be interconnected system wide Emergency Communication Systems Notification Systems MNS message using Simplex fire alarm Network node Broadcast live messages using the internal microphone by using a remote microphone up to 18 remote are supported for compatibility with 4 021 01 Unified Facilities Criteria requirements Select from 8 digitally pre recorded messages using control panel switches or controlled from the fire control panel select a pre tone and include a post if desired Custom messages can be ordered separately as chip sets or recorded directly at the panel external equipment new messages override messages control panel details Efficient Class D amplifier design provides 40 W or 70.7 VRMS with power limited output One general alarm Class B audio NAC rated at 40 W be optionally expanded to 4 Class B NACs or 2 A NACs using a Class A B Splitter One general alarm Class B 2 A strobe NAC with output formatted to synchronize either Simplex Cooper Notification Wheelock strobes not mixed Internal push to talk microphone and individual tone message controls for convenient operator Strobe circuit activation is DIP switch selectable for recorded message for microphone use and for input Multiple connections are available for auxiliary output 24 VDC 1 2 A maximum Internal battery charger for up to 12 Ah batteries in or up to 33 Ah batteries in a separate cabinet Removable terminal blocks for easy wiring Beige or red cabinet for surface mounting ULC listed models include low battery cutoff board booster amplifier details Remote booster amplifiers are available with 80 W 2 2 A strobe circuits 160 W and 320 W each an efficient Class D amplifier design Fire Alarm Controls Communication Systems and Mass Systems 4003EC Voice Control Panels Voice Control Panel booster amplifier details Continued Wiring options allow limited or detailed control with to AC power failure and non fire alarm modes Wiring options allow control of non alarm audio when on battery standby and selection of main trouble contacts or AC trouble contacts Booster amplifiers support local connection of paging microphones Removable terminal blocks for easy wiring Beige or red cabinet for surface mounting ULC listed models include low battery cutoff board optional features Upgrade kit to support ten minute message timeout for compatibility with the audible message specifications in UFC 4 021 01 Supervised remote microphones with key switch beige or red for alarm paging black for general Local Operating Console LOC providing enclosed and switch control for the 8 panel messages UFC 4 021 01 requirements for local control Application Note For control from a Wide Area System connect audio 1 VRMS 600 and closure wiring to an available input port on a Remote Microphone Expansion Module Four circuit NAC module Class A or Class B for or control panel allows zone wiring separation Extensive non fire alarm features are available for ringer tone activation telephone page input and music Non fire alarm paging includes zone control and zone adjustments that are bypassed when the panel is alarm mode Models are available for 120 or 240 VAC input Refer to page 4 for CSFM models listed by the California State Fire Marshal CSFM to Section 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this It is subject to re examination revision and possible cancellation This product tested and approved by FM Approvals against both standard FM testing referenced to 72 and ANSI UL Standard 864 9th Edition Additional listings may be applicable your local Simplex product supplier for the latest status 8 2012 Introduction non voice fire alarm control panels require the of voice and tone generation Simplex 4003EC Communications Voice Control Panels supply an extensive feature list Available includes up to 18 remote microphones up to W of distributed remote booster amplifiers and non fire alarm general paging controls Operation requires opening the locked 4003EC door to access the 8 message selection switches local microphone and status indicator LEDs Control Remote Microphones is secured by use of a key switch to remote microphone illustrations on page 6 applications Compatibility with UFC Unified Facilities Criteria for Mass Notification systems for Army Air Force requiring an LOC within 200 ft 61 m of travel and no travel vertically to reach an within a building the Navy and Marines only a single LOC per structure refer to 4 021 01 9 April 2008 for details Add audio operations to existing fire alarm control or non audio panels Connect to fire alarm Network using the Network Integrator NSI to provide network control of a audio panel Allows the fire alarm Network to take control for Communications messages Use of non emergency operations is suspended during standby operation and is overridden during conditions 4003EC Voice Control Module Features Selection of pre and post audio tones Pre message can be selected and if desired the same tone can also selected as a post message tone Tones are switch on board and assigned per message pairs IN1 and message will have the same tone IN3 and IN4 message have the same tone etc tones Temporal Pattern Bell a digitally recorded mechanical sound Temporal Pattern Horn 500 Hz tone Slow Whoop a slowly ascending tone Wail ascends then descends between 600 to 940 Hz Chime Tone Announcement Chime High Low with high frequency of 750 Hz for 100 ms low frequency of 500 Hz for 400 ms GSA Tone continuous 2000 Hz Fast Whoop a quickly ascending tone Horn Tone at 120 beats per minute Horn Tone at 20 beats per minute Bell Tone at 60 beats per minute Pattern evacuation signal reference sec on 1 2 sec off 1 2 sec on 1 2 sec off 1 2 sec on sec off Standard Messages and Input Priority List custom messages and priorities are available see Note below push to talk microphone for on site messages input from one or multiple remote microphones or from a separate audio input with voltage as 1 25 or 70.7 VRMS NOTE Multiple microphones require use of 4003 9834 Microphone Modules and each remote microphone input is prioritized by electrical wiring sequence Operation requires a separate contact closure to enable the Auxiliary input Priority Message Type Voice Message Intruder Male Threat Male Clear Attention Attention This is a fire alarm Exit the building Attention Attention There is an armed intruder in the building take cover have received a bomb threat The police have been notified and we are a search of the building perimeter Please standby for further severe weather condition has been reported Please go directly to the nearest area and wait for further instructions please Severe weather has been re