Simplex 4004-9803 Relay Module Installation Instructions

File Preview
File Preview
Click below to download for free

File Data

Name simplex-4004-9803-relay-module-installation-instructions-9687302145.pdf
Type PDF
Size 779.72 KB
Downloads

Text Preview

Cautions and Warnings Relay Module Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of the for shipping damage If damage is apparent immediately file a claim with carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives HAZARD Static electricity can damage components Therefore as follows Ground yourself before opening or installing components use the 553 484 Control Kit Keep uninstalled component wrapped in anti static material at all times FREQUENCY ENERGY This equipment generates uses and can radio frequency energy and if not installed and used in accordance with the manual may cause interference to radio communications It has been and found to comply with the limits for a Class A computing device to Subpart J of Part 15 of FCC Rules which are designed to provide protection against such interference when operated in a commercial Operation of this equipment in a residential area may cause in which case the user at his own expense will be required to take measures may be required to correct the interference publication shows how to install the 4004 9803 Relay Module 566 058 into 4004 Fire Alarm System Only one of these modules can be installed in a 4004 Alarm System The 4004 Fire Alarm System supports either a Relay Module or 4004 9810 Internal DACT or or 9829 City Circuit Module reference information on installing the relay module refer to the Contractor Termination Label 519 698 on the 4004 Door Panel This Publication publication covers the following topics Page Module Parts 1 742 311 Service Parts List Number Module Harness Screws 2000 Simplex Time Recorder Co Westminster MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice B Relay Module 4004 9803 Relay Module connects with a ribbon harness 733 952 to the board of the 4004 Fire Alarm System The relay module provides to external devices through three dry relay contacts which provide for Supervisory and Trouble reporting See Figure 1 below for connector applications requiring relay contact outputs for Alarm Supervisory and the 4004 9803 Relay Module converts the open collector City DACT into individual relay outputs that can be jumper selectable as either Open NO or Normally Closed NC relay output is rated at 2A 32 VDC maximum and is for controlling power a power limited fire alarm power supply listed for the application The Alarm activates on an alarm condition until reset The Supervisory relay activates on supervisory condition until clear The Trouble relay activates on a trouble until clear Each relay has an LED to indicate its ON OFF status The relay module has dry relays There are no markings on board or terminal block P1 P2 and P3 are shown in Normally Closed position 1 of P1 P2 and P3 is the pin on the relay module 1 ALARM 1 4004 9803 Relay Module the Relay Module the information in Table 2 to set the jumper positions for relays K1 K2 and to utilize Normally Open NO Normally Closed NC contact positions 2 Jumper Positions for NO and NC Relay Contacts Open Closed K1 Alarm K2 Supervisory K3 Trouble to P1 3 to P2 3 to P3 3 to P1 2 to P2 2 to P3 2 relay module circled in Figure 2 installs into a hardware slot located to the of the 4004 System Board Use Steps 1 through 9 to mount the relay module Disconnect battery power from the 4004 System Board At the breaker disconnect AC power from the 4004 System Board Ensure the jumpers on the module are set to the proper position before With TB1 of the relay module in the bottom position align the four holes in relay module with the corresponding four threaded standoffs on the Utilizing the four supplied TORX screws 430 205 secure the relay on the bracket to the right of the 4004 System Board Terminate all wiring to their appropriate connectors Using the ribbon harness connect it from P4 of the relay module to P5 of the System Card refer to Figure 2 for the location of P5 The Ribbon Harness is keyed to the LEFT to ensure proper orientation At the breaker apply AC power to the FACP Apply battery power to the FACP Program the relay card into the system board by using the panel programming located on the inside front door of the 4004 unit Follow the procedures programming a city or DACT card Program 9 1 2 4004 9803 Relay Module Location B

Related Files