Simplex 4004 Fire Alarm I O Cards ™ Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4004-fire-alarm-i-o-cards-installation-instructions-8431029765.pdf |
---|---|
Type | |
Size | 607.88 KB |
Downloads |
Text Preview
and Warnings Fire Alarm I O Cards Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of the for shipping damage If damage is apparent immediately file a claim the carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives HAZARD Static electricity can damage components Therefore as follows Ground yourself before opening or installing components use the 553 484 Control Kit Keep uninstalled component wrapped in anti static material at all times FREQUENCY ENERGY This equipment generates uses and can radio frequency energy and if not installed and used in accordance with instruction manual may cause interference to radio communications It has tested and found to comply with the limits for a Class A computing device to Subpart J of Part 15 of FCC Rules which are designed to provide protection against such interference when operated in a commercial Operation of this equipment in a residential area may cause in which case the user at his own expense will be required to take measures may be required to correct the interference publication shows how to install and configure the 4004 Fire Alarm Cards which are listed below 4004 9802 2 Point IDC Low Current Expander Card Part No 565 575 4004 9804 4 Point IDC Low Current Expander Card Part No 565 589 4004 9822 2 Point IDC Relay Base High Current Card Part No 565 612 4004 9824 4 Point IDC Relay Base High Current Card Part No 565 613 4004 9806 Class A Adapter Card Part No 565 585 or 565 789 4004 9808 Annunciator Interface Card Part No 565 579 this Publication publication discusses the following topics Page IDC Card s Installation Card Installation A Adapter Card Installation 1998 Simplex Time Recorder Co Gardner MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice A I O Cards Installation Installation IDC Card s Power down the 4004 before installing an I O card the card from the packing material and use the appropriate paragraph to install any of the above cards into the 4004 panel For all wiring use the Field Wiring Diagram 841 992 Possible locations for the are shown inside the 4004 door panel on the Contractor Wiring Label 519 698 The label illustrates the card to card connections disconnect switch locations and the programming information necessary to the added cards to the system 2 Point and 4 Point IDC card locations are interchangeable Four installations require a 2 point IDC card and six or eight circuit require a 4 point IDC card a 2 Point or 4 Point IDC card as follows 2 Point IDC Card Low or High Current Carefully slide the 2 IDC expansion card P1 connector into the J3 connector of the card or the J3 connector of the 4 Point IDC expansion card 4 Point IDC Card Low or High Current Carefully slide the 4 IDC expansion card P1 connector into the J3 connector of the card or the J2 connector of the 2 Point IDC expansion card Secure the card s to the 4004 mounting plate using the four supplied No 6 screws for each IDC expansion card Before programming the added IDC card s ensure that the zone switches are in the position If open circuit on respective AUX output is desired clip the appropriate IDC Card IDC Card Zone 1 Zone 2 Zone 1 Zone 2 Zone 3 Zone 4 The low current 2 Point 4 Point IDC card s use a 6.8k ohm End of Line EOLR for Class B operation The high current 2 Point 4 Point card s use a 3.3k ohm EOLR for Class B operation All IDC card can be converted to Class A operation by adding a Class A card see installation instructions on page 3 Power up the 4004 system and program the IDC card using the instructions located on the Contractor Termination Wiring inside the 4004 door panel on next page I O Cards Installation Interface Card A Adapter Card and secure the card to the 4004 mounting plate using the four No 6 Torx screws Connect cable harness 733 885 from Annunciator Interface card J1 to system card P4 EOLR resistors for all seven I O points as shown on the 841 992 Wiring Diagram Power up the 4004 system and program the Annunciator Interface card the programming instructions located on the Contractor Termination Label inside the 4004 door panel A Cards 565 585 old or 565 789 new Remove the two bottom and loosen the top two No 6 Torx screws securing 4004 mounting plate to the Back Box Be careful not to damage wiring when removing or mounting plate to from back box to install A Card s If necessary disconnect and label conductors Lay mounting plate on a non static free table when installing Class A Carefully remove the mounting plate from the back box by lifting the plate up and gently pulling it left past the locking tab and forward release the mounting plate The Class A card piggybacks to the J1 and or J2 connectors on the System connector J1 on the 2 Point IDC Card and connector J1 and or J2 on 4 Point IDC Card through the pre punched slots on the back of the plate The Class A card connected to the system card NAC circuit illustrated in Figure 1 Connect the card s in the desired location s by first inserting the supplied header into the J1 connector component side of the Class A old Install the three supplied stand offs on the back of the plate then plug the Class A card s via the 8 position header into connector of the selected IDC or NAC with TB1 of the class A card s top and facing the back of the mounting plate Mount and secure the using the three supplied No 6 Torx Screws new Install the two supplied stand offs on the back of the plate then plug the Class A card s via the 8 position header into connector of the selected IDC or NAC with TB1 of the class A card s top and facing the back of the mounting plate Mount and secure the using the two supplied No 6 Torx Screws on next page Installation A Adapter Card continued The 565 789 Class A Adapter card has no jumper settings end of line EOLR are mounted on the terminal block with the return Refer to the Field Wiring Diagram 841 992 Rev F or later detailed wiring information settings for the 565 585 Class A Adapter card s for IDC and NAC are as follows Configuration Card 565 573 IDC Circuit Low Current IDC Card 565 575 Low Current IDC Card 565 589 High Current IDC Card 565 612 High Current IDC Card 565 613 Card 565 573 NAC Circuit Setting to P1 4 P2 2 to P2 4 to P1 4 P2 2 to P2 4 to P1 4 P2 2 to P2 4 to P1 3 P2 1 to P2 3 and secure the mounting plate to the back box using the four No 6 screws Power up the 4004 System No programming is necessary when installing A Adapter cards A CARD or 565 789 CARD NOTE PLATE PLATE This screw and stand off are not used when mounting the new Class A Adapter Card 1 Class A Adapter Card Installation 1998 Simplex Time Recorder Co Gardner MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice A