Simplex 4004R Suppression Releasing Panel Sheet

File Preview
File Preview
Click below to download for free

File Data

Name simplex-4004r-suppression-releasing-panel-sheet-0317294856.pdf
Type PDF
Size 935.81 KB
Downloads

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Control Fire Alarm Systems 4004R Suppression Releasing Panel for Automatic Deluge and Preaction Sprinkler Control alarm control panel designed specifically for release operation with Four initiating device circuits IDCs Two notification appliance circuits NACs Two releasing appliance circuits RACs Two special purpose monitor inputs SPMs that accept release request and manual abort request for Release systems and waterflow and supervisory Preaction or Deluge systems Three auxiliary relays with selectable functions Easily selected activity timing options release operation includes Automatic extinguishing release Deluge and preaction sprinkler system release Dual or single hazard area protection Combined agent release and preaction operation are selectable for cross zoning or for activation a single detection input Short circuit RAC supervision Compatible with Listed Approved 24 VDC or 12 VDC series connected actuators Escalation of Events Single Audible Appliance Tone Stage 1 activates or 20 bpm March Time pattern Stage 2 120 bpm March Time pattern to indicate timer active Release activates On Steady to release timer expired and actuator is activated Dual Audible Appliance Control Single Hazard 2 provides a third NAC for dedicated Stage 1 Bell NACs 1 2 indicate release as On Steady interface provides Status LEDs per circuit for Alarm Trouble and where appropriate Acknowledge Alarm Silence and System Reset Operating mode selection and timer selections when in mode system components Coil supervision module 2081 9046 one per RAC Maintenance Switch one per RAC Abort Switch to UL Standard 864 and ULC Standard S527 Dedicated for Suppression Release 4004R Release Panels provide conventional fire alarm circuits and are equipped with the features required a wide variety of single or dual hazard suppression release Capabilities include automatic extinguishing release and deluge and preaction sprinkler control Requires Software Revision 4.01 or higher discharge path NAC NAC SUPERVISION MODULE 2 AMP 2081 9046 INSTRUCTIONS 574 437 REV 1 4 SEPARATION POWER LIMITED AND NONPOWER YEL BLK WIRING CODE T IME RECORDER CO GARDNER MA USA Switch SUPPRESSION DISABLE 1 SUPPRESSION ABORT AND HOLD 2 1 1 2 1 1 2 3 4 Silenced Trouble Release 5 Trouble Release 6 Trouble 1 Trouble 2 Trouble 1 Trouble 2 Trouble Released Fault Active Power Disconnect AND C POWER 2 3 and 4 2 Suppression Release Panel Suppression Release Panel System Reference Drawing Continued Flexible I O Capabilities Four IDCs allow for either separately monitored zones or two cross zoned Two SPMs allow dedicated manual inputs for or abort for waterflow and supervisory or and pressure depending on system type Two appliance circuits RACs supervise to the coils and activate the actuators when required The NACs and the three panel auxiliary relays provide condition information Program Selections The operator panel has a mode that allows selection of panel operation and detailed operating selections using an easily sequential programming operation Log The last 50 events are stored in memory This information is accessed by a technician computer to the service port is also used to set the date and time Feature Description Operator Panel The operator panel has alarm and status indicating LEDs for each input and output through the locking cabinet door refer to diagram page 4 Unlocking the door provides access to the Alarm Silence and System Reset switches This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document It is subject to re examination revision and possible cancellation listings may be applicable contact your local Simplex product supplier for the status Listings and approvals under Simplex Time Recorder Co are the property of Safety Products Westminster 9 2008 Class B Releasing Appliance Circuits RACs Rated A each these circuits are dedicated to operating release actuators RAC cutout timing is selectable as no 45 seconds or 1 3 3.5 4 5 6 7 21 25 34 44 64 minutes For bell horn strobe single hazard RAC 2 functions as a third NAC NAC 3 Power Output Two sets of output terminals are one for continuous operation and the other for operation rated for 750 mA combined terminals are provided for 4 wire smoke power Panel Auxiliary Relay Outputs Three relay are available selectable as normally open or closed rated 2 A 30 VDC 0.35 p f inductive Relay 1 Trouble is energized when Normal and is with a common Trouble condition Relays 2 and 3 respond differently depending on the type and whether single or dual hazard Typical are Single Hazard Operation Aux Relay 2 is the Alarm relay Aux Relay 3 can be selected to pre discharge release time delay started supervisory waterflow or pressure switch relay on the system type Dual Hazard Operation Aux Relay 2 is for Hazard 1 common Alarm Aux Relay 3 is for Hazard Area 2 Alarm Supply and Battery Charger During alarm the supply provides 3 A at 25.5 VDC filtered and The temperature compensated battery charger 27.5 VDC for charging batteries suitable for up to hour standby and 10 minutes of alarm External battery and cabinets can be used for more battery backup Panel Feature Description Continued to specifications on page 6 for more information Class B IDCs provide coverage for either two areas or four separately zoned areas IDCs are of supporting up to 30 Simplex current limited detectors or electronic heat detectors see list on 2 as well as manual stations and other compatible closure initiating devices IDCs are capable of A operation with an optional adapter module and can programmed as Style C short or open initiates a trouble use with current limited devices only Single hazard agent applications monitor pressure switches with IDC 3 tamper switches with IDC 4 Class B Special Purpose Monitoring Circuits SPMs dedicated for manual release or abort waterflow and or release abort and pressure depending on type Inputs are normally open switches An abort stops release while activated and upon deactivation release operation occurs after a selectable time delay release inputs override abort switches and activate release after selectable delays of from 0 to 30 seconds in second increments For Dual Hazard applications current abort operation is required SPMs are programmable Style C and capable of Class A operation with the optional module Class B NACs are provided for reverse polarity appliance operation each rated 2 A Class A is available with the optional adapter module operation is selectable per application Synchronized operation requires a separate 4905 Series Strobe Module see product selection below and continuous steady on non coded input from the NAC Product Selection Control Panels Listings Beige UL ULC CSFM FM Red UL ULC CSFM FM Modules NYC Releasing Panel operates with AC input of 120 220 230 240 VAC Hz auto select includes four IDCs two NACs two SPMs two RACs auxiliary relays and 3 A power supply with battery charger cabinet and door Ah batter

Related Files