Simplex 4005 Programming Sheets
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-4005-programming-sheets-9304267581.pdf |
---|---|
Type | |
Size | 856.91 KB |
Downloads |
Text Preview
4005 Fire Alarm Sheets the following sheets to record ALL 4005 Fire Alarm programming NAME CONTACT NO SYSTEM PROGRAMMING NO REP 1 2 AS REQUIRED AS REQUIRED GENERAL ALARM ALARM VERIFICATION WATERFLOW SPRINKLER SUPERVISION SIGNAL CUTOUT O 60 MINS SIGNAL SILENCE O 60 MINS SIGNAL OPERATION ONE TIME MARCH TIME CODE CODE ENERGY C POLARITY SELECTIVE SIGNAL OPERATION SELECTIVE RELAY CONTROL SELECTIVE DOOR HOLDER RELAY CONTROL SELECTIVE SWITCH OPERATION CUSTOM FAN DAMPER RELAY CONTROL CROSS ZONING NON ALARM MONITOR POINTS NON LATCHING MONITOR POINTS TRACKING CITY CONNECTION ONE AC POWER FAIL CONTROL ANNUNCIATOR REQUIREMENTS AS REQUIRED LIST QUANTITY ON SYSTEM POINT TYPE ELEVATOR RECALL ALT FLOOR OPERATION RCU SWITCH NON DEFAULT OPERATION SCU RCU MEMORY POINT MATRIX ZONE GROUPING 1996 Simplex Time Recorder Co Gardner MA 01441 0001 specifications other were current as of publication are subject change without notice Manuals Online 1 96 Manuals Online PANEL PROGRAMMING MENU POINT CARDS SMPL OPTIONS LEVELS CFIG T CFIG 2 Programming Menu Structure Edit Point Point Type Custom Label 40 Characters l Modes valid for RCU SCU annunciators and 8 point only Switch control Modes mode point used by SMPL all points global all Fire alarms all Supervisory alarms all Trouble alarms a system reset an alarm silence ON OFF point button track point button hold point point OFF disable enable point l List Contents Manuals Online For list pseudos operator can add points or delete points from the list LED tracking modes mode point used by SMPL the Fire alarm state the Supervisory alarm state the Trouble alarm state the Disable state the ON state the OFF state Manuals Online 3 Input Operators Table operator AND operator OR oDerator 4 Output Operators Table ON OFF ON OFF MARCH Point On Point Off Point On Point Off Point Output Code Output Code Slow March Output Code EQUATIONS the following to record your SMPL equations Manuals Online Manuals Online System Options Time Date Format 12 Hour 24 Hour Active Point Reminder SUPV TBL sounds every 8 hours YES NO Alarm Silence Reset Timer O 60 Minutes 0 Alarm Signal Cutout Time O 60 Minutes 0 with no cutout Doorholder drop on Alarm O 60 Seconds 0 Doorholder drop on AC loss O 60 Minutes 5 Audible Signal Operation Steady Visible Signal Operation Steady Enable City Circuit 1 YES NO Enable City Circuit 2 YES NO ON OFF March Time March Time March Time March Time Expansion Power Supply Values Access Levels Passcodes CFIG Clear Edit Buffer to CFIG Manuals Online Manuals Online Table 7 to record your Notification Appliance Circuit NAC Relay point types 7 Circuits and Descriptions Relay Point Type NACslRelays Maximum 8 lists available Signal point types 8 Point Types Fire Signal On Silence RSIGNAL Fire Signal On Reset Trouble On Clear Trouble On ACK Visual On Silence Visual On Reset Signal Circuit WaterFlow RWATER WaterFlow Silence Reset Sprinkler Supervisory Signal Elevator Capture primary ALTERN Elevator Capture alternate AHU Relay AHU On Relay AHU Off Relay DHOLDER Door Holder Manuals Online Manuals Online Table 10 to record your Custom Labels for each zone The available characters are as follows Digits Alpha Punctuation and a z 10 Labels Manuals Online Manuals Online